Smartphone-based fluorescent sensing platforms for point-of-care ocular lactoferrin detection

被引:17
|
作者
Shi, Yuqi [1 ]
Zhang, Yihan [1 ]
Hu, Yubing [1 ]
Moreddu, Rosalia [2 ]
Fan, Zichen [1 ]
Jiang, Nan [3 ,4 ]
Yetisen, Ali K. [1 ]
机构
[1] Imperial Coll London, Dept Chem Engn, London SW7 2BU, England
[2] Ist Italiano Tecnol, Via Morego 30, I-16163 Genoa, Italy
[3] Sichuan Univ, West China Sch Basic Med Sci & Forens Med, Chengdu 610041, Peoples R China
[4] Jinfeng Lab, Chongqing 401329, Peoples R China
基金
英国工程与自然科学研究理事会;
关键词
Lactoferrin detection; Tear biomarker; Ocular analysis; Fluorescent sensor; Point-of-care diagnosis; Smartphone readout devices; HUMAN TEAR FLUID; PERFORMANCE LIQUID-CHROMATOGRAPHY; BOVINE LACTOFERRIN; INFANT FORMULA; DEVICE; QUANTIFICATION; IMMUNOASSAY; DISTANCE; ASSAY; MILK;
D O I
10.1016/j.snb.2022.133128
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lactoferrin is a critical glycoprotein that accounts for the major component in tear protein composition. Tear lactoferrin has been indicated as a potential biomarker in ocular health screening, such as dry eye disease diagnosis. Fluorescent biosensors are a desirable alternative to current diagnostic methods, due to their high selectivity and sensitivity, and rapid and cost-effective detection technologies at point-of-care (POC) platforms. Herein, fluorescent lactoferrin sensing is examined and applied on nitrocellulose membrane, capillary tube, and contact lens platforms in cooperation with a developed smartphone software for data collection and analysis. Fluorescent sensors based on trivalent terbium (TbCl3) are integrated into different platforms, including nitro-cellulose membranes, capillary tubes, and contact lenses, and tested in artificial tear fluid. A bespoke 3D printed readout device integrated with a smartphone camera was employed for image acquisition and readout. The detection range of the lactoferrin sensors could be varied from 0 to 5 mg mL-1 with a strong linear relation and yielded a limit of detection (LOD) of 0.57 mg mL-1 for lateral flow sensing, 0.12 mg mL-1 for capillary tube sensing, and 0.44 mg mL-1 for contact lens sensing. The contact lens sensor obtained the highest linear regression, while the capillary tube sensor achieved a lowest LOD. This work could pave the way towards accessible lactoferrin monitoring at POC and could induce hospitalization at the UK national health service (NHS) for future clinical trials and examinations.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] A smartphone-based quantitative point-of-care testing (POCT) system for simultaneous detection of multiple heavy metal ions
    Xu, Zhenzhen
    Liu, Zijian
    Xiao, Meng
    Jiang, Lelun
    Yi, Changqing
    Chemical Engineering Journal, 2021, 394
  • [42] Lateral flow immunoassay combined with color saturation for smartphone-based quantitative point-of-care detection of Klebsiella pneumoniae
    Pham, Thu Thao
    Huyen, Nguyen T. T.
    Tran, Lam Dai
    Truong, T. N. Lien
    ADVANCES IN NATURAL SCIENCES-NANOSCIENCE AND NANOTECHNOLOGY, 2025, 16 (01)
  • [43] Competitive activation cross amplification combined with smartphone-based quantification for point-of-care detection of single nucleotide polymorphism
    Wen, Junping
    Gou, Hongchao
    Wang, Siyuan
    Lin, Qijie
    Chen, Kaifeng
    Wu, Yuqian
    Huang, Xuehuan
    Shen, Haiyan
    Qu, Xiaoyun
    Lin, Jianhan
    Liao, Ming
    Zhang, Jianmin
    BIOSENSORS & BIOELECTRONICS, 2021, 183
  • [44] A smartphone-based quantitative point-of-care testing (POCT) system for simultaneous detection of multiple heavy metal ions
    Xu, Zhenzhen
    Liu, Zijian
    Xiao, Meng
    Jiang, Lelun
    Yi, Changqing
    CHEMICAL ENGINEERING JOURNAL, 2020, 394
  • [45] Filter paper- and smartphone-based point-of-care tests for rapid and reliable detection of artificial food colorants
    Wang, Shuangshou
    Wang, Haili
    Ding, Yuwen
    Li, Wenzhi
    Gao, Hongrui
    Ding, Zongpeng
    Lin, Peng
    Gu, Jing
    Ye, Mingfu
    Yan, Tingxuan
    Chen, Hongmei
    Ye, Jin
    MICROCHEMICAL JOURNAL, 2022, 183
  • [46] Point-of-care, multispectral, smartphone-based dermascopes for dermal lesion screening and erythema monitoring
    Uthoff, Ross D.
    Song, Bofan
    Maarouf, Melody
    Shi, Vivian
    Liang, Rongguang
    JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (06)
  • [47] A smartphone-based on-site nucleic acid testing platform at point-of-care settings
    Xu, Xiayu
    Wang, Xuemin
    Hu, Jie
    Gong, Yang
    Wang, Lin
    Zhou, Wan
    Li, XiuJun
    Xu, Feng
    ELECTROPHORESIS, 2019, 40 (06) : 914 - 921
  • [48] Point-of-Care Testing of Chloramphenicol in Food Production Using Smartphone-Based Electrochemical Detector
    Geng, Changqi
    Huang, Yaqi
    Li, Bin
    Wang, Yueyu
    Zhu, Longyi
    Xu, Yuyan
    Gao, Kejiao
    Mu, Yao
    Su, Yan
    Deng, Shengyuan
    Wan, Ying
    JOURNAL OF ANALYSIS AND TESTING, 2023, 7 (01) : 33 - 39
  • [49] A smartphone-based point-of-care quantitative urinalysis device for chronic kidney disease patients
    Akraa, Shaymaa
    Pham Tran Tam, Anh
    Shen, Haifeng
    Tang, Youhong
    Tang, Ben Zhong
    Li, Jimmy
    Walker, Sandy
    JOURNAL OF NETWORK AND COMPUTER APPLICATIONS, 2018, 115 : 59 - 69
  • [50] Point-of-Care Testing of Chloramphenicol in Food Production Using Smartphone-Based Electrochemical Detector
    Changqi Geng
    Yaqi Huang
    Bin Li
    Yueyu Wang
    Longyi Zhu
    Yuyan Xu
    Kejiao Gao
    Yao Mu
    Yan Su
    Shengyuan Deng
    Ying Wan
    JournalofAnalysisandTesting, 2023, 7 (01) : 33 - 39