The monolithic coupling of straight tube Coriolis mass flowmeter with liquid hydrogen

被引:1
|
作者
Pei, Xiangxiang [1 ]
Chen, Qiangfeng [2 ]
Sun, Shien [3 ]
Song, Yucai [2 ]
Qiu, Limin [1 ]
Zhang, Xiaobin [1 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Peoples R China
[2] Zhejiang Zheneng Fuxing Fuel Co Ltd, Hangzhou 310003, Peoples R China
[3] Zhejiang Energy Technol Res Inst Co Ltd, Hangzhou 310003, Peoples R China
关键词
Coriolis mass flowmeter; Liquid hydrogen; Fluid-structure interaction; Monolithic coupling method; Flow-induced vibration;
D O I
10.1016/j.cryogenics.2022.103625
中图分类号
O414.1 [热力学];
学科分类号
摘要
The Coriolis mass flowmeter (CMF) has the advantages of a simple structure and direct measurement of fluid mass flow rate. This paper numerically simulates the fluid-structure interaction (FSI) of a straight tube CMF based on the monolithic coupling methods of hydrodynamics and structural mechanics with liquid hydrogen (LH2) as the working fluid. The simulated time lag for the CMF with water is firstly compared with the results from the published experiment and the iterative partitioned coupling method to validate the model. The com-parison shows that the results of the monolithic coupling are closer to the experimental results. Then the monolithic coupling method is used to analyze the FSI characteristics of the CMF with LH2. And the general flow -induced vibration results with LH2 are presented for the straight tube CMF, including the dry and wet vibration modes. The velocity and the detector positions on the time lag are specially discussed. The results reveal the FSI characteristics of the straight tube CMF with LH2.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Measuring tube structure optimization of coriolis mass flowmeter with liquid hydrogen
    Pei, Xiangxiang
    Yu, Lianyan
    Li, Xiang
    Xu, Haohao
    Zhang, Xiaobin
    FLOW MEASUREMENT AND INSTRUMENTATION, 2024, 97
  • [2] Research for theoretical model of straight tube Coriolis mass flowmeter
    Zhou, Yongquan
    Zheng, Ronggen
    Zhao, Xueduan
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 1995, 16 (03): : 243 - 248
  • [3] Calculation of the sensitivity of a straight tube Coriolis mass flowmeter with free ends
    Hemp, J
    FLOW MEASUREMENT AND INSTRUMENTATION, 2002, 12 (5-6) : 411 - 420
  • [4] Coriolis mass flowmeter with a single straight tube and electronical correction of vibrations
    Rieder, A
    TECHNISCHES MESSEN, 1999, 66 (04): : 156 - 162
  • [5] Theoretical and Numerical Analysis of U-Tube Coriolis Mass Flowmeter with Liquid Hydrogen
    Xiangxiang, Pei
    Qiangfeng, Chen
    Yucai, Song
    Xiaobin, Zhang
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2024, 57 (09): : 992 - 1000
  • [6] Twin rigid straight pipe coriolis mass flowmeter
    Adiletta, Giovanni
    Cascetta, Furio
    Valley, Sergio della
    Pagano, Stefano
    Vigo, Paolo
    Measurement: Journal of the International Measurement Confederation, 1993, 11 (04): : 289 - 308
  • [7] Single, straight-tube mass flowmeter
    不详
    HYDROCARBON PROCESSING, 1999, 78 (01): : 113 - 113
  • [8] Resonant Coriolis mass flowmeter
    Fan, S.C.
    Liu, G.J.
    Song, Z.S.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2000, 26 (06): : 653 - 655
  • [9] Largest Coriolis mass flowmeter
    不详
    HYDROCARBON PROCESSING, 2008, 87 (03): : 26 - +
  • [10] MODELING OF THE CORIOLIS MASS FLOWMETER
    SULTAN, G
    HEMP, J
    JOURNAL OF SOUND AND VIBRATION, 1989, 132 (03) : 473 - 489