X-Site Substituted 2D Cs2Pb(SCN)2Br2 Perovskites for X-Ray Detection

被引:9
|
作者
Liu, Dan [1 ]
Di, Haipeng [1 ]
Ren, Jiwei [1 ]
Jiang, Wei [1 ]
Li, Haibin [1 ]
Zhao, Chen [1 ]
Xin, Deyu [2 ]
Xing, Zhenning [1 ]
Zheng, Xiaojia [2 ]
Zhao, Yiying [1 ]
机构
[1] China Acad Engn Phys, Inst Mat, Jiangyou 621908, Peoples R China
[2] China Acad Engn Phys, Inst Chem Mat, Mianyang 621900, Peoples R China
基金
中国国家自然科学基金;
关键词
Cs2Pb(SCN)(2)Br-2 wafer; high stability; low-detection limit; X-ray detection; X-site substituted perovskite; METAL HALIDE PEROVSKITES; SINGLE-CRYSTALS; GROWTH;
D O I
10.1002/smll.202304201
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
2D Ruddlesden-Popper (RP) perovskites have been intensively investigated due to their superior stability and outstanding optoelectrical properties. However, investigations on 2D RP perovskites are mainly focused on A-site substituted perovskites and few reports are on X-site substituted perovskites especially in X-ray detection field. Here, X-site substituted 2D RP perovskite Cs2Pb(SCN)(2)Br-2 polycrystalline wafers are prepared and systematically studied for X-ray detection. The obtained wafers show a large resistivity of 2.0 x 10(10) Omega cm, a high ion activation energy of 0.75 eV, a small current drift of 2.39 x 10(-6) nA cm(-1) s(-1) V-1, and charge carrier mobility-lifetime product under X-ray as high as 1.29 x 10(-4) cm(2) V-1. These merits enable Cs2Pb(SCN)(2)Br-2 wafer detectors with a sensitivity of 216.3 mu C Gy(air)(-1) cm(-2), a limit of detection of 42.4 nGy(air) s(-1), and good imaging ability with high spatial resolution of 1.08 lp mm(-1). In addition, Cs2Pb(SCN)(2)Br-2 wafer detectors demonstrate excellent operational stability under high working field up to 2100 V cm(-1) after continuous X-ray irradiation with a total dose of 45.2 Gy(air). The promising features such as short octahedral spacing and weak ion migration will open up a new perspective and opportunity for SCN-based 2D perovskites in X-ray detection.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] 3D interventional imaging with 2D x-ray detectors
    Desbat, L
    Champleboux, G
    Fleute, M
    Komarek, P
    Mennessier, C
    Monteil, B
    Rodet, T
    Bessou, P
    Coulomb, M
    Ferretti, G
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 973 - 980
  • [42] Simple techniques for measuring the performance of 2D X-ray detectors
    Adam, Martin
    He, Tim
    Durst, Roger
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2011, 67 : C809 - C809
  • [43] The 2D X-ray detector development program for the European XFEL
    Schwarz, Andreas S.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C162 - C162
  • [44] 2D material offers alternative to lead X-ray shielding
    Sealy, Cordelia
    MATERIALS TODAY, 2022, 59 : 5 - 6
  • [45] Microsecond time-resolved 2D X-ray imaging
    Sarvestani, A
    Sauer, N
    Strietzel, C
    Besch, HJ
    Orthen, A
    Pavel, N
    Walenta, AH
    Menk, RH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 465 (2-3): : 354 - 364
  • [46] Analysis of hard X-ray focusing by 2D diamond CRL
    Chubar, Oleg
    Wiegart, Lutz
    Antipov, Sergey
    Celestre, Rafael
    Coles, Rebecca
    Fluerasu, Andrei
    Rakitin, Maksim
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS V, 2020, 11493
  • [47] 2D material offers alternative to lead X-ray shielding
    Sealy, Cordelia
    MATERIALS TODAY, 2022, 59 : 5 - 6
  • [48] Two-Dimensional Cs2Pb(SCN)2Br2-Based Photomemory Devices Showing a Photoinduced Recovery Behavior and an Unusual Fully Optically Driven Memory Behavior
    Liao, Ming-Yun
    Chiang, Yun-Chi
    Chen, Chiung-Han
    Chen, Wen-Chang
    Chueh, Chu-Chen
    ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (32) : 36398 - 36408
  • [49] TlSr2Br5: New intrinsic scintillator for X-ray and γ-ray detection
    Rooh, Gul
    Khan, Arshad
    Kim, H. J.
    Park, H.
    Kim, Sunghwan
    OPTICAL MATERIALS, 2017, 73 : 523 - 526
  • [50] X-ray studies on polymers and composites: the combination of 2D WAXS, SAXS and X-ray imaging techniques
    Neels, Antonia
    Kaufmann, Rolf
    Bauer, Monika
    Vacche, Sara Dalle
    Leterrier, Yves
    Dommann, Alex
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2016, 72 : S139 - S139