A Comparison of the Corneal Thickness Following Descemet's Stripping Automated Endothelial Keratoplasty and Descemet's Membrane Endothelial Keratoplasty

被引:0
|
作者
Sunouchi, Chihiro [1 ]
Hayashi, Takahiko [1 ,2 ,7 ]
Shimizu, Toshiki [1 ]
Hara, Yusuke [1 ]
Kurita, Junki [1 ]
Kobashigawa, Hiroko [3 ]
Oyakawa, Itaru [4 ]
Ida, Yasutsugu [2 ]
Kobayashi, Akira [5 ]
Shoji, Jun [1 ,6 ]
Yamagami, Satoru [1 ]
机构
[1] Nihon Univ Med, Dept Ophthalmol, Tokyo, Japan
[2] Yokohama Minami Kyosai Hosp, Dept Ophthalmol, Kanagawa, Japan
[3] Yokosuka Chuo Eye Clin, Kanagawa, Japan
[4] Heart Life Hosp, Dept Ophthalmol, Okinawa, Japan
[5] Kanazawa Univ, Grad Sch Med Sci, Dept Ophthalmol, Ishikawa, Japan
[6] Shoji Eye Clin, Chiba, Japan
[7] Nihon Univ Med, Dept Ophthalmol, 30-1 Oyaguchikamimachi,Itabashi Ku, Tokyo 1738610, Japan
关键词
Descemet's stripping automated endothelial keratoplasty; Descemet's membrane endothelial keratoplasty; central corneal thickness; recipient corneal thickness; corneal thinning;
D O I
10.1080/02713683.2023.2203424
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo compare the central corneal thickness before and after Descemet's stripping automated endothelial keratoplasty (DSAEK) and Descemet's membrane endothelial keratoplasty (DMEK), and to evaluate the recipient corneal thickness following DSAEK.MethodsThe corneal thickness was compared between two groups of eyes following DMEK and DSAEK, performed by a single surgeon between 2015 and 2017. We evaluated the recipient corneal thickness and central corneal thickness pre- and postoperatively at 1, 3, and 6 months using anterior segment optical coherence tomography. Recipient corneal thickness was defined as the corneal thickness without graft thickness.ResultsWe included DMEK and DSAEK eyes (n = 26 each), which were similar in terms of their etiologies. Preoperatively, there was no significant difference in the central corneal thickness between the groups (DSAEK, median [interquartile range]: 721 [606.5 to 847.8] mu m; and DMEK: 690 [618 to 722.3] mu m; p = 0.30). Despite the tendency of the central corneal thickness to be significantly greater (p < .01) at 6 months following DSAEK (619.5 [607.8 to 661.3] mu m) compared with that following DMEK (497.5 [475.8 to 525.3] mu m), there was no significant difference at 6 months between the recipient corneal thickness following DSAEK (488.5 [443.8 to 515] mu m) and central corneal thickness following DMEK (p = 0.54).ConclusionsDSAEK eyes display a similar tendency of stromal thinning as DMEK eyes.
引用
收藏
页码:712 / 718
页数:7
相关论文
共 50 条
  • [41] Endothelial keratoplasty without stripping the Descemet's membrane
    Chaurasia, Sunita
    Ramappa, Muralidhar
    Murthy, Somasheila I.
    Garg, Prashant
    Sangwan, Virender S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (10) : 1473 - 1474
  • [42] Descemet's stripping automated endothelial keratoplasty and penetrating keratoplasty for Fuchs' endothelial dystrophy
    Hjortdal, Jesper
    Ehlers, Niels
    ACTA OPHTHALMOLOGICA, 2009, 87 (03) : 310 - 314
  • [43] Recipient corneal thickness and visual outcome after Descemet's stripping automated endothelial keratoplasty
    Ivarsen, Anders
    Hjortdal, Jesper
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (01) : 30 - 34
  • [44] Corneal Endothelial Cell Loss and Graft Thickness Following Descemet-Stripping Automated Endothelial Keratoplasty
    Inatomi, T.
    Adachi, H.
    Tanioka, H.
    Hieda, O.
    Kinoshita, S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [45] Descemet Membrane Endothelial Keratoplasty After Failed Descemet Stripping Without Endothelial Keratoplasty
    Rao, Rohini
    Borkar, Durga S.
    Colby, Kathryn A.
    Veldman, Peter B.
    CORNEA, 2017, 36 (07) : 763 - 766
  • [46] Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping automated endothelial keratoplasty: a meta-analysis
    Sela, Tal Corina
    Iflah, Moti
    Muhsen, Khitam
    Zahavi, Alon
    BMJ OPEN OPHTHALMOLOGY, 2023, 8 (01):
  • [47] Outcomes of Descemet membrane endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty and penetrating keratoplasty from a single centre study
    S. Heinzelmann
    D. Böhringer
    P. Eberwein
    T. Reinhard
    P. Maier
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 515 - 522
  • [48] Microthin Descemet Stripping Automated Endothelial Keratoplasty Versus Descemet Membrane Endothelial Keratoplasty: A Randomized Clinical Trial
    Matsou, Artemis
    Pujari, Rathin
    Sarwar, Hammad
    Rana, Mrinal
    Myerscough, James
    Thomson, Susan M.
    Nandakumar, Girinath
    Zhang, Jufen
    Rajan, Madhavan S.
    CORNEA, 2021, 40 (09) : 1117 - 1125
  • [49] Influence of corneal thickness on intraocular pressure measurements following Descemet's stripping automated endothelial keratoplasty (DSAEK)
    Klamann, M. K. J.
    Maier, A. -K. B.
    Gonnermann, J.
    Torun, N.
    Ruokonen, P. C.
    OPHTHALMOLOGE, 2012, 109 (11): : 1093 - 1097
  • [50] Visual outcomes following Descemet stripping automated endothelial keratoplasty for corneal endothelial dysfunction
    Guechi, Oualid
    Lhuillier, Louis
    Houmad, Naila
    Goetz, Christophe
    Ouamara, Nadia
    Perone, Jean Marc
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (05) : 513 - 519