The monolithic coupling of straight tube Coriolis mass flowmeter with liquid hydrogen

被引:1
|
作者
Pei, Xiangxiang [1 ]
Chen, Qiangfeng [2 ]
Sun, Shien [3 ]
Song, Yucai [2 ]
Qiu, Limin [1 ]
Zhang, Xiaobin [1 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Peoples R China
[2] Zhejiang Zheneng Fuxing Fuel Co Ltd, Hangzhou 310003, Peoples R China
[3] Zhejiang Energy Technol Res Inst Co Ltd, Hangzhou 310003, Peoples R China
关键词
Coriolis mass flowmeter; Liquid hydrogen; Fluid-structure interaction; Monolithic coupling method; Flow-induced vibration;
D O I
10.1016/j.cryogenics.2022.103625
中图分类号
O414.1 [热力学];
学科分类号
摘要
The Coriolis mass flowmeter (CMF) has the advantages of a simple structure and direct measurement of fluid mass flow rate. This paper numerically simulates the fluid-structure interaction (FSI) of a straight tube CMF based on the monolithic coupling methods of hydrodynamics and structural mechanics with liquid hydrogen (LH2) as the working fluid. The simulated time lag for the CMF with water is firstly compared with the results from the published experiment and the iterative partitioned coupling method to validate the model. The com-parison shows that the results of the monolithic coupling are closer to the experimental results. Then the monolithic coupling method is used to analyze the FSI characteristics of the CMF with LH2. And the general flow -induced vibration results with LH2 are presented for the straight tube CMF, including the dry and wet vibration modes. The velocity and the detector positions on the time lag are specially discussed. The results reveal the FSI characteristics of the straight tube CMF with LH2.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Development of Small Size Coriolis Mass Flowmeter
    Ki-Won, Lim
    Jueng-Keun, Ji
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2006, 30 (06) : 497 - 504
  • [32] Analytical calculation of sensitivity for Coriolis mass flowmeter
    Wang, L. J.
    Hu, L.
    Zhu, Z. C.
    Ye, P.
    Fu, X.
    MEASUREMENT, 2011, 44 (06) : 1117 - 1127
  • [33] Performance study of Coriolis mass flowmeter for hydrogen two-phase flow measurement
    Pei, Xiangxiang
    Zhang, Xiaobin
    JOURNAL OF FLUIDS AND STRUCTURES, 2025, 133
  • [34] Ultrahigh performance of Ti-based glassy alloy tube sensor for Coriolis mass flowmeter
    Ma Chao-li
    Inoue, A.
    Zhang Tao
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2006, 16 : S202 - S205
  • [35] Investigation of the batch measurement errors for single-straight tube Coriolis mass flowmeters
    Wang, Tao
    Hussain, Yousif
    FLOW MEASUREMENT AND INSTRUMENTATION, 2006, 17 (06) : 383 - 390
  • [36] FIBRE-OPTIC CORIOLIS MASS FLOWMETER FOR LIQUIDS
    WADE, CA
    DANDRIDGE, A
    ELECTRONICS LETTERS, 1988, 24 (13) : 783 - 785
  • [37] A new signal processing method for Coriolis mass flowmeter
    Xu, K.
    Ni, W.
    Jiliang Xuebao/Acta Metrologica Sinica, 2001, 22 (04): : 254 - 258
  • [38] Flatness-based control of a coriolis mass flowmeter
    Automation and Control Engineering, Christian-Albrechts-University, 24143 Kiel, Germany
    不详
    Key Eng Mat, 2008, (465-468): : 465 - 468
  • [39] Using Coriolis Mass Flowmeter for Wet Gas Metering
    Geng, Yanfeng
    Yeung, Hoi
    Cao, Yi
    Xing, Lanchang
    Zhu, Hao
    Drahm, Wolfgang
    MEASUREMENT & CONTROL, 2010, 43 (06): : 183 - 185
  • [40] Digital signal processing method of Coriolis mass flowmeter
    Zhang Haitao
    Tu Yaqing
    Niu Penghui
    Proceedings of the First International Symposium on Test Automation & Instrumentation, Vols 1 - 3, 2006, : 466 - 470