Four-dimensional digital subtraction angiography to assess cerebral arteriovenous malformations

被引:2
|
作者
Xiang, Weichu [1 ]
Yan, Linhai [2 ]
Zhao, Yueyuan [1 ]
Yang, Ming [1 ]
Bai, Sanli [1 ]
Ma, Lianting [1 ]
Pan, Li [1 ]
机构
[1] Gen Hosp Cent Theater Command, Dept Neurosurg, 627 Wuluo Rd, Wuhan 430074, Peoples R China
[2] Guangzhou Med Univ, Dept Neurosurg, Affiliated Hosp 2, Guangzhou, Peoples R China
关键词
4D DSA; 4D DSA prototype; agreement analysis; cerebral arteriovenous malformation; 3D ROTATIONAL ANGIOGRAPHY; 4D DSA; DISPLAY; 2D;
D O I
10.1111/jon.13065
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose The performance of a novel prototype four-dimensional (4D) digital subtraction angiography (DSA) for cerebral arteriovenous malformation (AVM) diagnosis was evaluated and compared with that of two-dimensional (2D) and three-dimensional (3D) DSA. Methods In this retrospective study, 37 consecutive cerebral AVM patients were included. The standard diagnostic results were concluded from the 2D and 3D DSA. Two 4D DSA volumes were reconstructed for each patient by a commercial and a prototype software, then evaluated by two independent experienced neurosurgeons, who were blinded to the diagnosis and treatment process. The evaluation results were compared with the diagnostic results on Spetzler-Martin (SM) Grading Scale, number of feeding arteries, number of draining veins, and intranidal aneurysms. Results Complete agreement was achieved between 4D DSA and 2D and 3D DSA in SM Grading Scale and intracranial aneurysm identification (agreement coefficient: 1) for both reviewers. The agreement coefficients were .888 and .917 for both reviewers in feeding artery number determination using 4D DSA product and 4D DSA prototype, respectively. The agreement coefficients in draining vein number determination were all larger than .94 for both reviewers using both 4D DSA volumes. Conclusions The performance of this prototype 4D DSA in cerebral AVMs diagnosis was largely equivalent to that of 2D and 3D DSA combination. Four-dimensional DSA can be regarded as a very good complement for 2D DSA in cerebral AVM diagnosis.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 50 条
  • [41] Segmentation of Arteriovenous Malformations Nidus and Vessel in Digital Subtraction Angiography Images Based on an Iterative Thresholding Method
    Lian, Yuxi
    Wang, Yuanyuan
    Yu, Jinhua
    Guo, Yi
    Chen, Liang
    2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 111 - 115
  • [42] Evaluation of Intracranial Arteriovenous Malformations With Four-Dimensional Arterial-Spin Labeling Based 3-T Magnetic Resonance Angiography
    Iryo, Yasuhiko
    Hirai, Toshinori
    Nakamura, Masanobu
    Kawano, Takayuki
    Kaku, Yasuyuki
    Ohmori, Yuki
    Kai, Yutaka
    Azuma, Minako
    Nishimura, Shinichiro
    Shigematsu, Yoshinori
    Kitajima, Mika
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (02) : 290 - 296
  • [43] The impact of digital subtraction angiography on arteriovenous fistula revision
    Foerster, R.
    Scholz, J.
    GEFASSCHIRURGIE, 2011, 16 (04): : 275 - 279
  • [44] SUBTRACTION SPIRAL CT ANGIOGRAPHY IN RADIOSURGERY OF INTRACRANIAL ARTERIOVENOUS-MALFORMATIONS
    HEIMBERGER, K
    KITZ, K
    GOERZER, H
    SCHINDLER, E
    TRATTNIG, S
    RADIOLOGY, 1995, 197 : 275 - 275
  • [45] Four-dimensional CT angiography (4D-CTA) in the evaluation of juvenile nasopharyngeal angiofibromas: comparison with digital subtraction angiography (DSA) and surgical findings
    Xiao, Zebin
    Zheng, Yingyan
    Li, Jian
    Chen, Dehua
    Liu, Fang
    Cao, Dairong
    DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (08)
  • [46] Volume measurement of cerebral arteriovenous malformations from angiography
    M. Söderman
    B. Karlsson
    L. Launnay
    B. Thuresson
    K. Ericson
    Neuroradiology, 2000, 42 : 697 - 702
  • [47] ARTERIOVENOUS MALFORMATION OF THE GREAT CEREBRAL VEIN (OF GALEN) IN A NEWBORN - DIAGNOSIS BY ULTRASOUND AND DIGITAL SUBTRACTION ANGIOGRAPHY
    LANGER, R
    KAUFMANN, HJ
    EUROPEAN JOURNAL OF PEDIATRICS, 1987, 146 (01) : 87 - 89
  • [48] Volume measurement of cerebral arteriovenous malformations from angiography
    Söderman, M
    Karlsson, B
    Launnay, L
    Thuresson, B
    Ericson, K
    NEURORADIOLOGY, 2000, 42 (09) : 697 - 702
  • [49] MRI AND MR ANGIOGRAPHY OF CEREBRAL ARTERIOVENOUS-MALFORMATIONS
    LAYER, G
    SEMMLER, W
    SCHAD, LR
    WOWRA, B
    VANKAICK, G
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (04): : 438 - 444
  • [50] Diagnosis of cerebral aneurysm using 3-dimensional digital subtraction angiography
    Nanba, R
    Houkin, K
    Kuroda, S
    Iwasaki, Y
    Ushikoshi, S
    Asano, T