Estimation of renal function using iodine maps in dual-energy spectral computed tomography urography: a feasibility and accuracy study

被引:1
|
作者
Wang, Shigeng [1 ]
Tong, Xiaoyu [1 ]
Zhang, Jingyi [1 ]
Fan, Yong [1 ]
Wei, Wei [1 ]
Li, Jianying [2 ]
Liu, Yijun [1 ]
Hu, Mengting [1 ]
Chen, Qiye [1 ]
Liu, Lei [3 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, Lianhe Rd, Dalian, Peoples R China
[2] GE Healthcare, CT Res Ctr, Dalian, Peoples R China
[3] Dalian Med Univ, Affiliated Hosp 1, Urol, Dalian, Peoples R China
关键词
Dual-energy computed tomography; Urography; Iodine map; Glomerular filtration rate; GLOMERULAR-FILTRATION-RATE; CT; CREATININE; IMAGES;
D O I
10.1007/s00261-023-04146-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
<bold>Purpose: </bold>To explore the feasibility of measuring glomerular filtration rate (GFR) using iodine maps in dual-energy spectral computed tomography urography (DEsCTU) and correlate them with the estimated GFR (eGFR) based on the equation of creatinine-cystatin C.<bold>Materials and methods: </bold>One hundred and twenty-eight patients referred for DEsCTU were retrospectively enrolled. The DEsCTU protocol included non-contrast, nephrographic, and excretory phase imaging. The CT-derived GFR was calculated using the above 3-phase iodine maps (CT-GFR(iodine)) and 120 kVp-like images (CT-GFR(120kvp)) separately. CT-GFR(iodine) and CT-GFR(120kvp) were compared with eGFR using paired t-test, correlation analysis, and Bland-Altman plots. The receiver operating characteristic curves were used to test the renal function diagnostic performance with CT-GFR(120kvp) and CT-GFR(iodine).<bold>Results: </bold>The difference between eGFR (89.91 +/- 18.45 ml<middle dot>min(-1)<middle dot>1.73 m(-2)) as reference standard and CT-GFR(iodine) (90.06 +/- 20.89 ml<middle dot>min(-1)<middle dot>1.73 m(-2)) was not statistically significant, showing excellent correlation (r = 0.88, P < 0.001) and agreement (+/- 19.75 ml<middle dot>min(-1)<middle dot>1.73 m(-2), P = 0.866). The correlation between eGFR and CT-GFR(120kvp) (66.13 +/- 19.18 ml<middle dot>min(-1)<middle dot>1.73 m(-2)) was poor (r = 0.36, P < 0.001), and the agreement was poor (+/- 40.65 ml<middle dot>min(-1)<middle dot>1.73 m(-2), P < 0.001). There were 62 patients with normal renal function and 66 patients with decreased renal function based on eGFR. The CT-GFR(iodine) had the largest area under the curve (AUC) for distinguishing between normal and decreased renal function (AUC = 0.951).<bold>Conclusion: </bold>The GFR can be calculated accurately using iodine maps in DEsCTU. DEsCTU could be a non-invasive and reliable one-stop-shop imaging technique for evaluating both the urinary tract morphology and renal function.
引用
收藏
页码:997 / 1005
页数:9
相关论文
共 50 条
  • [31] Evaluation of Radiation Dose Effect on Lung Function Using Iodine Maps Derived from Serial Dual-Energy Computed Tomograms
    Zhang, S.
    Lapointe, A.
    Simard, M.
    Filion, E. J.
    Campeau, M. P.
    Roberge, D.
    Bouchard, H.
    Carrier, J. F.
    Blais, D.
    Bedwani, S.
    Bahig, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E366 - E367
  • [32] Application of Dual-Energy Spectral Computed Tomography to Thoracic Oncology Imaging
    Kim, Cherry
    Kim, Wooil
    Park, Sung-Joon
    Lee, Young Hen
    Hwang, Sung Ho
    Yong, Hwan Seok
    Oh, Yu-Whan
    Kang, Eun-Young
    Lee, Ki Yeol
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (07) : 838 - 850
  • [33] Detection of gallbladder stones by dual-energy spectral computed tomography imaging
    An-Liang Chen
    Ai-Lian Liu
    Sheng Wang
    Jing-Hong Liu
    Ye Ju
    Mei-Yu Sun
    Yi-Jun Liu
    World Journal of Gastroenterology, 2015, (34) : 9993 - 9998
  • [34] Feasibility Study to Demonstrate Cardiac Imaging using fast kVp switching dual-energy computed tomography: Phantom Study
    Madhav, Priti
    Imai, Yasuhiro
    Narayanan, Suresh
    Dutta, Sandeep
    Chandra, Naveen
    Hsieh, Jiang
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [35] A comprehensive review of dual-energy and multi-spectral computed tomography
    Garnett, Richard
    CLINICAL IMAGING, 2020, 67 : 160 - 169
  • [36] Detection of gallbladder stones by dual-energy spectral computed tomography imaging
    Chen, An-Liang
    Liu, Ai-Lian
    Wang, Sheng
    Liu, Jing-Hong
    Ju, Ye
    Sun, Mei-Yu
    Liu, Yi-Jun
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (34) : 9993 - 9998
  • [37] Radiomic Analysis of Pulmonary Nodules for Distinguishing Malignancy From Benignancy: The Value of Using Iodine Maps From Dual-Energy Computed Tomography
    Zhong, Yan
    Xu, Hai
    Zhang, Wei
    Li, Hai
    Yu, Tong-Fu
    Yuan, Mei
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (06) : 878 - 883
  • [38] Intraindividual Consistency of Iodine Concentration in Dual-Energy Computed Tomography of the Chest and Abdomen
    Zopfs, David
    Reimer, Robert Peter
    Sonnabend, Kristina
    Rinneburger, Miriam
    Hentschke, Clemens M.
    Persigehl, Thorsten
    Lennartz, Simon
    Grosse Hokamp, Nils
    INVESTIGATIVE RADIOLOGY, 2021, 56 (03) : 181 - 187
  • [39] The role of renal dual-energy computed tomography in exploring the gouty kidney: the RENODECT study
    Pascart, Tristan
    Dauphin, Elie
    Yokose, Chio
    Jauffret, Charlotte
    Pacaud, Aurore
    Laurent, Victor
    Ducoulombier, Vincent
    Choi, Hyon K.
    Budzik, Jean-Francois
    ANNALS OF MEDICINE, 2025, 57 (01)
  • [40] Disk injury in patients with vertebral fractures—a prospective diagnostic accuracy study using dual-energy computed tomography
    Matthias Pumberger
    Michael Fuchs
    Nils Engelhard
    Kay Geert Hermann
    Michael Putzier
    Marcus R. Makowski
    Bernd Hamm
    Torsten Diekhoff
    European Radiology, 2019, 29 : 4495 - 4502