Estimation of radiation dose associated with bone SPECT/CT and establishing local diagnostic reference levels using size-specific dose estimate

被引:3
|
作者
Alrehily, Faisal [1 ,2 ]
Alshamrani, Abdullah F. [1 ]
机构
[1] Taibah Univ, Coll Appl Med Sci, Dept Diagnost Radiol Technol, Madinah, Saudi Arabia
[2] Taibah Univ, Coll Appl Med Sci, Bldg 115,Prince Naif Rd, Madinah 42353, Saudi Arabia
关键词
SPECT; CT; CTDIvol; DLP; SSDE; LDRL; Effective dose; NATIONAL-SURVEY; CT; SSDE;
D O I
10.1016/j.jrras.2023.100527
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Single-photon emission computed tomography (SPECT) and X-ray computed tomography (CT) is used to di-agnose and monitor the skeletal system. However, due to the combination of injected activity and CT radiation dose, its usage is linked to an increase in patient radiation exposure. This study aims to estimate the radiation dose received by patients while undergoing bone SPECT/CT and to establish its local diagnostic reference level (LDRL). In this retrospective study, data from 30 patients who had undergone bone scans were obtained from two hospital imaging devices. The effective doses (E) of the radiopharmaceutical agent and CT components were calculated. Furthermore, the patients' anteroposterior thickness at the midline and lateral widths were measured from their CT images to determine the size-specific dose estimate (SSDE). The mean age of the patients was 53.53 +/- 16 years. They were administered an injection activity of 740 MBq of 99mTc-Methyl diphosphonate for SPECT, yielding an E of 2.78 mSv. The mean CTDIvol, DLP, SSDE, and E values for the CT component were 8.76 +/- 3.25 mGy, 350 +/- 138 mGy cm, 13 +/- 4 mGy, and 4.90 +/- 1.94 mSv, respectively. Patients received a combined dose of 7.68 mSv from the radiopharmaceuticals and CT. The proposed LDRL for SPECT was comparable to international DRLs, but the CT LDRL was slightly higher. An SSDE-based LDRL is proposed. Moreover, the overall patient dose can be reduced even further by optimizing the injected activity and CT imaging factors.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] PATIENT DOSE SURVEY BASED ON SIZE-SPECIFIC DOSE ESTIMATE AND ACCEPTABLE QUALITY DOSE IN CHEST AND ABDOMEN/PELVIS CT EXAMINATIONS
    Mehdipour, Ali
    Parsi, Masoumeh
    Khorram, Faezeh-Sadat
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (02) : 176 - 182
  • [32] Size specific dose estimate (SSDE) for estimating patient dose from CT in myocardial perfusion SPECT/CT
    Rajaraman, V.
    Ponnusamy, M.
    Halanaik, D.
    Pandit, N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S735 - S735
  • [33] Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations
    Moore, B.
    Brady, S.
    Mirro, A.
    Kaufman, R.
    MEDICAL PHYSICS, 2014, 41 (06) : 424 - +
  • [34] The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations
    Franck, Caro
    Vandevoorde, Charlot
    Goethals, Ingeborg
    Smeets, Peter
    Achten, Eric
    Verstraete, Koenraad
    Thierens, Hubert
    Bacher, Klaus
    EUROPEAN RADIOLOGY, 2016, 26 (08) : 2646 - 2655
  • [35] Establishing Local Dose Reference Levels for Low-dose CT Scans Associated with SPECT and PET Imaging Examinations - Experience at Sultan Qaboos University, Oman
    Bouchareb, Y.
    Lag, N.
    Al-Jabri, A.
    Makhmari, N.
    Al-Haji, A.
    Al-Dhuhli, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S106 - S107
  • [36] Establishing Local Diagnostic Reference Levels in IR Procedures with Dose Management Software
    Heilmaier, Christina
    Zuber, Niklaus
    Berthold, Christian
    Kara, Levent
    Weishaupt, Dominik
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (03) : 429 - 441
  • [37] Local diagnostic reference level based on size-specific dose estimates: case of chest-abdomen-pelvis CT examination in a Moroccan hospital
    Ouaggou, Ibrahim Ait
    Bakari, Dikra
    Zerfaoui, Mustapha
    Rrhioua, Abdeslem
    Oulhouq, Yassine
    Benmessaoud, Mounir
    Ouhadda, Hassan
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2024,
  • [38] Size-specific Dose Estimation for CT: How Should It Be Used and What Does It Mean?
    Brink, James A.
    Morin, Richard L.
    RADIOLOGY, 2012, 265 (03) : 666 - 668
  • [39] Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction
    Gabusi, M.
    Riccardi, L.
    Aliberti, C.
    Vio, S.
    Paiusco, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 393 - 397
  • [40] Institutional computed tomography diagnostic reference levels based on water-equivalent diameter and size-specific dose estimates
    Boos, Johannes
    Thomas, Christoph
    Appel, Elisabeth
    Klosterkemper, Yan
    Schleich, Christoph
    Aissa, Joel
    Bethge, Oliver Th
    Antoch, Gerald
    Kroepil, Patric
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 536 - 548