List-mode quantitative joint reconstruction of activity and attenuation maps in Time-of-Flight PET

被引:1
|
作者
Hemmati, Hamidreza [1 ,2 ]
Kamali-Asl, Alireza [3 ]
Ghafarian, Pardis [4 ,5 ]
Rahmim, Arman [6 ,7 ]
Zaidi, Habib [8 ,9 ,10 ,11 ]
Ay, Mohammad Reza [1 ,12 ]
机构
[1] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[2] Univ Calif Davis, Dept Biomed Engn, Davis, CA USA
[3] Shahid Beheshti Univ, Dept Med Radiat Engn, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Masih Daneshvari Hosp, NRITLD, Chron Resp Dis Res Ctr, Tehran, Iran
[5] Shahid Beheshti Univ Med Sci, Masih Daneshvari Hosp, PET CT & Cyclotron Ctr, Tehran, Iran
[6] Univ British Columbia, Dept Radiol & Phys, Vancouver, BC, Canada
[7] BC Canc, Res Ctr, Dept Integrat Oncol, Vancouver, BC, Canada
[8] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[9] Univ Geneva, Neuroctr, Geneva, Switzerland
[10] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[11] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
[12] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
基金
瑞士国家科学基金会; 美国国家科学基金会;
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Medical-image reconstruction methods and algorithms; computer-aided diagnosis; Multi-modality systems; IMAGE-RECONSTRUCTION; SIMULATION;
D O I
10.1088/1748-0221/18/09/P09041
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Quantitative PET imaging requires accurate determination of patient-specific attenuation maps, which remains challenging on hybrid PET/MRI systems owing to the lack of a direct relationship between MR image intensity and attenuation coefficients. The aim of the present study is to develop a list-mode based algorithm for accurate and robust attenuation correction of PET data using time-of-flight (TOF) emission information. We analyze and address the challenges of list-mode emission-based maximum-likelihood joint estimation of activity and attenuation (LM-MLAA) in state-of-the-art PET imaging. The proposed method exploits a rapid on-the-fly system matrix calculation algorithm based on elliptic integrals while updating the attenuation map from accumulating list-mode coincidences to achieve accelerated image reconstruction. The scattering compensation is incorporated inside it using an iterative approach in such that the current estimation of attenuation map used on a course grid sampling scattering points to make an estimate of scattering. The performance of the proposed LM-MLAA approach was evaluated on Monte Carlo simulations of a phantom at different time resolutions. The contrast and noise for hot and cold regions on reconstructed images at different time resolutions were analysed. The estimated attenuation map exhibits resilience against noise, effectively eliminates high-frequency cross-talk even in the absence of prior information on attenuation coefficients, and enables discrimination among different anatomical regions in the reconstructed image. The error in the mean estimated attenuation coefficients after 50 iterations was similar to 2% in water and similar to -14% in Teflon regions for TOF resolutions corresponding to those of most current commercial PET systems (similar to 500 ps). The proposed LM-MLAA framework can be used for joint reconstruction of activity and attenuation maps from list-mode emission data as standalone or a complementary approach to existing in multimodality imaging such as PET/MRI, where direct measurement attenuation maps is not possible.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Joint estimation of activity, attenuation and motion in respiratory-self-gated time-of-flight PET
    Elhamiasl, Masoud
    Jolivet, Frederic
    Rezaei, Ahmadreza
    Fieseler, Michael
    Schaefers, Klaus
    Nuyts, Johan
    Schramm, Georg
    Boada, Fernando
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (07):
  • [32] Efficient Rendering of Regions of Response in List-Mode Reconstruction for PET
    Sportelli, Giancarlo
    Ortuno, Juan E.
    Santos, Andres
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4219 - 4221
  • [33] List-mode reconstruction in 2D strip PET
    Bialas, Piotr
    Kowal, Jakub
    Strzelecki, Adam
    Bednarski, Tomasz
    Czerwinski, Eryk
    Giergiel, Krzysztof
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Korcyl, Grzegorz
    Kowalski, Pawel
    Kozik, Tomasz
    Krzemien, Wojciech
    Molenda, Marcin
    Moskal, Ines
    Moskal, Pawel
    Niedzwiecki, Szymon
    Palka, Marek
    Pawlik, Monika
    Raczynski, Lech
    Rudy, Zbigniew
    Salabura, Piotr
    Sharma, Neha G.
    Silarski, Michal
    Slomski, Artur
    Smyrski, Jerzy
    Szymanski, Konrad
    Wislicki, Wojciech
    Witkowski, Piotr
    Zielinski, Marcin
    Zon, Natalia
    BIO-ALGORITHMS AND MED-SYSTEMS, 2014, 10 (01) : 9 - 12
  • [34] List-mode reconstruction for TOF PET by estimating annihilation positions
    Kao, Chien-Min
    Kim, Heejong
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2402 - 2406
  • [35] The SNR of time-of-flight positron emission tomography data for joint reconstruction of the activity and attenuation images
    Nuyts, Johan
    Defrise, Michel
    Morel, Christian
    Lecoq, Paul
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (01):
  • [36] Accelerated Regularised List-Mode PET Reconstruction Using Subset Relaxation
    Spangler-Bickell, Matthew G.
    Deller, Timothy
    Jansen, Floris
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [37] Simultaneous emission and attenuation reconstruction in time-of-flight PET using a reference object
    Pablo García-Pérez
    Samuel España
    EJNMMI Physics, 7
  • [38] Simultaneous emission and attenuation reconstruction in time-of-flight PET using a reference object
    Garcia-Perez, Pablo
    Espana, Samuel
    EJNMMI PHYSICS, 2020, 7 (01)
  • [39] Randoms correction for gamma camera based PET list-mode reconstruction
    Vandenberghe, S
    D'Asseler, Y
    Koole, A
    Bouwens, L
    Van de Walle, R
    Lemahieu, I
    Dierckx, RA
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2031 - 2035
  • [40] An Efficient Implementation of PET Image Reconstruction from List-Mode Data
    Zhang Bin
    Shan Bao-ci
    Yun Ming-kai
    Zhao Shu-jun
    2012 INTERNATIONAL WORKSHOP ON INFORMATION AND ELECTRONICS ENGINEERING, 2012, 29 : 3403 - 3407