Real-time tumor-tracking radiotherapy with SyncTraX for primary liver tumors requiring isocenter shift

被引:0
|
作者
Uchinami, Yusuke [1 ,2 ]
Miyamoto, Naoki [3 ,4 ]
Abo, Daisuke [5 ]
Morita, Ryo [5 ]
Ogawa, Koji [6 ]
Kakisaka, Tatsuhiko [7 ]
Suzuki, Ryusuke [3 ]
Miyazaki, Tomohiko [8 ]
Taguchi, Hiroshi [8 ]
Katoh, Norio [1 ,2 ]
Aoyama, Hidefumi [1 ,2 ]
机构
[1] Hokkaido Univ, Dept Radiat Oncol, Fac Med, North 15 West 7,Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Grad Sch Med, North 15 West 7,Kita Ku, Sapporo, Hokkaido 0608638, Japan
[3] Hokkaido Univ Hosp, Dept Med Phys, North 14 West 5,Kita Ku, Sapporo, Hokkaido 0608648, Japan
[4] Hokkaido Univ, Div Appl Quantum Sci & Engn, Fac Engn, North 13 West 8,Kita Ku, Sapporo, Hokkaido 0608628, Japan
[5] Hokkaido Univ Hosp, Dept Diagnost & Intervent Radiol, North 14 West 5,Kita Ku, Sapporo, Hokkaido 0608648, Japan
[6] Hokkaido Univ, Dept Gastroenterol & Hepatol, Fac Med, North 15 West 7,Kita Ku, Sapporo, Hokkaido 0608638, Japan
[7] Hokkaido Univ, Dept Gastroenterol Surg, Fac Med, North 15 West 7,Kita Ku, Sapporo, Hokkaido 0608638, Japan
[8] Hokkaido Univ Hosp, Dept Radiat Oncol, North 14 West 5,Kita Ku, Sapporo, Hokkaido 0608648, Japan
基金
日本学术振兴会;
关键词
SyncTraX; SyncTraX FX4; primary liver tumors; SBRT; real-time tumor-tracking radiotherapy; STEREOTACTIC BODY RADIATION; FIDUCIAL MARKERS; HEPATOCELLULAR-CARCINOMA; THERAPY; SYSTEM; SBRT;
D O I
10.1093/jrr/rrad088
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The SyncTraX series enables real-time tumor-tracking radiotherapy through the real-time recognition of a fiducial marker using fluoroscopic images. In this system, the isocenter should be located within approximately 5-7.5 cm from the marker, depending on the version, owing to the limited field of view. If the marker is placed away from the tumor, the isocenter should be shifted toward the marker. This study aimed to investigate stereotactic body radiotherapy (SBRT) outcomes of primary liver tumors treated with SyncTraX in cases where the isocenter was shifted marginally or outside the planning target volume (PTV). Twelve patients with 13 liver tumors were included in the analysis. Their isocenter was shifted toward the marker and was placed marginally or outside the PTV. The prescribed doses were generally 40 Gy in four fractions or 48 Gy in eight fractions. The overall survival (OS) and local control (LC) rates were calculated using the Kaplan-Meier method. All patients completed the scheduled SBRT. The median distance between the fiducial marker and PTV centroid was 56.0 (interquartile range [IQR]: 52.7-66.7) mm. By shifting the isocenter toward the marker, the median distance between the marker and isocenter decreased to 34.0 (IQR: 33.4-39.7) mm. With a median follow-up period of 25.3 (range: 6.9-70.0) months, the 2-year OS and LC rates were 100.0% (95% confidence interval: 100-100). An isocenter shift makes SBRT with SyncTraX feasible in cases where the fiducial marker is distant from the tumor.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 50 条
  • [11] Real-Time Tumor-Tracking Radiotherapy and General Stereotactic Body Radiotherapy for Adrenal Metastasis in Patients With Oligometastasis
    Katoh, Norio
    Onishi, Hiroshi
    Uchinami, Yusuke
    Inoue, Tetsuya
    Kuriyama, Kengo
    Nishioka, Kentaro
    Shimizu, Shinichi
    Komiyama, Takafumi
    Miyamoto, Naoki
    Shirato, Hiroki
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2018, 17
  • [12] Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy
    Shirato, Hiroki
    Shimizu, Shinichi
    Kitamura, Kei
    Onimaru, Rikiya
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2007, 12 (01) : 8 - 16
  • [13] Improvement of tracking accuracy and stability by recursive image processing in real-time tumor-tracking radiotherapy system
    Miyamoto, Naoki
    Sutherland, Kenneth
    Suzuki, Ryusuke
    Matsuura, Taeko
    Toramatsu, Chie
    Takao, Seishin
    Nihongi, Hideaki
    Kinoshita, Rumiko
    Shimizu, Shinichi
    Onimaru, Rikiya
    Umegaki, Kikuo
    Shirato, Hiroki
    Ishikawa, Masayori
    MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [14] Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy
    Hiroki Shirato
    Shinichi Shimizu
    Kei Kitamura
    Rikiya Onimaru
    International Journal of Clinical Oncology, 2007, 12 : 8 - 16
  • [15] Fluctuation in speed and amplitude of lung tumor motion detected by real-time tumor-tracking radiotherapy system
    Onodeara, S
    Fujino, M
    Fujita, K
    Onimaru, R
    Aoyama, H
    Sharp, G
    Shirato, H
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 : S86 - S87
  • [16] Three-Dimensional Isocenter Verification for Real-Time Tumor-Tracking Radiotherapy System Using a Reusable PVA-I Radiochromic Gel Dosimeter
    Ono, K.
    Sera, T.
    Shiinoki, T.
    Hayashi, S.
    Fujino, K.
    Akagi, Y.
    Hirokawa, Y.
    MEDICAL PHYSICS, 2020, 47 (06) : E865 - E865
  • [17] Improvement of Tracking Accuracy and Stability with Utilizing a Color Image Intensifier in Real-time Tumor-tracking Radiotherapy System
    Miyamoto, N.
    Ishikawa, M.
    Bengua, G.
    Sutherland, K.
    Suzuki, R.
    Shirato, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S678 - S678
  • [18] Outcome and Pneumonitis in Lung Cancer Patients Treated with Stereotactic Real-time Tumor-tracking Radiotherapy
    Torres, M.
    Onodera, Y.
    Bengua, G.
    Inoue, T.
    Borst, G. R.
    Shirato, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S457 - S458
  • [19] Real-time and precise monitoring of the breast motion during irradiation using real-time tumor-tracking radiotherapy (RTRT) system
    Kinoshita, R.
    Shimizu, S.
    Katoh, N.
    Onimaru, R.
    Shirato, H.
    Miyasaka, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S608 - S608
  • [20] Real-time Tumor-tracking Radiation Therapy for Lymphoma of the Stomach
    Katoh, N.
    Suzuki, R.
    Shimizu, S.
    Inoue, T.
    Yasuda, K.
    Onimaru, R.
    Kimura, R.
    Kato, M.
    Ishikawa, M.
    Shirato, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S722 - S722