Smartphone-based fluorescent sensing platforms for point-of-care ocular lactoferrin detection

被引:17
|
作者
Shi, Yuqi [1 ]
Zhang, Yihan [1 ]
Hu, Yubing [1 ]
Moreddu, Rosalia [2 ]
Fan, Zichen [1 ]
Jiang, Nan [3 ,4 ]
Yetisen, Ali K. [1 ]
机构
[1] Imperial Coll London, Dept Chem Engn, London SW7 2BU, England
[2] Ist Italiano Tecnol, Via Morego 30, I-16163 Genoa, Italy
[3] Sichuan Univ, West China Sch Basic Med Sci & Forens Med, Chengdu 610041, Peoples R China
[4] Jinfeng Lab, Chongqing 401329, Peoples R China
基金
英国工程与自然科学研究理事会;
关键词
Lactoferrin detection; Tear biomarker; Ocular analysis; Fluorescent sensor; Point-of-care diagnosis; Smartphone readout devices; HUMAN TEAR FLUID; PERFORMANCE LIQUID-CHROMATOGRAPHY; BOVINE LACTOFERRIN; INFANT FORMULA; DEVICE; QUANTIFICATION; IMMUNOASSAY; DISTANCE; ASSAY; MILK;
D O I
10.1016/j.snb.2022.133128
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lactoferrin is a critical glycoprotein that accounts for the major component in tear protein composition. Tear lactoferrin has been indicated as a potential biomarker in ocular health screening, such as dry eye disease diagnosis. Fluorescent biosensors are a desirable alternative to current diagnostic methods, due to their high selectivity and sensitivity, and rapid and cost-effective detection technologies at point-of-care (POC) platforms. Herein, fluorescent lactoferrin sensing is examined and applied on nitrocellulose membrane, capillary tube, and contact lens platforms in cooperation with a developed smartphone software for data collection and analysis. Fluorescent sensors based on trivalent terbium (TbCl3) are integrated into different platforms, including nitro-cellulose membranes, capillary tubes, and contact lenses, and tested in artificial tear fluid. A bespoke 3D printed readout device integrated with a smartphone camera was employed for image acquisition and readout. The detection range of the lactoferrin sensors could be varied from 0 to 5 mg mL-1 with a strong linear relation and yielded a limit of detection (LOD) of 0.57 mg mL-1 for lateral flow sensing, 0.12 mg mL-1 for capillary tube sensing, and 0.44 mg mL-1 for contact lens sensing. The contact lens sensor obtained the highest linear regression, while the capillary tube sensor achieved a lowest LOD. This work could pave the way towards accessible lactoferrin monitoring at POC and could induce hospitalization at the UK national health service (NHS) for future clinical trials and examinations.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Smartphone-based fluorescent lateral flow immunoassay platform for highly sensitive point-of-care detection of Zika virus nonstructural protein 1
    Rong, Zhen
    Wang, Qiong
    Sun, Nanxi
    Jia, Xiaofei
    Wang, Keli
    Xiao, Rui
    Wang, Shengqi
    ANALYTICA CHIMICA ACTA, 2019, 1055 : 140 - 147
  • [22] Hands-free smartphone-based diagnostics for simultaneous detection of Zika, Chikungunya, and Dengue at point-of-care
    Ganguli, A.
    Ornob, A.
    Yu, H.
    Damhorst, G. L.
    Chen, W.
    Sun, F.
    Bhuiya, A.
    Cunningham, B. T.
    Bashir, R.
    BIOMEDICAL MICRODEVICES, 2017, 19 (04)
  • [23] Point-of-care colorimetric detection with a smartphone
    Shen, Li
    Hagen, Joshua A.
    Papautsky, Ian
    LAB ON A CHIP, 2012, 12 (21) : 4240 - 4243
  • [24] Smartphone-Based Electrochemical Immunoassay for Point-of-Care Detection of SARS-CoV-2 Nucleocapsid Protein
    Zeng, Ruijin
    Qiu, Minghao
    Wan, Qing
    Huang, Zhisheng
    Liu, Xiaolong
    Tang, Dianping
    Knopp, Dietmar
    ANALYTICAL CHEMISTRY, 2022, 94 (43) : 15155 - 15161
  • [25] Hands-free smartphone-based diagnostics for simultaneous detection of Zika, Chikungunya, and Dengue at point-of-care
    A. Ganguli
    A. Ornob
    H. Yu
    G. L. Damhorst
    W. Chen
    F. Sun
    A. Bhuiya
    B. T. Cunningham
    R. Bashir
    Biomedical Microdevices, 2017, 19
  • [26] Smartphone-Based Point-of-Care Microfluidic Platform Fabricated with a ZnO Nanorod Template for Colorimetric Virus Detection
    Xia, Yiqiu
    Chen, Yizhu
    Tang, Yeming
    Cheng, Gong
    Yu, Xu
    He, Hongzhang
    Cao, Guohong
    Lu, Huaguang
    Liu, Zhiwen
    Zheng, Si-Yang
    ACS SENSORS, 2019, 4 (12) : 3298 - 3307
  • [27] A Smartphone-Based System for the Automated Management of Point-of-Care Test Results in Hospitals
    Jang, Dasom
    Shin, Soo-Yong
    Seo, Dong-Woo
    Joo, Segyeong
    Huh, Soo-Jin
    TELEMEDICINE AND E-HEALTH, 2015, 21 (04) : 301 - 305
  • [28] Smartphone-Based Endoscope System for Advanced Point-of-Care Diagnostics: Feasibility Study
    Bae, Jung Kweon
    Vavilin, Andrey
    You, Joon S.
    Kim, Hyeongeun
    Ryu, Seon Young
    Jang, Jeong Hun
    Jung, Woonggyu
    JMIR MHEALTH AND UHEALTH, 2017, 5 (07):
  • [29] A smartphone-based diagnostic analyzer for point-of-care milk somatic cell counting
    Sun, Xiaoyun
    Zhao, Ruiming
    Wang, Xianhua
    Wu, Yunlong
    Yang, Degang
    Wang, Jianhui
    Wu, Zhihong
    Wang, Nan
    Zhang, Juan
    Xiao, Bin
    Chen, Jiaci
    Huang, Fengchun
    Chen, Ailiang
    ANALYTICA CHIMICA ACTA, 2024, 1304
  • [30] Editorial on "An automated smartphone-based diagnostic assay for point-of-care semen analysis"
    Vij, Sarah Coleman
    Agarwal, Ashok
    ANNALS OF TRANSLATIONAL MEDICINE, 2017, 5 (24)