Shear properties of composite steel plate connectors for prefabricated steel-concrete composite beams

被引:3
|
作者
Jiang, Jinlong [1 ,2 ]
Zhou, Zhixiang [1 ,2 ,3 ]
Wang, Hongjie [1 ,2 ]
Zou, Yang [1 ,2 ]
Zhang, Zhongya [1 ,2 ]
Liang, Huaping [4 ]
机构
[1] Chongqing Jiaotong Univ, Sch Civil Engn, Chongqing 400074, Peoples R China
[2] Chongqing Jiaotong Univ, State Key Lab Mt Bridge & Tunnel Engn, Chongqing 400074, Peoples R China
[3] Shenzhen Univ, Coll Civil & Transportat Engn, Shenzhen 518060, Guangdong, Peoples R China
[4] Hainan Prov Rd Bridge Construct Investment Co Ltd, Haikou 570203, Hainan, Peoples R China
基金
中国国家自然科学基金;
关键词
Bridge engineering; Prefabricated steel-concrete composite beams; Composite steel plate connectors; Push -out test; Shear capacity; STRENGTH; BEHAVIOR; PERFORMANCE; CHANNEL;
D O I
10.1016/j.istruc.2023.105360
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As a critical component of prefabricated steel-concrete composite beams, ideal connectors can ensure the mechanical properties of bridges and significantly improve the efficiency of assembly construction. CSPC connector (Composite steel plate connector) with excellent load-slip curve and assembly construction efficiency was designed to realize fast and simple assembly construction. CSPC connectors require prefabricated bridge deck with no holes and low installation accuracy requirements. The results of 6 push-out specimens and 12 finite element models show that the CSPC connector exhibits an excellent load-slip curve compared to the existing connectors, and its shear stiffness and ductility coefficient are 1.03 and 1.51 times that of the stud connector, respectively. The shear stiffness and shear capacity of CSPC connectors are 0.79 times and 0.96 times the original when the grouting material age is reduced from 28 days to 3 days due to the rapid construction demand. The weakening of shear capacity is not obvious. The shear capacity of the CSPC connector comes from the connection between high-strength bolts and composite steel plates. The pressure-bearing effect of grouting material is crucial in connecting composite steel plates. Meanwhile, the composite steel plate of CSPC connector should be designed with equal thickness, a height of 30 mm and a spacing of no more than 10 mm. The recommended ratio of highstrength bolt diameter to composite steel plate thickness is 1.25. Finally, fit the load-slip relationship of CSPC connector, and propose a shear capacity formula with a deviation of less than 12 % from the test results.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Behavior of channel connectors in steel-concrete composite beams with precast slabs
    Arikoglu, Pinar
    Baran, Eray
    Topkaya, Cem
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 172
  • [42] Investigation of Shear Behavior in High-Strength Bolt Connectors for Steel-Concrete Composite Beams
    Li, Wei
    Wang, Jie
    Xing, Xiaobo
    Liu, Huining
    Di, Jin
    Sun, Xianchao
    Li, Leibo
    Li, Hongwei
    Qin, Fengjiang
    MATERIALS, 2024, 17 (24)
  • [43] Experimental evaluation of a novel demountable shear connection system in prefabricated steel-concrete composite beams
    Yang, Hailin
    Yu, Pengcheng
    Zheng, Yan
    CONSTRUCTION AND BUILDING MATERIALS, 2025, 470
  • [44] Longitudinal shear resistance of steel-concrete composite slabs with perfobond shear connectors
    Jeong, Youn-Ju
    Kim, Hyeong-Yeol
    Koo, Hyun-Bon
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (01) : 81 - 88
  • [45] Strengthening of existing composite steel-concrete beams utilising bolted shear connectors and welded studs
    Pathirana, Sameera Wijesiri
    Uy, Brian
    Mirza, Olivia
    Zhu, Xinqun
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 114 : 417 - 430
  • [46] Shear performance of C-shaped perforated angle connectors in steel-concrete composite beams
    Sakhri, Nafissa
    Ihaddoudene, Abd-Nacer Touati
    Saidani, Messaoud
    Da Costa-Neves, Luis Filipe
    STRUCTURES, 2025, 74
  • [47] EFFECTS OF STRAIN REGIMES ON THE BEHAVIOUR OF HEADED STUD SHEAR CONNECTORS FOR COMPOSITE STEEL-CONCRETE BEAMS
    Mirza, O.
    Uy, B.
    ADVANCED STEEL CONSTRUCTION, 2010, 6 (01): : 635 - 661
  • [48] Experimental study on longitudinal shear behavior of prefabricated steel-concrete composite beams with notched connections
    Huang, Da
    Nie, Xin
    Fan, Jiansheng
    Ding, Ran
    ENGINEERING STRUCTURES, 2024, 300
  • [49] Performances of Steel-Concrete Composite Construction with Demountable Shear Connectors - Review
    Al-Muslihand, Abdulhadi Th.
    Al-Hadithy, Laith Kh.
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENGINEERING TECHNIQUES (ICSET 2019), 2019, 518
  • [50] Mechanical behavior of steel-concrete composite decks with perfobond shear connectors
    Allahyari, Hamed
    Dehestani, Mehdi
    Beygi, Morteza H. A.
    Neya, Bahram Navayi
    Rahmani, Ebrahim