Reliability and Measurement Error of Breast Volume Calculation Using Three-Dimensional Surface Imaging

被引:1
|
作者
Fearn, Nicola [1 ]
Meybodi, Farid [2 ,3 ]
Kilbreath, Sharon [1 ]
Dylke, Elizabeth [1 ]
Llanos, Catalina [3 ]
Swanton, Carmen [4 ]
Stuart, Kirsty [2 ,3 ,4 ,5 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Sydney Sch Hlth Sci, Sydney, Australia
[2] Univ Sydney, Sydney Med Sch, Sydney, Australia
[3] Westmead Hosp, Westmead Breast Canc Inst, Sydney, Australia
[4] Westmead Hosp, Crown Princess Mary Canc Ctr, Dept Radiat Oncol, Sydney, Australia
[5] Westmead Hosp, Westmead Breast Canc Inst, POB 143, Sydney, NSW 2145, Australia
关键词
reliability; breast volume; measurement properties; 3D surface imaging; breast lymphedema; VECTRA-XT; CONSERVING SURGERY; MASTECTOMY;
D O I
10.1089/lrb.2022.0015
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Breast lymphedema after breast cancer is challenging to quantify. Three-dimensional (3D) surface imaging is one available technique to measure breast volume, however, the measurement properties of available software programs have not been fully determined. The aim of this study was to determine equivalency of measurements with two software programs as well as reliability, standard error of measurement (SEM), and smallest detectable change (SDC). Methods and Results: Retrospective three-dimensional surface imaging (3D-SI) of 100 breasts taken before or after breast conserving surgery for breast cancer were retrieved for reliability analysis. Three assessors followed a standardized measurement technique using two software programs, Vectra (R) 3D Analysis Module (VAM) and Breast Sculptor (R). Mean breast volume was 489.9 +/- 206 cc using VAM and 480.1 +/- 229.1 cc using Breast Sculptor. Lin's concordance showed poor agreement between programs (0.81-0.88). Measurements using VAM had excellent intra- and inter-rater reliability with SEM = 4.1% for one assessor and 8.7% for multiple assessors. Breast Sculptor also had excellent intra-rater and substantial inter-rater reliability but the SEM was much larger at 14.5% (intra-rater) and 19.1% (inter-rater). The SDC value was lowest for VAM and a single rater with 56 cc indicating a meaningful change beyond measurement error. Conclusion: Breast volume measurements captured with 3D-SI using VECTRA-XT are highly reliable, but the volumes, SEM, and SDC varied between the two software programs. Measurement error was lowest with VAM software. Although the usefulness of VECTRA-XT and VAM software to detect change in breast volume is promising, further solutions to reduce measurement error are required to improve clinical utility to measure breast lymphedema.
引用
收藏
页码:296 / 303
页数:8
相关论文
共 50 条
  • [41] THREE-DIMENSIONAL SURFACE MEASUREMENT BY SPACE ENCODING RANGE IMAGING.
    Sato, Kosuke
    Inokuchi, Seiji
    1600, (02):
  • [42] Three-dimensional Ultrasound Elasticity Imaging on an Automated Breast Volume Scanning System
    Wang, Yuqi
    Nasief, Haidy G.
    Kohn, Sarah
    Milkowski, Andy
    Clary, Tom
    Barnes, Stephen
    Barbone, Paul E.
    Hall, Timothy J.
    ULTRASONIC IMAGING, 2017, 39 (06) : 369 - 392
  • [43] The interobserver reliability and validity of volume calculation from three-dimensional ultrasound datasets in the in vitro setting
    Raine-Fenning, NJ
    Clewes, JS
    Kendall, NR
    Bunkheila, AK
    Campbell, BK
    Johnson, IR
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 21 (03) : 283 - 291
  • [44] Serial fetal lung volume measurement using three-dimensional ultrasound
    Bahmaie, A
    Hughes, SW
    Clark, T
    Milner, A
    Saunders, J
    Tilling, K
    Maxwell, DJ
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (02) : 154 - 158
  • [45] Thalamic volume measurement in normal fetuses using three-dimensional sonography
    Sotiriadis, Alexandros
    Dimitrakopoulos, Ioannis
    Eleftheriades, Makarios
    Agorastos, Theodoros
    Makrydimas, George
    JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (04) : 207 - 213
  • [46] Discussion: Automated Measurement of Intracranial Volume Using Three-Dimensional Photography
    Taylor, Jesse A.
    Shakir, Sameer
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 146 (03) : 324E - 325E
  • [47] Three-dimensional US of the fetus: Volume imaging
    Benacerraf, BR
    Shipp, TD
    Bromley, B
    RADIOLOGY, 2006, 238 (03) : 988 - 996
  • [48] Volume holographic imaging of three-dimensional objects
    Barbastathis, G
    Brady, DJ
    DIFFRACTIVE AND HOLOGRAPHIC TECHNOLOGIES, SYSTEMS, AND SPATIAL LIGHT MODULATORS VI, 1999, 3633 : 170 - 181
  • [49] Concrete Surface Damage Volume Measurement Based on Three-Dimensional Reconstruction by Smartphones
    Liu, Chengcheng
    Zhou, Lei
    Wang, Weiwei
    Zhao, Xuefeng
    IEEE SENSORS JOURNAL, 2021, 21 (10) : 11349 - 11360
  • [50] Three-Dimensional Surface Analysis for Preoperative Prediction of Breast Volume: A Validation Study
    Stern, Carrie S.
    Plotsker, Ethan L.
    Rubenstein, Robyn
    Mehrara, Ellie
    Haglich, Kathryn
    Zoghbi, Yasmina
    Mehrara, Babak J.
    Nelson, Jonas A.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2023, 152 (06) : 1153 - 1162