Standard internal limiting membrane peeling versus internal limiting membrane abrasion technique for primary epiretinal membrane surgery

被引:1
|
作者
Bagci, Fatma [1 ]
Citirik, Mehmet [1 ]
Dulger, Selda Celik [1 ]
Teke, Mehmet Yasin [1 ]
机构
[1] Univ Hlth Sci, Ulucanlar Eye Training & Res Hosp, Ankara, Turkiye
关键词
Epiretinal membrane; Vitrectomy; Diamond-dusted membrane scraper; OPTICAL COHERENCE TOMOGRAPHY; THICKNESS MACULAR HOLE; FIBER LAYER APPEARANCE; INDOCYANINE GREEN; REMOVAL; VITRECTOMY; PUCKER;
D O I
10.5935/0004-2749.2021-0208
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
| Purposes: The purpose of this study is to compare the standard inner limiting membrane peeling technique to the inner limiting membrane abrasion technique with respect to visual outcomes and central retinal thickness in the primary epiretinal membrane surgery. Methods: A total of 59 eyes from 57 epiretinal membrane patients were separated into two groups including the standard inner limiting membrane peeling group and the inner limiting membrane peeling with abrasion technique group. At 6, 12, and 24 months of follow-up, the mean alteration in best-corrected visual acuity and central retinal thickness were assessed for each group. Results: The study includes 32 (54%) standard inner peeling and 27 (46%) inner limiting membrane peeling with abrasion technique patients. The mean preoperative logMAR best-corrected visual acuity for the standard inner limiting membrane peeling and inner limiting membrane peeling with abrasion groups was 0.73 (+/- 0.29) and 0.61 (+/- 0.3) respectively. At 6, 12, and 24 months of follow-up, the best-corrected visual acuity improved significantly in each group. At each period of observation, the alteration in best-corrected visual acuity was not statistically significant (p=0.54, p=0.52, p=0.67). When comparing the alterations between the standard inner limiting membrane peeling and inner limiting membrane peeling with abrasion technique groups at 6 months (p=0.26) and 24 months (p=0.06), no statistically significant differences were observed, but they were statistically different at 12 months (p=0.03), reflecting a greater reduction in central retinal thickness for the inner limiting membrane peeling with abrasion technique group after one year. Conclusion: Abrasion of the inner limiting membrane with a diamond-dusted membrane scraper during epiretinal membrane surgery demonstrates similar effectiveness to the standard inner limiting membrane peeling technique. At 12 months, retinal thinning was found to be more significant in inner limiting membrane peeling with abrasion technique patients in terms of central retinal thickness values. As a result, it may be argued that the inner limiting membrane abrasion technique eliminates the inner limiting membrane and related structures more effectively while inflicting less retinal damage.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Internal limiting membrane peeling prevents recurrence in vitrectomy for idiopathic epiretinal membrane
    Hashimoto, H
    Sato, T
    Suzuki, A
    Kishi, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U752 - U752
  • [22] Inverted internal limiting membrane flap technique versus complete internal limiting membrane peeling in large macular hole surgery: a comparative study
    Ramtohul, Prithvi
    Parrat, Eric
    Denis, Daniele
    Lorenzi, Umberto
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [23] Inverted internal limiting membrane flap technique versus complete internal limiting membrane peeling in large macular hole surgery: a comparative study
    Prithvi Ramtohul
    Eric Parrat
    Danièle Denis
    Umberto Lorenzi
    BMC Ophthalmology, 20
  • [24] INTERNAL LIMITING MEMBRANE-CHANGES AFTER EPIRETINAL PEELING
    LAI, S
    RATHSCHULER, F
    COLACINO, R
    ROSSI, P
    CIURLO, G
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1991, 14 (11-12): : 647 - 649
  • [25] Giant internal limiting membrane tears in eyes with a visually significant epiretinal membrane undergoing pars plana vitrectomy with internal limiting membrane peeling
    Hyde, Robert A.
    Durrani, Asad Farooq
    Johnson, Mark W.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [26] Irregular surface of the inner retina after epiretinal membrane surgery without internal limiting membrane peeling
    Gabriel, Maximilian
    Djavid, Daniel
    Innauer, Felix
    Ivastinovic, Domagoj
    Seidel, Gerald
    Mayer-Xanthaki, Christoph
    Ansari-Shahrezaei, Siamak
    Wedrich, Andreas
    Haas, Anton
    ACTA OPHTHALMOLOGICA, 2023, 101 (01) : E115 - E116
  • [27] DETRIMENTAL EFFECTS OF ACTIVE INTERNAL LIMITING MEMBRANE PEELING DURING EPIRETINAL MEMBRANE SURGERY Microperimetric Analysis
    Deltour, Jean-Baptiste
    Grimbert, Pierre
    Masse, Helene
    Lebreton, Olivier
    Weber, Michel
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (03): : 544 - 552
  • [28] Clinical Outcomes of Indocyanine Green-Assisted Peeling of the Internal Limiting Membrane in Epiretinal Membrane Surgery
    Choi, Woo Seok
    Jeong, Woo Jin
    Kwon, Yoon Hyung
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (03): : 445 - 452
  • [29] Assessment of macular function by multifocal electroretinography following epiretinal membrane surgery with internal limiting membrane peeling
    Lim, Ji Won
    Cho, Joon Hee
    Kim, Ha Kyoung
    CLINICAL OPHTHALMOLOGY, 2010, 4 : 689 - 694
  • [30] COMPARISON BETWEEN SUBJECTIVE AND OBJECTIVE INTERNAL LIMITING MEMBRANE PEELING AREA DURING EPIRETINAL MEMBRANE SURGERY
    Koehrer, Philippe
    Bron, Alain M.
    Dugas, Brice
    Isaico, Rodica
    Creuzot-Garcher, Catherine
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2014, 34 (07): : 1335 - 1340