关键词
sewage source; heat pump; building heating and cooling; special sewage heat exchanger; energy saving; WATER; PERFORMANCE;
D O I
10.3390/buildings13051342
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Heat pump technology can extract low-level heat energy from urban sewage to heat or cool buildings, which can alleviate the two major problems of energy shortage and environmental pollution to a certain extent. This paper introduces the principle of wastewater source heat pump technology and summarizes the current common system forms and their key core technologies. The proposed special heat transfer technology for sewage can effectively solve the problem of blockage and corrosion in the process of sewage heat transfer. Taking the system of an office building in Qingdao as an example, the system design parameter is introduced in detail. The operation monitoring of the heating and air conditioning seasons of this project was completed through a data collection system, and various performance parameters of the system were studied and analyzed. The data was obtained using measured data from one year of system operation. The testing results show that the sewage temperature of the heat pump system in winter is approx. 13.5 degrees C, the hot water supply temperature is approx. 50 degrees C, the average COP of the unit is 3.95, and the average COP of the system is 2.96. The calculation results show that the heating energy consumption of the heat pump unit is only 50.81% of that of a traditional heating mode coal-fired boiler and 57.57% of that of an air source heat pump system. In summer, the sewage temperature is approx. 22 degrees C, the cold-water supply temperature is approx. 5.5 degrees C, the average COP of the unit is 4.45, and the average COP of the system is 3.25. The cooling energy consumption of the heat pump system is 79.39% of the energy consumption of the traditional chiller and 61.56% of the cooling energy consumption of the air source heat pump system. This shows that the sewage source heat pump system has a remarkable energy-saving effect.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Energy conservation and emissions reduction analysis of cooling water of power plant source heat in pump heating system
    Li Yang
    Liang Xiujuan
    2012 WORLD AUTOMATION CONGRESS (WAC), 2012,
  • [32] ECONOMICS ANALYSIS OF SEWAGE SOURCE HEAT PUMP SYSTEM
    Bing, Wei
    Bin, Zhang
    Lu, Jiang
    Wen, Luo
    ES2009: PROCEEDINGS OF THE ASME 3RD INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 1, 2009, : 547 - 552
  • [33] Heating and cooling experiments and feasibility study using heating and cooling load model for ground water heat pump system
    Nam, Yujin
    Ooka, Ryozo
    Journal of Environmental Engineering, 2009, 74 (638) : 473 - 479
  • [34] FOUR INNOVATIVE SOLAR COUPLED HEAT PUMP SOLUTIONS FOR BUILDING HEATING AND COOLING
    Cheze, David
    Cuneo, Alessandra
    Maccio, Carlo
    Porta, Matteo
    Dino, Giuseppe
    Frazzica, Andrea
    Gabaldon, Andrea
    PROCEEDINGS OF THE ISES EUROSUN 2020 CONFERENCE - 13TH INTERNATIONAL CONFERENCE ON SOLAR ENERGY FOR BUILDINGS AND INDUSTRY, 2020, : 419 - 430
  • [35] Application of ground-heat-source water thermal-storage with a heat-pump cooling and heating system
    Lim, K. B.
    Lee, S. H.
    Lee, C. H.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2010, 224 (E1) : 73 - 78
  • [36] Heating and cooling performance analysis of a ground source heat pump system in Southern Germany
    Luo, Jin
    Rohn, Joachim
    Bayer, Manfred
    Priess, Anna
    Wilkmann, Lucas
    Xiang, Wei
    GEOTHERMICS, 2015, 53 : 57 - 66
  • [37] Analysis of Sewage Heat Energy Application in Guiyang
    Zhao Qi-ming
    Zhu An
    Jiang Xiu-ya
    Long Jian
    PROGRESS IN MEASUREMENT AND TESTING, PTS 1 AND 2, 2010, 108-111 : 562 - +
  • [38] Application of heat pump water heating system with heat recovery in ammonia refrigeration system
    Huang, Tao
    Yuan, Dongli
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 670 - 673
  • [39] Exergy Analysis of a Ground Source Heat Pump System Under Cooling and Heating Conditions
    Zhao, Lei
    Yuan, Chen
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 799 - 806
  • [40] Energy evaluation of heating and cooling source use for surface water source heat pump system
    Long, Ji-Bo
    Li, Nian-Ping
    Ruan, Fang
    Huang, Si-Yi
    Huang, Ya-Bo
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2014, 41 (02): : 47 - 51