Comparison of electrical impedance tomography and spirometry-based measures of airflow in healthy adult horses

被引:1
|
作者
Byrne, David P. [1 ]
Keeshan, Ben [2 ]
Hosgood, Giselle [1 ]
Adler, Andy [2 ]
Mosing, Martina [3 ]
机构
[1] Murdoch Univ, Sch Vet Med, Perth, WA, Australia
[2] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON, Canada
[3] Univ Vet Med, Dept Compan Anim & Horses, Anaesthesiol & Perioperat Intens Care, Vienna, Austria
关键词
asthma; equine; expiratory; inspiratory; peak flow; plethysmography; REGIONAL LUNG-FUNCTION; RESPIRATORY-FUNCTION; ANESTHETIZED HORSES; VENTILATION; OBSTRUCTION; ANESTHESIA; FREQUENCY; PRESSURE; HEAVES; MASK;
D O I
10.3389/fphys.2023.1164646
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Electrical impedance tomography (EIT) is a non-invasive diagnostic tool for evaluating lung function. The objective of this study was to compare respiratory flow variables calculated from thoracic EIT measurements with corresponding spirometry variables. Ten healthy research horses were sedated and instrumented with spirometry via facemask and a single-plane EIT electrode belt around the thorax. Horses were exposed to sequentially increasing volumes of apparatus dead space between 1,000 and 8,500 mL, in 5-7 steps, to induce carbon dioxide rebreathing, until clinical hyperpnea or a tidal volume of 150% baseline was reached. A 2-min stabilization period followed by 2 minutes of data collection occurred at each timepoint. Peak inspiratory and expiratory flow, inspiratory and expiratory time, and expiratory nadir flow, defined as the lowest expiratory flow between the deceleration of flow of the first passive phase of expiration and the acceleration of flow of the second active phase of expiration were evaluated with EIT and spirometry. Breathing pattern was assessed based on the total impedance curve. Bland-Altman analysis was used to evaluate the agreement where perfect agreement was indicated by a ratio of EIT:spirometry of 1.0. The mean ratio (bias; expressed as a percentage difference from perfect agreement) and the 95% confidence interval of the bias are reported. There was good agreement between EIT-derived and spirometry-derived peak inspiratory [-15% (-46-32)] and expiratory [10% (-32-20)] flows and inspiratory [-6% (-25-18)] and expiratory [5% (-9-20)] times. Agreement for nadir flows was poor [-22% (-87-369)]. Sedated horses intermittently exhibited Cheyne-Stokes variant respiration, and a breath pattern with incomplete expiration in between breaths (crown-like breaths). Electrical impedance tomography can quantify airflow changes over increasing tidal volumes and changing breathing pattern when compared with spirometry in standing sedated horses.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Simple Electrical Impedance Tomography Measures for the Assessment of Ventilation Distribution Reply
    Brochard, Laurent
    Yoshida, Takeshi
    Amato, Marcelo
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201 (03) : 388 - 388
  • [22] Evaluation of electrical impedance tomography for determination of urinary bladder volume: comparison with standard ultrasound methods in healthy volunteers
    Dorothea Leonhäuser
    Carlos Castelar
    Thomas Schlebusch
    Martin Rohm
    Rüdiger Rupp
    Steffen Leonhardt
    Marian Walter
    Joachim O. Grosse
    BioMedical Engineering OnLine, 17
  • [23] Evaluation of electrical impedance tomography for determination of urinary bladder volume: comparison with standard ultrasound methods in healthy volunteers
    Leonhaeuser, Dorothea
    Castelar, Carlos
    Schlebusch, Thomas
    Rohm, Martin
    Rupp, Ruediger
    Leonhardt, Steffen
    Walter, Marian
    Grosse, Joachim O.
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [24] A comparison framework for temporal image reconstructions in electrical impedance tomography
    Gagnon, Herve
    Grychtol, Bartlomiej
    Adler, Andy
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (06) : 1093 - 1107
  • [25] A comparison between compressed sensing algorithms in Electrical Impedance Tomography
    Tehrani, Joubin Nasehi
    Jin, Craig
    McEwan, Alistair
    van Schaik, Andre
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3109 - 3112
  • [26] Methodology of electrical impedance tomography-derived measures of regional lung ventilation
    Frerichs, Inez
    Becher, Tobias
    Weiler, Norbert
    CRITICAL CARE, 2014, 18 (06):
  • [27] Electrical characteristics of real head model based on electrical impedance tomography
    Xu, GZ
    Yang, QX
    Yang, S
    Liu, FG
    Yan, WL
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2004, 14 (02) : 1617 - 1620
  • [28] Methodology of electrical impedance tomography-derived measures of regional lung ventilation
    Inéz Frerichs
    Tobias Becher
    Norbert Weiler
    Critical Care, 18
  • [29] Development of a Microcontroller based Electrical Impedance Tomography System
    Singh, Gurmeet
    Anand, Sneh
    Lall, Brejesh
    Srivastava, Anurag
    Singh, Vaneet
    2015 IEEE LONG ISLAND SYSTEMS, APPLICATIONS AND TECHNOLOGY CONFERENCE (LISAT), 2015,
  • [30] Electrical Impedance Tomography Algorithm Based on Fuzzy Operator
    Yue S.
    Rong X.
    Ma H.
    Lu J.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2021, 54 (02): : 179 - 185