Comparison of electrical impedance tomography and spirometry-based measures of airflow in healthy adult horses

被引:1
|
作者
Byrne, David P. [1 ]
Keeshan, Ben [2 ]
Hosgood, Giselle [1 ]
Adler, Andy [2 ]
Mosing, Martina [3 ]
机构
[1] Murdoch Univ, Sch Vet Med, Perth, WA, Australia
[2] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON, Canada
[3] Univ Vet Med, Dept Compan Anim & Horses, Anaesthesiol & Perioperat Intens Care, Vienna, Austria
关键词
asthma; equine; expiratory; inspiratory; peak flow; plethysmography; REGIONAL LUNG-FUNCTION; RESPIRATORY-FUNCTION; ANESTHETIZED HORSES; VENTILATION; OBSTRUCTION; ANESTHESIA; FREQUENCY; PRESSURE; HEAVES; MASK;
D O I
10.3389/fphys.2023.1164646
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Electrical impedance tomography (EIT) is a non-invasive diagnostic tool for evaluating lung function. The objective of this study was to compare respiratory flow variables calculated from thoracic EIT measurements with corresponding spirometry variables. Ten healthy research horses were sedated and instrumented with spirometry via facemask and a single-plane EIT electrode belt around the thorax. Horses were exposed to sequentially increasing volumes of apparatus dead space between 1,000 and 8,500 mL, in 5-7 steps, to induce carbon dioxide rebreathing, until clinical hyperpnea or a tidal volume of 150% baseline was reached. A 2-min stabilization period followed by 2 minutes of data collection occurred at each timepoint. Peak inspiratory and expiratory flow, inspiratory and expiratory time, and expiratory nadir flow, defined as the lowest expiratory flow between the deceleration of flow of the first passive phase of expiration and the acceleration of flow of the second active phase of expiration were evaluated with EIT and spirometry. Breathing pattern was assessed based on the total impedance curve. Bland-Altman analysis was used to evaluate the agreement where perfect agreement was indicated by a ratio of EIT:spirometry of 1.0. The mean ratio (bias; expressed as a percentage difference from perfect agreement) and the 95% confidence interval of the bias are reported. There was good agreement between EIT-derived and spirometry-derived peak inspiratory [-15% (-46-32)] and expiratory [10% (-32-20)] flows and inspiratory [-6% (-25-18)] and expiratory [5% (-9-20)] times. Agreement for nadir flows was poor [-22% (-87-369)]. Sedated horses intermittently exhibited Cheyne-Stokes variant respiration, and a breath pattern with incomplete expiration in between breaths (crown-like breaths). Electrical impedance tomography can quantify airflow changes over increasing tidal volumes and changing breathing pattern when compared with spirometry in standing sedated horses.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Lobe based image reconstruction in Electrical Impedance Tomography
    Schullcke, Benjamin
    Gong, Bo
    Krueger-Ziolek, Sabine
    Tawhai, Merryn
    Adler, Andy
    Mueller-Lisse, Ullrich
    Moeller, Knut
    MEDICAL PHYSICS, 2017, 44 (02) : 426 - 436
  • [32] Electrical impedance tomography based on improved MRNSD algorithm
    Fan W.
    Li J.
    Wang B.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2020, 46 (08): : 1564 - 1573
  • [33] Electrical Impedance Tomography Based on Direct Search Method
    蔡畅
    严壮志
    Journal of Shanghai University, 2005, (05) : 432 - 436
  • [34] Pattern recognition based imaging in electrical impedance tomography
    Mikhailova, O
    Dai, WW
    Chee, J
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 762 - 763
  • [35] Electrical Impedance Tomography based sensors for semiconductor manufacturing
    Krüger, MVP
    Poolla, K
    Spanos, CJ
    PROCEEDINGS OF THE 2002 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2002, 1-6 : 3678 - 3683
  • [36] Noise-based correction for electrical impedance tomography
    Mason, Kai
    Maurino-Alperovich, Florencia
    Holder, David
    Aristovich, Kirill
    PHYSIOLOGICAL MEASUREMENT, 2024, 45 (06)
  • [37] Electrical impedance tomography system based on active electrodes
    Gaggero, Pascal Olivier
    Adler, Andy
    Brunner, Josef
    Seitz, Peter
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (05) : 831 - 847
  • [38] Construction of the SmartEIT tomograph based on electrical impedance tomography
    Rymarczyk, Tomasz
    Bozek, Piotr
    Oleszek, Michal
    Niderla, Konrad
    Adamkiewicz, Przemyslaw
    PRZEGLAD ELEKTROTECHNICZNY, 2020, 96 (02): : 44 - 47
  • [39] Tidal volume monitoring with electrical impedance tomography. validation for healthy subjects
    Balleza, M.
    Fornos, J.
    Calaf, N.
    Feixas, T.
    Gonzalez, M.
    Anton, D.
    Riu, P. J.
    Casan, P.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 572 - +
  • [40] Comparison of Indicator-Based Electrical Impedance Tomography with Positron Emission Tomography for Measurements of Relative Lung Perfusion in Pigs
    Braune, A.
    Kircher, M.
    Bluth, T.
    Kiss, T.
    Bozsak, C.
    Huhle, R.
    Scharffenberg, M.
    Herzog, M.
    Roegner, J.
    Vivona, L.
    Millone, M.
    Doessel, O.
    Andreeff, M.
    Koch, T.
    Kotzerke, J.
    Stender, B.
    de Abreu, M. Gama
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197