The monolithic coupling of straight tube Coriolis mass flowmeter with liquid hydrogen

被引:1
|
作者
Pei, Xiangxiang [1 ]
Chen, Qiangfeng [2 ]
Sun, Shien [3 ]
Song, Yucai [2 ]
Qiu, Limin [1 ]
Zhang, Xiaobin [1 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Peoples R China
[2] Zhejiang Zheneng Fuxing Fuel Co Ltd, Hangzhou 310003, Peoples R China
[3] Zhejiang Energy Technol Res Inst Co Ltd, Hangzhou 310003, Peoples R China
关键词
Coriolis mass flowmeter; Liquid hydrogen; Fluid-structure interaction; Monolithic coupling method; Flow-induced vibration;
D O I
10.1016/j.cryogenics.2022.103625
中图分类号
O414.1 [热力学];
学科分类号
摘要
The Coriolis mass flowmeter (CMF) has the advantages of a simple structure and direct measurement of fluid mass flow rate. This paper numerically simulates the fluid-structure interaction (FSI) of a straight tube CMF based on the monolithic coupling methods of hydrodynamics and structural mechanics with liquid hydrogen (LH2) as the working fluid. The simulated time lag for the CMF with water is firstly compared with the results from the published experiment and the iterative partitioned coupling method to validate the model. The com-parison shows that the results of the monolithic coupling are closer to the experimental results. Then the monolithic coupling method is used to analyze the FSI characteristics of the CMF with LH2. And the general flow -induced vibration results with LH2 are presented for the straight tube CMF, including the dry and wet vibration modes. The velocity and the detector positions on the time lag are specially discussed. The results reveal the FSI characteristics of the straight tube CMF with LH2.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Effects of boundary conditions on phase shift of a dual-tube conveying fluid in the Coriolis mass flowmeter
    Javan, M. Vesaghati
    Navazi, H. M.
    JOURNAL OF FLUIDS AND STRUCTURES, 2023, 118
  • [42] Modal simulation and experiment analysis of coriolis mass flowmeter
    Zhao, Juan
    Li, Zhongxiang
    Zheng, Dezhi
    Fan, Shangchun
    JOURNAL OF ENGINEERING-JOE, 2019, 2019 (23): : 9013 - 9016
  • [43] Digital closed loop system of Coriolis mass flowmeter
    Xing, Weiwei
    Fan, Shangchun
    Zheng, Dezhi
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2006, 27 (05): : 461 - 465
  • [44] Coriolis mass flowmeter its present situation and future
    Wan, Buyan
    Kuangye Yanjiu Yu Kaifa/Mining Research and Development, 1995, 15 (04):
  • [45] Coriolis-mass-flowmeter with direct viscosity measurement
    Drahm, W
    Fuchs, M
    Bjönnes, H
    Matt, C
    Wenger, A
    Sprich, HJ
    TECHNISCHES MESSEN, 2004, 71 (03): : 148 - 153
  • [46] Large Size Straight-tube Coriolis Flowmeters
    Wang, Tao
    Hussain, Yousif
    MEASUREMENT & CONTROL, 2011, 44 (01): : 25 - 27
  • [47] Error Analysis and Accuracy Calibration Method of U-Tube Coriolis Mass Flowmeter Under Pulsating Flow
    Yang, Hai
    Zhang, Lizao
    Li, Li
    Liang, Haibo
    Zou, Jialing
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [48] Study on error caused by density effect of Coriolis mass flowmeter
    School of Manufacturing Sci. and Eng., Sichuan Univ., Chengdu 610065, China
    不详
    Sichuan Daxue Xuebao (Gongcheng Kexue Ban), 2013, 5 (138-144):
  • [49] Effect of fluid pressure on Coriolis mass flowmeter's performance
    Cascetta, F
    ISA TRANSACTIONS, 1996, 35 (04) : 365 - 370
  • [50] Fluid-structure interaction analysis of coriolis mass flowmeter
    Huang, Tian-Xing
    Reny, Jian-Xin
    Zhangz, Pei
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2020, 34 (14-16):