Estimation of radiation dose associated with bone SPECT/CT and establishing local diagnostic reference levels using size-specific dose estimate

被引:3
|
作者
Alrehily, Faisal [1 ,2 ]
Alshamrani, Abdullah F. [1 ]
机构
[1] Taibah Univ, Coll Appl Med Sci, Dept Diagnost Radiol Technol, Madinah, Saudi Arabia
[2] Taibah Univ, Coll Appl Med Sci, Bldg 115,Prince Naif Rd, Madinah 42353, Saudi Arabia
关键词
SPECT; CT; CTDIvol; DLP; SSDE; LDRL; Effective dose; NATIONAL-SURVEY; CT; SSDE;
D O I
10.1016/j.jrras.2023.100527
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Single-photon emission computed tomography (SPECT) and X-ray computed tomography (CT) is used to di-agnose and monitor the skeletal system. However, due to the combination of injected activity and CT radiation dose, its usage is linked to an increase in patient radiation exposure. This study aims to estimate the radiation dose received by patients while undergoing bone SPECT/CT and to establish its local diagnostic reference level (LDRL). In this retrospective study, data from 30 patients who had undergone bone scans were obtained from two hospital imaging devices. The effective doses (E) of the radiopharmaceutical agent and CT components were calculated. Furthermore, the patients' anteroposterior thickness at the midline and lateral widths were measured from their CT images to determine the size-specific dose estimate (SSDE). The mean age of the patients was 53.53 +/- 16 years. They were administered an injection activity of 740 MBq of 99mTc-Methyl diphosphonate for SPECT, yielding an E of 2.78 mSv. The mean CTDIvol, DLP, SSDE, and E values for the CT component were 8.76 +/- 3.25 mGy, 350 +/- 138 mGy cm, 13 +/- 4 mGy, and 4.90 +/- 1.94 mSv, respectively. Patients received a combined dose of 7.68 mSv from the radiopharmaceuticals and CT. The proposed LDRL for SPECT was comparable to international DRLs, but the CT LDRL was slightly higher. An SSDE-based LDRL is proposed. Moreover, the overall patient dose can be reduced even further by optimizing the injected activity and CT imaging factors.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] PATIENTS DOSE ESTIMATION IN CT EXAMINATIONS USING SIZE SPECIFIC DOSE ESTIMATES
    Choudhary, Neha
    Rana, Bhupendra Singh
    Shukla, Arvind
    Oinam, Arun Singh
    Singh, Narinder Paul
    Kumar, Sanjeev
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (02) : 256 - 262
  • [42] Radiation doses and size-specific dose estimate from CT brain examinations according to head sizes in a tertiary hospital in Malaysia
    Kayun, Zunaide
    Karim, Muhammad Khalis Abdul
    Harun, Hanif Haspi
    Shaari, Abdul Halim
    Mahmud, Rozi
    Hamid, Hamzaini Abdul
    Sabarudin, Akmal
    Chew, Ming Tsuey
    RADIATION PHYSICS AND CHEMISTRY, 2021, 189
  • [43] Estimation of radiation dose and establishment of local diagnostic reference levels for computed tomography of head in pediatric population
    Priyanka
    Kadavigere, Rajagopal
    Sukumar, Suresh
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (05) : 983 - 991
  • [44] Diagnostic Reference Levels of CT Radiation Dose in Whole-Body PET/CT
    Jallow, Ngoneh
    Christian, Paul
    Sunderland, John
    Graham, Michael
    Hoffman, John M.
    Nye, Jonathon A.
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (02) : 238 - 241
  • [45] AUTOMATIC ACQUISITION OF CT RADIATION DOSE DATA: USING THE DIAGNOSTIC REFERENCE LEVEL FOR RADIATION DOSE OPTIMIZATION
    Nakada, Yoshihiro
    Okuda, Yasuo
    Tsuge, Tatsuya
    Suzuki, Jyunichi
    Sakamoto, Hiroshi
    Yamamoto, Tsuyoshi
    Konishi, Yasuhiko
    Tsujimoto, Takeshi
    Nishiki, Shigeo
    Satoh, Toshimitsu
    Aoyama, Nobukazu
    Morimoto, Kyohei
    Aita, Masamichi
    Yamashita, Yusuke
    Yoshitake, Takayasu
    Mukai, Masami
    Yokooka, Yuki
    Yokohama, Noriya
    Akahane, Keiichi
    RADIATION PROTECTION DOSIMETRY, 2018, 181 (02) : 156 - 167
  • [46] LOCAL DRLS FOR PAEDIATRIC CT EXAMINATIONS BASED ON SIZE-SPECIFIC DOSE ESTIMATES IN KERMANSHAH, IRAN
    Mohammadbeigi, Ahmad
    Khoshgard, Karim
    Haghparast, Abbas
    Eivazi, Mohammad Taghi
    RADIATION PROTECTION DOSIMETRY, 2019, 186 (04) : 496 - 506
  • [47] Comparison between Deff and Dw approaches for estimation of size-specific dose in paediatric CT imaging
    Abdulkadir, Muhammad Kabir
    Shuaib, Ibrahim Lutfi
    Nasirudin, R. A.
    Samsudin, Ahmad Hadif Zaidin
    Osman, Noor Diyana
    RADIATION PHYSICS AND CHEMISTRY, 2022, 198
  • [48] Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations
    Hamza Sulemana
    Abdul Nashirudeen Mumuni
    Izre-deen Osman Mohammed Abubakari
    Egyptian Journal of Radiology and Nuclear Medicine, 55 (1):
  • [49] How to Appropriately Calculate Effective Dose for CT Using Either Size-Specific Dose Estimates or Dose-Length Product
    Brady, Samuel L.
    Mirro, Amy E.
    Moore, Bria M.
    Kaufman, Robert A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (05) : 953 - 958
  • [50] Evaluation of a new predictive equation for automated calculation of size-specific dose estimate (SSDE) in CT imaging
    Osman, N. D.
    Abdulkadir, M. K.
    Shuaib, I. L.
    Nasirudin, R. A.
    RADIOGRAPHY, 2024, 30 (01) : 237 - 244