Shear properties of composite steel plate connectors for prefabricated steel-concrete composite beams

被引:3
|
作者
Jiang, Jinlong [1 ,2 ]
Zhou, Zhixiang [1 ,2 ,3 ]
Wang, Hongjie [1 ,2 ]
Zou, Yang [1 ,2 ]
Zhang, Zhongya [1 ,2 ]
Liang, Huaping [4 ]
机构
[1] Chongqing Jiaotong Univ, Sch Civil Engn, Chongqing 400074, Peoples R China
[2] Chongqing Jiaotong Univ, State Key Lab Mt Bridge & Tunnel Engn, Chongqing 400074, Peoples R China
[3] Shenzhen Univ, Coll Civil & Transportat Engn, Shenzhen 518060, Guangdong, Peoples R China
[4] Hainan Prov Rd Bridge Construct Investment Co Ltd, Haikou 570203, Hainan, Peoples R China
基金
中国国家自然科学基金;
关键词
Bridge engineering; Prefabricated steel-concrete composite beams; Composite steel plate connectors; Push -out test; Shear capacity; STRENGTH; BEHAVIOR; PERFORMANCE; CHANNEL;
D O I
10.1016/j.istruc.2023.105360
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As a critical component of prefabricated steel-concrete composite beams, ideal connectors can ensure the mechanical properties of bridges and significantly improve the efficiency of assembly construction. CSPC connector (Composite steel plate connector) with excellent load-slip curve and assembly construction efficiency was designed to realize fast and simple assembly construction. CSPC connectors require prefabricated bridge deck with no holes and low installation accuracy requirements. The results of 6 push-out specimens and 12 finite element models show that the CSPC connector exhibits an excellent load-slip curve compared to the existing connectors, and its shear stiffness and ductility coefficient are 1.03 and 1.51 times that of the stud connector, respectively. The shear stiffness and shear capacity of CSPC connectors are 0.79 times and 0.96 times the original when the grouting material age is reduced from 28 days to 3 days due to the rapid construction demand. The weakening of shear capacity is not obvious. The shear capacity of the CSPC connector comes from the connection between high-strength bolts and composite steel plates. The pressure-bearing effect of grouting material is crucial in connecting composite steel plates. Meanwhile, the composite steel plate of CSPC connector should be designed with equal thickness, a height of 30 mm and a spacing of no more than 10 mm. The recommended ratio of highstrength bolt diameter to composite steel plate thickness is 1.25. Finally, fit the load-slip relationship of CSPC connector, and propose a shear capacity formula with a deviation of less than 12 % from the test results.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Bolted shear connectors in steel-concrete composite structures: Shear behavior
    Liu, Xiaoyang
    Bi, Zijian
    Hu, Jingyu
    Hao, Hongsheng
    Lin, Zhansheng
    Li, Hongwei
    Xie, Yuanbin
    Zhao, Kai
    Jing, Yucai
    Yang, Guotao
    STRUCTURES, 2023, 58
  • [32] Behaviour of headed stud shear connectors for composite steel-concrete beams at elevated temperatures
    Mirza, O.
    Uy, B.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (03) : 662 - 674
  • [33] Mechanical properties of composite dowel shear connectors in corrugated steel-concrete composite bridge decks
    Huang P.
    Kong F.
    Peng S.
    Mei K.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2021, 51 (02): : 249 - 255
  • [34] Research Progress of Prefabricated Steel-Concrete Composite Shear Wall
    Liang, Wentao
    Yang, Yuanlong
    Liu, Yufei
    He, Longfu
    Hu, Hui
    PROCEEDINGS OF THE 2024 8TH INTERNATIONAL CONFERENCE ON CIVIL ARCHITECTURE AND STRUCTURAL ENGINEERING, ICCASE 2024, 2024, 33 : 597 - 603
  • [35] Study on composite beams with prefabricated steel bar truss concrete slabs and demountable shear connectors
    Du, Hao
    Hu, Xiamin
    Meng, Yanfei
    Han, Guohui
    Guo, Kaikai
    ENGINEERING STRUCTURES, 2020, 210
  • [36] Experimental and Numerical Analysis of Steel-Block Shear Connectors in Assembled Monolithic Steel-Concrete Composite Beams
    Wang, Yu-Hang
    Yu, Jie
    Liu, Jiepeng
    Chen, Y. Frank
    JOURNAL OF BRIDGE ENGINEERING, 2019, 24 (05)
  • [37] Interface shear resistance of steel-concrete composite beams using U-bolt shear connectors
    Gao, Shan
    Bai, Qi
    Guo, Lanhui
    Kang, Shao-Bo
    ENGINEERING STRUCTURES, 2023, 286
  • [38] 08.33: Full scale test on steel-concrete composite beams: Investigation of innovative shear connectors
    Kovács, Nauzika
    Kövesdi, Balázs
    Kachichian, Mansour
    Frank, Máté Ferenc
    ce/papers, 2017, 1 (2-3) : 2100 - 2109
  • [39] SHEAR CONNECTORS IN STEEL-CONCRETE COMPOSITE BEAMS FOR BRIDGES AND NEW CP 117 .2.
    MAINSTONE, RJ
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS, 1967, 38 (SEP): : 83 - +
  • [40] The Use of Shear Connectors for Enhancing the Performance of Steel-Concrete Composite Beams: Experimental and Numerical Assessment
    Daou, Anas
    Mahayri, Abdul Rahman
    Daou, Yehia
    Baalbaki, Oussama
    Khatib, Milad
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2021, 21 (06) : 1966 - 1976