Real-time tumor-tracking radiotherapy with SyncTraX for primary liver tumors requiring isocenter shift

被引:0
|
作者
Uchinami, Yusuke [1 ,2 ]
Miyamoto, Naoki [3 ,4 ]
Abo, Daisuke [5 ]
Morita, Ryo [5 ]
Ogawa, Koji [6 ]
Kakisaka, Tatsuhiko [7 ]
Suzuki, Ryusuke [3 ]
Miyazaki, Tomohiko [8 ]
Taguchi, Hiroshi [8 ]
Katoh, Norio [1 ,2 ]
Aoyama, Hidefumi [1 ,2 ]
机构
[1] Hokkaido Univ, Dept Radiat Oncol, Fac Med, North 15 West 7,Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Grad Sch Med, North 15 West 7,Kita Ku, Sapporo, Hokkaido 0608638, Japan
[3] Hokkaido Univ Hosp, Dept Med Phys, North 14 West 5,Kita Ku, Sapporo, Hokkaido 0608648, Japan
[4] Hokkaido Univ, Div Appl Quantum Sci & Engn, Fac Engn, North 13 West 8,Kita Ku, Sapporo, Hokkaido 0608628, Japan
[5] Hokkaido Univ Hosp, Dept Diagnost & Intervent Radiol, North 14 West 5,Kita Ku, Sapporo, Hokkaido 0608648, Japan
[6] Hokkaido Univ, Dept Gastroenterol & Hepatol, Fac Med, North 15 West 7,Kita Ku, Sapporo, Hokkaido 0608638, Japan
[7] Hokkaido Univ, Dept Gastroenterol Surg, Fac Med, North 15 West 7,Kita Ku, Sapporo, Hokkaido 0608638, Japan
[8] Hokkaido Univ Hosp, Dept Radiat Oncol, North 14 West 5,Kita Ku, Sapporo, Hokkaido 0608648, Japan
基金
日本学术振兴会;
关键词
SyncTraX; SyncTraX FX4; primary liver tumors; SBRT; real-time tumor-tracking radiotherapy; STEREOTACTIC BODY RADIATION; FIDUCIAL MARKERS; HEPATOCELLULAR-CARCINOMA; THERAPY; SYSTEM; SBRT;
D O I
10.1093/jrr/rrad088
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The SyncTraX series enables real-time tumor-tracking radiotherapy through the real-time recognition of a fiducial marker using fluoroscopic images. In this system, the isocenter should be located within approximately 5-7.5 cm from the marker, depending on the version, owing to the limited field of view. If the marker is placed away from the tumor, the isocenter should be shifted toward the marker. This study aimed to investigate stereotactic body radiotherapy (SBRT) outcomes of primary liver tumors treated with SyncTraX in cases where the isocenter was shifted marginally or outside the planning target volume (PTV). Twelve patients with 13 liver tumors were included in the analysis. Their isocenter was shifted toward the marker and was placed marginally or outside the PTV. The prescribed doses were generally 40 Gy in four fractions or 48 Gy in eight fractions. The overall survival (OS) and local control (LC) rates were calculated using the Kaplan-Meier method. All patients completed the scheduled SBRT. The median distance between the fiducial marker and PTV centroid was 56.0 (interquartile range [IQR]: 52.7-66.7) mm. By shifting the isocenter toward the marker, the median distance between the marker and isocenter decreased to 34.0 (IQR: 33.4-39.7) mm. With a median follow-up period of 25.3 (range: 6.9-70.0) months, the 2-year OS and LC rates were 100.0% (95% confidence interval: 100-100). An isocenter shift makes SBRT with SyncTraX feasible in cases where the fiducial marker is distant from the tumor.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 50 条
  • [41] Motion Adaptive Image Filter for Low Dose X-Ray Fluoroscopy in the Real-Time Tumor-Tracking Radiotherapy System
    Miyamoto, N.
    Ishikawa, M.
    Sutherland, K.
    Suzuki, R.
    Matsuura, T.
    Takao, S.
    Toramatsu, C.
    Nihongi, H.
    Shimizu, S.
    Onimaru, R.
    Umegaki, K.
    Shirato, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3661 - 3662
  • [42] A novel dynamic robotic moving phantom system for patient-specific quality assurance in real-time tumor-tracking radiotherapy
    Shiinoki, Takehiro
    Fujii, Fumitake
    Fujimoto, Koya
    Yuasa, Yuki
    Sera, Tatsuhiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07): : 16 - 28
  • [43] Clinical Result of Dynamic Tumor-Tracking Stereotactic Body Radiation Therapy With Real-Time Monitoring for Liver Tumors Using a Gimbal Mounted Linear Accelerator
    Iizuka, Y.
    Matsuo, Y.
    Takayama, K.
    Ueki, N.
    Mitsuyoshi, T.
    Ueki, K.
    Tanabe, H.
    Nakamura, M.
    Mizowaki, T.
    Kokubo, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E148 - E149
  • [44] Clinical results of dynamic tumor-tracking stereotactic body radiotherapy with real-time monitoring for liver tumors using a gimbal-mounted linac: A multi-institutional phase II study
    Iizuka, Yusuke
    Hiraoka, Masahiro
    Kokubo, Masaki
    Sakamoto, Takashi
    Karasawa, Katsuyuki
    Murofushi, Keiko
    Nakamura, Mitsuhiro
    Matsuo, Yukinori
    Morita, Satoshi
    Inokuchi, Haruo
    Mizowaki, Takashi
    JOURNAL OF CLINICAL ONCOLOGY, 2022, 40 (04)
  • [45] Reproducibility of Tumor Motion Probability Distribution Function in Stereotactic Body Radiation Therapy of Lung Using Real-Time Tumor-Tracking Radiotherapy System
    Shiinoki, T.
    Kawamura, S.
    Hanazawa, H.
    Park, S.
    Uehara, T.
    Yuasa, Y.
    Koike, M.
    Takahashi, T.
    Shibuya, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3307 - 3307
  • [46] Integration of fluoroscopic real-time tumor-tracking system and tomographic scanner on the rail in the treatment room
    Ebe, K
    Shirato, H
    Hiyama, A
    Kanzaki, R
    Tsukamoto, K
    Ariga, M
    Karino, Y
    Mukae, H
    Matsumoto, T
    Matsunaga, N
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S604 - S604
  • [47] Safe Distance Limit between the Target and Intestinal Tract in Real-Time Tracking Radiotherapy for Liver Tumors
    Kawaguchi, G.
    Tanabe, S.
    Utsunomiya, S.
    Umetsu, O.
    Sasage, T.
    Kuwabara, R.
    Kuribayashi, T.
    Kamimura, T.
    Satou, Y.
    Takatou, H.
    Aoyama, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E765 - E765
  • [48] Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions
    Kitamura, K
    Shirato, H
    Seppenwoolde, Y
    Onimaru, R
    Oda, M
    Fujita, K
    Shimizu, S
    Shinohara, N
    Harabayashi, T
    Miyasaka, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05): : 1117 - 1123
  • [49] Bladder-preserving therapy using a real-time tumor-tracking radiotherapy system for muscle-invasive bladder cancer.
    Miyata, Haruka
    Osawa, Takahiro
    Frumido, Jun
    Kikuchi, Hiroshi
    Matsumoto, Ryuji
    Abe, Takashige
    Maruyama, Satoru
    Nishioka, Kentaro
    Shimizu, Shinichi
    Hashimoto, Takayuki
    Shirato, Hiroki
    Shinohara, Nobuo
    JOURNAL OF CLINICAL ONCOLOGY, 2019, 37 (07)
  • [50] Improving the accuracy of motion quantification using area detector computed tomography for real-time tumor-tracking irradiation in stereotactic ablative radiotherapy
    Suzuki, Kentaro
    Usui, Keisuke
    Sasai, Keisuke
    MEDICAL DOSIMETRY, 2022, 47 (02) : 166 - 172