Application and Analysis of a Heat Pump System for Building Heating and Cooling Using Extracting Heat Energy from Untreated Sewage

被引:3
|
作者
Zhuang, Zhaoyi [1 ]
Zhao, Jin [1 ]
Mi, Fengfeng [2 ]
Zhang, Teng [3 ]
Hao, Yuguo [3 ]
Li, Shangyue [4 ]
机构
[1] Shandong Jianzhu Univ, Dept Thermal Energy Engn, Jinan 250101, Peoples R China
[2] Shandong Superego Ground Source Heat Pump Technol, Binzhou 256600, Peoples R China
[3] Shandong Zhong Ke Neng Artificial Environm Co Ltd, Heze 274032, Peoples R China
[4] Univ Glasgow, Sch Engn, Glasgow G12 8QQ, Scotland
基金
中国国家自然科学基金;
关键词
sewage source; heat pump; building heating and cooling; special sewage heat exchanger; energy saving; WATER; PERFORMANCE;
D O I
10.3390/buildings13051342
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Heat pump technology can extract low-level heat energy from urban sewage to heat or cool buildings, which can alleviate the two major problems of energy shortage and environmental pollution to a certain extent. This paper introduces the principle of wastewater source heat pump technology and summarizes the current common system forms and their key core technologies. The proposed special heat transfer technology for sewage can effectively solve the problem of blockage and corrosion in the process of sewage heat transfer. Taking the system of an office building in Qingdao as an example, the system design parameter is introduced in detail. The operation monitoring of the heating and air conditioning seasons of this project was completed through a data collection system, and various performance parameters of the system were studied and analyzed. The data was obtained using measured data from one year of system operation. The testing results show that the sewage temperature of the heat pump system in winter is approx. 13.5 degrees C, the hot water supply temperature is approx. 50 degrees C, the average COP of the unit is 3.95, and the average COP of the system is 2.96. The calculation results show that the heating energy consumption of the heat pump unit is only 50.81% of that of a traditional heating mode coal-fired boiler and 57.57% of that of an air source heat pump system. In summer, the sewage temperature is approx. 22 degrees C, the cold-water supply temperature is approx. 5.5 degrees C, the average COP of the unit is 4.45, and the average COP of the system is 3.25. The cooling energy consumption of the heat pump system is 79.39% of the energy consumption of the traditional chiller and 61.56% of the cooling energy consumption of the air source heat pump system. This shows that the sewage source heat pump system has a remarkable energy-saving effect.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Application of a heat pump system using untreated urban sewage as a heat source
    Liu, Zhibin
    Ma, Liangdong
    Zhang, Jili
    APPLIED THERMAL ENGINEERING, 2014, 62 (02) : 747 - 757
  • [2] Application of a heat pump system using untreated urban sewage as a heat source
    Liu, Zhibin
    Ma, Liangdong
    Zhang, Jili
    Applied Thermal Engineering, 2013, 61 (02) : 747 - 757
  • [3] System simulation of an untreated sewage source heat pump
    Qin N.
    Hao Z.
    International Journal of Simulation: Systems, Science and Technology, 2016, 17 (29): : 27.1 - 27.9
  • [4] Heating Transfer Characteristics Analysis on the Flooded Refrigerant Evaporator Using Untreated Sewage Heat Energy
    Zhuang, Zhaoyi
    Pang, Haiying
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 3: BUILDING SIMULATION AND INFORMATION MANAGEMENT, 2014, 263 : 137 - 145
  • [5] Combined system of solar heating and cooling using heat pump
    Zakhidov R.A.
    Anarbaev A.I.
    Zakhidov, R.A., 1600, Allerton Press Incorporation (50): : 178 - 183
  • [6] Energy Recovery from Wastewater: A Study on Heating and Cooling of a Multipurpose Building with Sewage-Reclaimed Heat Energy
    Cecconet, Daniele
    Racek, Jakub
    Callegari, Arianna
    Hlavinek, Petr
    SUSTAINABILITY, 2020, 12 (01)
  • [7] Analysis on Sewage Source Heat Pump Applications in the Building Energy Saving
    Liu, Xueting
    Yang, Dong
    Lou, Zaiqiang
    Zhang, Yunting
    SUSTAINABLE ENVIRONMENT AND TRANSPORTATION, PTS 1-4, 2012, 178-181 : 135 - +
  • [8] Energy analysis of a building solar heat pump system
    Fu, ZR
    Luo, XH
    Yang, LD
    Li, NP
    Yang, ZA
    ENERGY & ENVIRONMENT - A WORLD OF CHALLENGES AND OPPORTUNITIES, PROCEEDINGS, 2003, : 225 - 229
  • [9] Thermo-economic assessments on building heating by a sewage source heat pump coupled with heat storage system
    Ma, Jinxing
    Zhang, Xiaogang
    Yu, Jiabang
    Wei, Pan
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 53
  • [10] Modeling and performance analysis of the condenser using untreated sewage heat energy
    Zhuang, Zhaoyi
    Du, Yongjie
    Li, Yongbin
    Wang, Yingjie
    8TH INTERNATIONAL COLD CLIMATE HVAC CONFERENCE, 2016, 146 : 334 - 341