A Comparison of the Corneal Thickness Following Descemet's Stripping Automated Endothelial Keratoplasty and Descemet's Membrane Endothelial Keratoplasty

被引:0
|
作者
Sunouchi, Chihiro [1 ]
Hayashi, Takahiko [1 ,2 ,7 ]
Shimizu, Toshiki [1 ]
Hara, Yusuke [1 ]
Kurita, Junki [1 ]
Kobashigawa, Hiroko [3 ]
Oyakawa, Itaru [4 ]
Ida, Yasutsugu [2 ]
Kobayashi, Akira [5 ]
Shoji, Jun [1 ,6 ]
Yamagami, Satoru [1 ]
机构
[1] Nihon Univ Med, Dept Ophthalmol, Tokyo, Japan
[2] Yokohama Minami Kyosai Hosp, Dept Ophthalmol, Kanagawa, Japan
[3] Yokosuka Chuo Eye Clin, Kanagawa, Japan
[4] Heart Life Hosp, Dept Ophthalmol, Okinawa, Japan
[5] Kanazawa Univ, Grad Sch Med Sci, Dept Ophthalmol, Ishikawa, Japan
[6] Shoji Eye Clin, Chiba, Japan
[7] Nihon Univ Med, Dept Ophthalmol, 30-1 Oyaguchikamimachi,Itabashi Ku, Tokyo 1738610, Japan
关键词
Descemet's stripping automated endothelial keratoplasty; Descemet's membrane endothelial keratoplasty; central corneal thickness; recipient corneal thickness; corneal thinning;
D O I
10.1080/02713683.2023.2203424
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo compare the central corneal thickness before and after Descemet's stripping automated endothelial keratoplasty (DSAEK) and Descemet's membrane endothelial keratoplasty (DMEK), and to evaluate the recipient corneal thickness following DSAEK.MethodsThe corneal thickness was compared between two groups of eyes following DMEK and DSAEK, performed by a single surgeon between 2015 and 2017. We evaluated the recipient corneal thickness and central corneal thickness pre- and postoperatively at 1, 3, and 6 months using anterior segment optical coherence tomography. Recipient corneal thickness was defined as the corneal thickness without graft thickness.ResultsWe included DMEK and DSAEK eyes (n = 26 each), which were similar in terms of their etiologies. Preoperatively, there was no significant difference in the central corneal thickness between the groups (DSAEK, median [interquartile range]: 721 [606.5 to 847.8] mu m; and DMEK: 690 [618 to 722.3] mu m; p = 0.30). Despite the tendency of the central corneal thickness to be significantly greater (p < .01) at 6 months following DSAEK (619.5 [607.8 to 661.3] mu m) compared with that following DMEK (497.5 [475.8 to 525.3] mu m), there was no significant difference at 6 months between the recipient corneal thickness following DSAEK (488.5 [443.8 to 515] mu m) and central corneal thickness following DMEK (p = 0.54).ConclusionsDSAEK eyes display a similar tendency of stromal thinning as DMEK eyes.
引用
收藏
页码:712 / 718
页数:7
相关论文
共 50 条
  • [31] Outcome of Descemet membrane endothelial keratoplasty for graft failure after Descemet stripping automated endothelial keratoplasty
    Agha, Bishr
    Shajari, Mehdi
    Slavik-Lencova, Anna
    Kohnen, Thomas
    Schmack, Ingo
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 553 - 559
  • [32] The Ongoing Debate: Descemet Membrane Endothelial Keratoplasty Versus Ultrathin Descemet Stripping Automated Endothelial Keratoplasty
    Busin, Massimo
    Yu, Angeli Christy
    OPHTHALMOLOGY, 2020, 127 (09) : 1160 - 1161
  • [33] Comparison of Visual Acuity Outcomes Between Nanothin Descemet Stripping Automated Endothelial Keratoplasty and Descemet Membrane Endothelial Keratoplasty
    Kurji, Khaliq H.
    Cheung, Albert Y.
    Eslani, Medi
    Rolfes, Erin J.
    Chachare, Deepali Y.
    Auteri, Nicholas J.
    Nordlund, Michael L.
    Holland, Edward J.
    CORNEA, 2018, 37 (10) : 1226 - 1231
  • [34] Ultrathin Descemet stripping automated endothelial keratoplasty versus Descemet membrane endothelial keratoplasty: a fellow-eye comparison
    Rita Mencucci
    Eleonora Favuzza
    Elisa Marziali
    Michela Cennamo
    Cosimo Mazzotta
    Ersilia Lucenteforte
    Gianni Virgili
    Stanislao Rizzo
    Eye and Vision, 7
  • [35] Ultrathin Descemet stripping automated endothelial keratoplasty versus Descemet membrane endothelial keratoplasty: a fellow-eye comparison
    Mencucci, Rita
    Favuzza, Eleonora
    Marziali, Elisa
    Cennamo, Michela
    Mazzotta, Cosimo
    Lucenteforte, Ersilia
    Virgili, Gianni
    Rizzo, Stanislao
    EYE AND VISION, 2020, 7 (01)
  • [36] Outcomes of Descemet Membrane Endothelial Keratoplasty in Eyes With a Previous Descemet Stripping Automated Endothelial Keratoplasty Graft
    Sorkin, Nir
    Showail, Mahmood
    Einan-Lifshitz, Adi
    Boutin, Tanguy
    Borovik, Armand
    Kreimei, Mohammad
    Rosenblatt, Amir
    Chan, Clara C.
    Rootman, David S.
    CORNEA, 2018, 37 (06) : 678 - 681
  • [37] Descemet's Stripping Automated Endothelial Keratoplasty versus Descemet's Membrane Endothelial Keratoplasty in the Fellow Eye for Fuchs Endothelial Dystrophy: A Retrospective Study
    Bhandari, Vipul
    Reddy, Jagdeesh K.
    Relekar, Kirti
    Prabhu, Vijayalakshmi
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [38] Systematic Review and Meta-Analysis of Clinical Outcomes of Descemet Membrane Endothelial Keratoplasty Versus Descemet Stripping Endothelial Keratoplasty/Descemet Stripping Automated Endothelial Keratoplasty
    Singh, Abhimanyu
    Zarei-Ghanavati, Mehran
    Avadhanam, Venkata
    Liu, Christopher
    CORNEA, 2017, 36 (11) : 1437 - 1443
  • [39] Prevention and management of complications in descemet membrane endothelial keratoplasty (DMEK) and descemet stripping automated endothelial keratoplasty (DSAEK) [Komplikationsvermeidung und -management bei "descemet membrane endothelial keratoplasty" (DMEK) und "descemet stripping automated endothelial keratoplasty" (DSAEK)]
    Cursiefen C.
    Steven P.
    Roters S.
    Heindl L.M.
    Der Ophthalmologe, 2013, 110 (7): : 614 - 621
  • [40] Descemet stripping automated endothelial keratoplasty
    Sharma, Namrata
    Maharana, Prafulla K.
    Singhi, Shipra
    Aron, Neelima
    Patil, Mukesh
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (03) : 198 - 209