Rapid T2*-weighted MRI using multishot EPI with retrospective motion and phase correction in the emergency department

被引:0
|
作者
Li, Zhiqiang [1 ,3 ]
Ooi, Melvyn B. [2 ]
Murchison, James A. [1 ]
Karis, John P. [1 ]
机构
[1] Barrow Neurol Inst, Dept Neuroradiol, Phoenix, AZ USA
[2] Philips Healthcare, Houston, TX USA
[3] St Josephs Hosp, Barrow Neurol Inst, Neurosci Publicat, 350 W Thomas Rd, Phoenix, AZ 85013 USA
关键词
emergency department; motion correction; multishot EPI; phase correction; T*(2)-weighted MRI; CEREBRAL MICROBLEEDS; ECHO; HEMORRHAGE; BRAIN; SENSE;
D O I
10.1002/mrm.29809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Brain MRI is increasingly used in the emergency department (ED), where T*(2)-weighted MRI is an essential tool for detecting hemorrhage and stroke. The goal of this study was to develop a rapid T*(2)-weighted MRI technique capable of correcting motion-induced artifacts, thereby simultaneously improving scan time and motion robustness for ED applications.Methods: A 2D gradient-echo (GRE)-based multishot EPI (msEPI) technique was implemented using a navigator echo for estimating motion-induced errors. Bulk rigid head motion and phase errors were retrospectively corrected using an iterative conjugate gradient approach in the reconstruction pipeline. Three volunteers and select patients were imaged at 3 T and/or 1.5 T with an approximately 1-min full-brain protocol using the proposed msEPI technique and compared to an approximately 3-min standard-of-care GRE protocol to examine its performance.Results: Data from volunteers demonstrated that in-plane motion artifacts could be effectively corrected with the proposed msEPI technique, and through-plane motion artifacts could be mitigated. Patient images were qualitatively reviewed by one radiologist without a formal statistical analysis. These results suggested the proposed technique could correct motion-induced artifacts in the clinical setting. In addition, the conspicuity of susceptibility-related lesions using the proposed msEPI technique was comparable, or improved, compared to GRE.Conclusion: A 1-min full-brain T*(2)-weighted MRI technique was developed using msEPI with a navigator echo to correct motion-induced errors. Preliminary clinical results suggest faster scans and improved motion robustness and lesion conspicuity make msEPI a competitive alternative to traditional T*(2)-weighted MRI techniques for brain studies in the ED.
引用
收藏
页码:2500 / 2509
页数:10
相关论文
共 50 条
  • [21] Reducing motion sensitivity in 3D high-resolution T2*-weighted MRI by navigator-based motion and nonlinear magnetic field correction
    Liu, Jiaen
    van Gelderen, Peter
    de Zwart, Jacco A.
    Duyn, Jeff H.
    NEUROIMAGE, 2020, 206
  • [22] High resolution T2*-weighted Magnetic Resonance Imaging at 3 Tesla using PROPELLER-EPI
    Kraemer, Martin
    Reichenbach, Juergen R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2014, 24 (02): : 164 - 173
  • [23] A theoretical framework for retrospective T2* correction to the arterial input function in quantitative myocardial perfusion MRI
    Fan, Lexiaozi
    Allen, Bradley D.
    Culver, Austin E.
    Hsu, Li-Yueh
    Hong, Kyungpyo
    Benefield, Brandon C.
    Carr, James C.
    Lee, Daniel C.
    Kim, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (02) : 1137 - 1144
  • [24] Motion correction of multi-contrast images applied to T1 and T2 quantification in cardiac MRI
    Anne Menini
    Glenn S. Slavin
    Jeffrey A. Stainsby
    Pauline Ferry
    Jacques Felblinger
    Freddy Odille
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2015, 28 : 1 - 12
  • [25] Motion correction of multi-contrast images applied to T1 and T2 quantification in cardiac MRI
    Menini, Anne
    Slavin, Glenn S.
    Stainsby, Jeffrey A.
    Ferry, Pauline
    Felblinger, Jacques
    Odille, Freddy
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2015, 28 (01) : 1 - 12
  • [26] Accuracy of MRI T2*-weighted sequences (GRE-EPI) compared to CTA for detection of anterior circulation large vessel thrombus
    Javier M. Romero
    Afonso C. P. Liberato
    Daniel Montes
    Isabelle Barnaure
    Jing Xu
    Noor Maza
    Ramon G. Gonzalez
    Emergency Radiology, 2020, 27 : 269 - 275
  • [27] Accuracy of MRI T2*-weighted sequences (GRE-EPI) compared to CTA for detection of anterior circulation large vessel thrombus
    Romero, Javier M.
    Liberato, Afonso C. P.
    Montes, Daniel
    Barnaure, Isabelle
    Xu, Jing
    Maza, Noor
    Gonzalez, Ramon G.
    EMERGENCY RADIOLOGY, 2020, 27 (03) : 269 - 275
  • [28] Human Imaging at 9.4 T Using T2*-, Phase-, and Susceptibility-Weighted Contrast
    Budde, Juliane
    Shajan, G.
    Hoffmann, Jens
    Ugurbil, Kamil
    Pohmann, Rolf
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (02) : 544 - 550
  • [29] Evaluation of liver fat in the presence of iron with MRI using T2* correction: a clinical approach
    Henninger Benjamin
    Kremser Christian
    Rauch Stefan
    Eder Robert
    Judmaier Werner
    Zoller Heinz
    Michaely Henrik
    Schocke Michael
    European Radiology, 2013, 23 : 1643 - 1649
  • [30] Evaluation of liver fat in the presence of iron with MRI using T2*correction: a clinical approach
    Benjamin, Henninger
    Christian, Kremser
    Stefan, Rauch
    Robert, Eder
    Werner, Judmaier
    Heinz, Zoller
    Henrik, Michaely
    Michael, Schocke
    EUROPEAN RADIOLOGY, 2013, 23 (06) : 1643 - 1649