Estimation of renal function using iodine maps in dual-energy spectral computed tomography urography: a feasibility and accuracy study

被引:1
|
作者
Wang, Shigeng [1 ]
Tong, Xiaoyu [1 ]
Zhang, Jingyi [1 ]
Fan, Yong [1 ]
Wei, Wei [1 ]
Li, Jianying [2 ]
Liu, Yijun [1 ]
Hu, Mengting [1 ]
Chen, Qiye [1 ]
Liu, Lei [3 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, Lianhe Rd, Dalian, Peoples R China
[2] GE Healthcare, CT Res Ctr, Dalian, Peoples R China
[3] Dalian Med Univ, Affiliated Hosp 1, Urol, Dalian, Peoples R China
关键词
Dual-energy computed tomography; Urography; Iodine map; Glomerular filtration rate; GLOMERULAR-FILTRATION-RATE; CT; CREATININE; IMAGES;
D O I
10.1007/s00261-023-04146-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
<bold>Purpose: </bold>To explore the feasibility of measuring glomerular filtration rate (GFR) using iodine maps in dual-energy spectral computed tomography urography (DEsCTU) and correlate them with the estimated GFR (eGFR) based on the equation of creatinine-cystatin C.<bold>Materials and methods: </bold>One hundred and twenty-eight patients referred for DEsCTU were retrospectively enrolled. The DEsCTU protocol included non-contrast, nephrographic, and excretory phase imaging. The CT-derived GFR was calculated using the above 3-phase iodine maps (CT-GFR(iodine)) and 120 kVp-like images (CT-GFR(120kvp)) separately. CT-GFR(iodine) and CT-GFR(120kvp) were compared with eGFR using paired t-test, correlation analysis, and Bland-Altman plots. The receiver operating characteristic curves were used to test the renal function diagnostic performance with CT-GFR(120kvp) and CT-GFR(iodine).<bold>Results: </bold>The difference between eGFR (89.91 +/- 18.45 ml<middle dot>min(-1)<middle dot>1.73 m(-2)) as reference standard and CT-GFR(iodine) (90.06 +/- 20.89 ml<middle dot>min(-1)<middle dot>1.73 m(-2)) was not statistically significant, showing excellent correlation (r = 0.88, P < 0.001) and agreement (+/- 19.75 ml<middle dot>min(-1)<middle dot>1.73 m(-2), P = 0.866). The correlation between eGFR and CT-GFR(120kvp) (66.13 +/- 19.18 ml<middle dot>min(-1)<middle dot>1.73 m(-2)) was poor (r = 0.36, P < 0.001), and the agreement was poor (+/- 40.65 ml<middle dot>min(-1)<middle dot>1.73 m(-2), P < 0.001). There were 62 patients with normal renal function and 66 patients with decreased renal function based on eGFR. The CT-GFR(iodine) had the largest area under the curve (AUC) for distinguishing between normal and decreased renal function (AUC = 0.951).<bold>Conclusion: </bold>The GFR can be calculated accurately using iodine maps in DEsCTU. DEsCTU could be a non-invasive and reliable one-stop-shop imaging technique for evaluating both the urinary tract morphology and renal function.
引用
收藏
页码:997 / 1005
页数:9
相关论文
共 50 条
  • [21] Accuracy of dual-energy computed tomography for the measurement of iodine concentration using cardiac CT protocols: validation in a phantom model
    James D. Koonce
    Rozemarijn Vliegenthart
    U. Joseph Schoepf
    Bernhard Schmidt
    Amy E. Wahlquist
    Paul J. Nietert
    Gorka Bastarrika
    Thomas G. Flohr
    Felix G. Meinel
    European Radiology, 2014, 24 : 512 - 518
  • [22] Accuracy of dual-energy computed tomography for the measurement of iodine concentration using cardiac CT protocols: validation in a phantom model
    Koonce, James D.
    Vliegenthart, Rozemarijn
    Schoepf, U. Joseph
    Schmidt, Bernhard
    Wahlquist, Amy E.
    Nietert, Paul J.
    Bastarrika, Gorka
    Flohr, Thomas G.
    Meinel, Felix G.
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 512 - 518
  • [23] Dual-Energy Computed Tomography for Stone Type Assessment: A Pilot Study of Dual-Energy Computed Tomography with Five Indices
    Rudenko, Vadim
    Serova, Natalia
    Kapanadze, Lida
    Taratkin, Mark
    Okhunov, Zhamshid
    Leonard, Stephen P.
    Ritter, Manuel
    Kriegmair, Maximilian
    Snurnitsyna, Olesya
    Kozlov, Vasiliy
    Laukhtina, Ekaterina
    Arshiev, Magomed
    Aleksandrova, Ksenia
    Salomon, Georg
    Enikeev, Dmitry
    Glybochko, Petr
    JOURNAL OF ENDOUROLOGY, 2020, 34 (09) : 893 - 899
  • [24] Virtual Monoenergetic Imaging and Iodine Perfusion Maps Improve Diagnostic Accuracy of Dual-Energy Computed Tomography Pulmonary Angiography With Suboptimal Contrast Attenuation
    Leithner, Doris
    Wichmann, Julian L.
    Vogl, Thomas J.
    Trommer, Jesko
    Martin, Simon S.
    Scholtz, Jan-Erik
    Bodelle, Boris
    De Cecco, Carlo N.
    Duguay, Taylor
    Nance, John W., Jr.
    Schoepf, U. Joseph
    Albrecht, Moritz H.
    INVESTIGATIVE RADIOLOGY, 2017, 52 (11) : 659 - 665
  • [25] Dual-Energy Computed Tomography Iodine Maps: Application in the Diagnosis of Periprosthetic Joint Infection in Total Hip Arthroplasty
    Cheng, Qiang
    Yang, Yaji
    Li, Feilong
    Li, Xiaobin
    Qin, Leilei
    Huang, Wei
    JOURNAL OF ARTHROPLASTY, 2025, 40 (02): : 499 - 505
  • [26] Efficacy of Iodine Perfusion Maps from Dual-energy Computed Tomography of the Pulmonary Arteries in Pulmonary Embolism Assessment
    Tan, S. Y.
    Lau, K.
    Borsaru, A.
    Jackson, D.
    Nandurkar, D.
    HONG KONG JOURNAL OF RADIOLOGY, 2019, 22 (04): : 243 - 248
  • [27] Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study
    Virgile Chevance
    Thibaud Damy
    Vania Tacher
    François Legou
    Fourat Ridouani
    Alain Luciani
    Hicham Kobeiter
    Alain Rahmouni
    Jean-François Deux
    European Radiology, 2018, 28 : 816 - 823
  • [28] Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study
    Chevance, Virgile
    Damy, Thibaud
    Tacher, Vania
    Legou, Francois
    Ridouani, Fourat
    Luciani, Alain
    Kobeiter, Hicham
    Rahmouni, Alain
    Deux, Jean-Francois
    EUROPEAN RADIOLOGY, 2018, 28 (02) : 816 - 823
  • [29] Accuracy of Quantification of Iodine and Hounsfield Unit Values on Virtual Monochromatic Imaging Using Dual-Energy Computed Tomography: Comparison of Dual-Layer Computed Tomography With Fast Kilovolt-Switching Computed Tomography
    Washio, Hayate
    Ohira, Shingo
    Karino, Tsukasa
    Nitta, Yuya
    Hayashi, Masaaki
    Miyazaki, Masayoshi
    Teshima, Teruki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 965 - 971
  • [30] The role of dual-energy computed tomography in the assessment of pulmonary function
    Hwang, Hye Jeon
    Hoffman, Eric A.
    Lee, Chang Hyun
    Goo, Jin Mo
    Levin, David L.
    Kauczor, Hans-Ulrich
    Seo, Joon Beom
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 86 : 320 - 334