Reliability and Measurement Error of Breast Volume Calculation Using Three-Dimensional Surface Imaging

被引:1
|
作者
Fearn, Nicola [1 ]
Meybodi, Farid [2 ,3 ]
Kilbreath, Sharon [1 ]
Dylke, Elizabeth [1 ]
Llanos, Catalina [3 ]
Swanton, Carmen [4 ]
Stuart, Kirsty [2 ,3 ,4 ,5 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Sydney Sch Hlth Sci, Sydney, Australia
[2] Univ Sydney, Sydney Med Sch, Sydney, Australia
[3] Westmead Hosp, Westmead Breast Canc Inst, Sydney, Australia
[4] Westmead Hosp, Crown Princess Mary Canc Ctr, Dept Radiat Oncol, Sydney, Australia
[5] Westmead Hosp, Westmead Breast Canc Inst, POB 143, Sydney, NSW 2145, Australia
关键词
reliability; breast volume; measurement properties; 3D surface imaging; breast lymphedema; VECTRA-XT; CONSERVING SURGERY; MASTECTOMY;
D O I
10.1089/lrb.2022.0015
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Breast lymphedema after breast cancer is challenging to quantify. Three-dimensional (3D) surface imaging is one available technique to measure breast volume, however, the measurement properties of available software programs have not been fully determined. The aim of this study was to determine equivalency of measurements with two software programs as well as reliability, standard error of measurement (SEM), and smallest detectable change (SDC). Methods and Results: Retrospective three-dimensional surface imaging (3D-SI) of 100 breasts taken before or after breast conserving surgery for breast cancer were retrieved for reliability analysis. Three assessors followed a standardized measurement technique using two software programs, Vectra (R) 3D Analysis Module (VAM) and Breast Sculptor (R). Mean breast volume was 489.9 +/- 206 cc using VAM and 480.1 +/- 229.1 cc using Breast Sculptor. Lin's concordance showed poor agreement between programs (0.81-0.88). Measurements using VAM had excellent intra- and inter-rater reliability with SEM = 4.1% for one assessor and 8.7% for multiple assessors. Breast Sculptor also had excellent intra-rater and substantial inter-rater reliability but the SEM was much larger at 14.5% (intra-rater) and 19.1% (inter-rater). The SDC value was lowest for VAM and a single rater with 56 cc indicating a meaningful change beyond measurement error. Conclusion: Breast volume measurements captured with 3D-SI using VECTRA-XT are highly reliable, but the volumes, SEM, and SDC varied between the two software programs. Measurement error was lowest with VAM software. Although the usefulness of VECTRA-XT and VAM software to detect change in breast volume is promising, further solutions to reduce measurement error are required to improve clinical utility to measure breast lymphedema.
引用
收藏
页码:296 / 303
页数:8
相关论文
共 50 条
  • [21] Three-dimensional anthropometry: reliability and error.
    Feathers, D
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2002, : 69 - 69
  • [22] Preoperative breast volume evaluation of one-stage immediate breast reconstruction using three-dimensional surface imaging and a printed mold
    Chen, Keng
    Feng, Chin-Jung
    Ma, Hsu
    Hsiao, Fu-Yin
    Tseng, Ling-Ming
    Tsai, Yi-Fang
    Lin, Yen-Shu
    Huang, Li-Ying
    Yu, Wen-Chan
    Perng, Cherng-Kang
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2019, 82 (09) : 732 - 739
  • [23] Three-dimensional measurement of bubble volume based on dual perspective imaging
    薛婷
    张少杰
    吴斌
    Optoelectronics Letters, 2017, 13 (01) : 70 - 73
  • [24] Three-dimensional measurement of bubble volume based on dual perspective imaging
    Xue T.
    Zhang S.-J.
    Wu B.
    Optoelectronics Letters, 2017, 13 (1) : 70 - 73
  • [25] Three-dimensional breast volume assessment
    Gouveia, P.
    Monteiro, J. P.
    Oliveira, H. P.
    Cardoso, M. J.
    Cardoso, J. S.
    EUROPEAN JOURNAL OF CANCER, 2016, 57 : S75 - S75
  • [26] A simplified three-dimensional volume measurement technique in keloid scars: Validity and reliability
    van der Aa, T.
    Verhiel, S. H. W. L.
    Erends, M.
    de Grzymala, A. A. Piatkowski
    Van den Kerckhove, E.
    Colla, C.
    van der Hulst, R. R. W. J.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2015, 68 (11): : 1574 - 1580
  • [27] Reliability and validity of tissue volume measurement by three-dimensional ultrasound: an experimental model
    Martins, W. P.
    Ferriani, R. A.
    Barra, D. A.
    Dos Reis, R. M.
    Bortolieiro, M. A. V.
    Nastri, C. O.
    Mauad Filho, F.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (02) : 210 - 214
  • [28] Three-Dimensional Volume Imaging in Gynecology
    Benacerraf, Beryl R.
    OBSTETRICS AND GYNECOLOGY CLINICS OF NORTH AMERICA, 2019, 46 (04) : 755 - +
  • [29] Validity and reliability of three-dimensional imaging to measure limb volume: A systematic review
    Kremer, Rachel L.
    Wolfe, Madison E.
    Brueckner, Noah J.
    Viola, Michaela C.
    Fisher, Mary Insana
    PHYSICAL THERAPY REVIEWS, 2020, 25 (01) : 21 - 28
  • [30] Automated Measurement of Intracranial Volume Using Three-Dimensional Photography
    Tu, Liyun
    Porras, Antonio R.
    Enquobahrie, Andinet
    Buck, Graham C.
    Tsering, Deki
    Horvath, Samantha
    Keating, Robert
    Oh, Albert K.
    Rogers, Gary F.
    George Linguraru, Marius
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 146 (03) : 314E - 323E