X-Site Substituted 2D Cs2Pb(SCN)2Br2 Perovskites for X-Ray Detection

被引:9
|
作者
Liu, Dan [1 ]
Di, Haipeng [1 ]
Ren, Jiwei [1 ]
Jiang, Wei [1 ]
Li, Haibin [1 ]
Zhao, Chen [1 ]
Xin, Deyu [2 ]
Xing, Zhenning [1 ]
Zheng, Xiaojia [2 ]
Zhao, Yiying [1 ]
机构
[1] China Acad Engn Phys, Inst Mat, Jiangyou 621908, Peoples R China
[2] China Acad Engn Phys, Inst Chem Mat, Mianyang 621900, Peoples R China
基金
中国国家自然科学基金;
关键词
Cs2Pb(SCN)(2)Br-2 wafer; high stability; low-detection limit; X-ray detection; X-site substituted perovskite; METAL HALIDE PEROVSKITES; SINGLE-CRYSTALS; GROWTH;
D O I
10.1002/smll.202304201
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
2D Ruddlesden-Popper (RP) perovskites have been intensively investigated due to their superior stability and outstanding optoelectrical properties. However, investigations on 2D RP perovskites are mainly focused on A-site substituted perovskites and few reports are on X-site substituted perovskites especially in X-ray detection field. Here, X-site substituted 2D RP perovskite Cs2Pb(SCN)(2)Br-2 polycrystalline wafers are prepared and systematically studied for X-ray detection. The obtained wafers show a large resistivity of 2.0 x 10(10) Omega cm, a high ion activation energy of 0.75 eV, a small current drift of 2.39 x 10(-6) nA cm(-1) s(-1) V-1, and charge carrier mobility-lifetime product under X-ray as high as 1.29 x 10(-4) cm(2) V-1. These merits enable Cs2Pb(SCN)(2)Br-2 wafer detectors with a sensitivity of 216.3 mu C Gy(air)(-1) cm(-2), a limit of detection of 42.4 nGy(air) s(-1), and good imaging ability with high spatial resolution of 1.08 lp mm(-1). In addition, Cs2Pb(SCN)(2)Br-2 wafer detectors demonstrate excellent operational stability under high working field up to 2100 V cm(-1) after continuous X-ray irradiation with a total dose of 45.2 Gy(air). The promising features such as short octahedral spacing and weak ion migration will open up a new perspective and opportunity for SCN-based 2D perovskites in X-ray detection.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] SYNTHESIS OF A MIXED-VALENCE AUI/AUIII COMPLEX, [AU(CH2)2PPH2]2BR2, AND ITS CHARACTERIZATION BY X-RAY CRYSTALLOGRAPHY AND X-RAY PHOTOELECTRON-SPECTROSCOPY
    RAPTIS, RG
    PORTER, LC
    EMRICH, RJ
    MURRAY, HH
    FACKLER, JP
    INORGANIC CHEMISTRY, 1990, 29 (22) : 4408 - 4412
  • [22] Robust and Fast Contrast Inflow Detection for 2D X-ray Fluoroscopy
    Chen, Terrence
    Funka-Lea, Gareth
    Comaniciu, Dorin
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 243 - 250
  • [23] Crystallized 2D perovskite for X-ray and visible light detection applications
    Nie, Lebin
    Sun, Jiayun
    Li, Gang
    Wang, Kai
    Choy, Wallace C. H.
    ORGANIC, HYBRID, AND PEROVSKITE PHOTOVOLTAICS XXIII, 2022, 12209
  • [24] X-ray strain analysis in thin films enhanced by 2D detection
    Geandier, G.
    Faurie, D.
    Renault, P. -O.
    Le Bourlot, C.
    Djemia, P.
    Castelnau, O.
    Cherif, S. M.
    Le Bourhis, E.
    Goudeau, Ph
    ICEM 14: 14TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, VOL 6, 2010, 6
  • [25] Medical quantum X-ray imaging with 2D detectors
    Giersch, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 551 (01): : 125 - 138
  • [26] Measurement of the x-ray diffraction phase in a 2D crystal
    Baltes, H
    Yacoby, Y
    Pindak, R
    Clarke, R
    Pfeiffer, L
    Berman, L
    PHYSICAL REVIEW LETTERS, 1997, 79 (07) : 1285 - 1288
  • [27] Finding Similar 2D X-Ray Coronary Angiograms
    Syeda-Mahmood, Tanveer
    Wang, Fei
    Kumar, R.
    Beymer, D.
    Zhang, Y.
    Lundstrom, Robert
    McNulty, Edward
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT III, 2012, 7512 : 501 - 508
  • [28] X-ray Interior Tensor Tomography with 2D Gratings
    Chen, Mianyi
    Yang, Qingsong
    Cong, Wenxiang
    Wei, Biao
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [29] A fully automatic stitching of 2D X-ray images
    Mateika, D.
    Martavicius, R.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2007, (08) : 3 - 8
  • [30] VISUALISATION OF DYNAMIC ADSORPTION BY 2D X-RAY RADIOGRAPHY AND 3D X-RAY μ-TOMOGRAPHY
    Almazan-Almazan, M. C.
    Leonard, A.
    Toye, D.
    Lodewyckx, P.
    Pirard, J. P.
    Lopez-Garzon, F. J.
    Blacher, S.
    CHARACTERISATION OF POROUS SOLIDS VIII, 2009, (318): : 233 - 239