Estimation of Effective Dose in Monte Carlo Simulation Method for CT Coronary Angiography Patients

被引:0
|
作者
Sarma, Arnabjyoti Deva [1 ]
Singha, Mrinal Kanti [1 ,2 ,3 ]
Sharma, Jibon [2 ,3 ]
Kashyap, Manash Pratim [4 ]
机构
[1] Assam downtown Univ, Dept Radiol, Gauhati, Assam, India
[2] Down Town Hosp, Gauhati, Assam, India
[3] Gauhati Med Coll, State Canc Inst, Gauhati, Assam, India
[4] Assam Down Town Univ, Dept Stat, Gauhati, Assam, India
关键词
Radiation; Computed Tomography; Effective Dose; Angiography; Monte Carlo Simulation; COMPUTED-TOMOGRAPHY EXAMINATIONS; DIAGNOSTIC REFERENCE LEVELS; MULTISLICE;
D O I
10.22376/ijlpr.2023.13.2.L194-L201
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Computed tomography (CT) scans of Coronary Angiography have significantly aided in the diagnosis of disorders of the coronary artery. In contrast to other radiological examinations, the patient's radiation exposure is notably higher. This study aimed to optimize the radiation dose and estimate the adequate amount in computed tomography (CT) for coronary angiography. A total of 380 patients were referred to the Primus Diagnostic Centre and Heath City Hospital, Guwahati Assam, during the study with coronary artery disturbances. Data on the technical parameters used in CT procedures were taken in 2022. The aim and study's objective was Organ and surface dose to specific radiosensitive organs (Chest) estimation using software imPACT 1.0.4 from National Radiological Protection Board (NRPB) SR250 Monte Carlo dataset. The study population (n = 380) comprised 190 men and 190 women with an average age of 29 to 75 years. The Mean +/- SD of BMI and ED are 22.42 +/- 1.06 and 21.57 +/- 4.27 respectively. The mean DLP is 854.67, and the mean ED is 21.57. The effective doses for males (13-27) mSv were in females (13-29) mSv. This study was a pioneer in presenting actual amounts of CT examinations in Assam because other countries have already started with more advanced CT procedures, such as dosages for paediatrics, coronary angiography and CT fluoroscopy. With this study, there may be more opportunities to create complex new studies or enhance the data from related studies that may be done in future work. The high precision with minimum risk, the current study can be considered as the need of the hour.
引用
收藏
页码:L194 / L201
页数:8
相关论文
共 50 条
  • [41] Validation of a Monte Carlo simulation for dose assessment in dental cone beam CT examinations
    Morant, J. J.
    Salvado, M.
    Casanovas, R.
    Hernandez-Giron, I.
    Velasco, E.
    Calzado, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (03): : 200 - 209
  • [42] Monte Carlo Simulation and Dose Calculation of Chest CT Scan with Tube Current Modulation
    Gao, Y.
    Ding, A.
    Zhang, D.
    Liu, B.
    Caracappa, P.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [43] VALIDATION OF A NOVEL METHOD FOR CARDIAC OUTPUT ESTIMATION BY CT CORONARY ANGIOGRAPHY
    Mehta, Hetal H.
    Sanai, Reza
    Dusaj, Raman
    Lewis, Jannet F.
    Zeman, Robert
    Choi, Brian G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E872 - E872
  • [44] Hybrid Monte Carlo CT Simulation on GPU
    Jakab, Gabor
    Szirmay-Kalos, Laszlo
    LARGE-SCALE SCIENTIFIC COMPUTING, LSSC 2013, 2014, 8353 : 161 - 169
  • [45] Monte Carlo simulation of CT guided radiotherapy
    Mechalakos, J
    Mageras, GS
    Lovelock, DM
    Hollister, T
    Katz, M
    Zelefsky, M
    Lee, H
    Lutz, W
    Ling, CC
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1672 - 1675
  • [46] Estimation of absorbed gamma dose rate from granite by Monte Carlo simulation approach
    Knezevic, J.
    Kuzmanovic, P.
    Mrdja, D.
    Todorovic, N.
    Bikit, I
    Hansman, J.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (02) : 596 - 611
  • [47] Monte Carlo simulation for the estimation of the glandular breast dose for a digital breast tomosynthesis system
    Rodrigues, Leonardo
    Goncalves Magalhaes, Luis Alexandre
    Braz, Delson
    RADIATION PROTECTION DOSIMETRY, 2015, 167 (04) : 576 - 583
  • [48] Photon and Neutron Dose Estimation Using Monte Carlo Simulation in TrueBeam's Room
    Quoc, Soai Dang
    Fujibuchi, Toshioh
    Arakawa, Hiroyuki
    Hamada, Keisuke
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 473 - 479
  • [49] Marked Reduction of Effective Radiation Dose in Patients Undergoing CT Coronary Angiography using Prospective ECG Gating
    Freeman, Anthony
    Learner, Ruth
    Eggleton, Simon
    Lambros, John
    Friedman, Daniel
    HEART LUNG AND CIRCULATION, 2011, 20 (08): : 512 - 516
  • [50] A Real-Time Monte-Carlo Simulation Technique for Dose and Scatter Estimation in Virtual Clinical Trials for CT Imaging
    Sharma, S.
    Abadi, E.
    Segars, P.
    Kapadia, A.
    Samei, E.
    MEDICAL PHYSICS, 2018, 45 (06) : E689 - E689