Estimation of Effective Dose in Monte Carlo Simulation Method for CT Coronary Angiography Patients

被引:0
|
作者
Sarma, Arnabjyoti Deva [1 ]
Singha, Mrinal Kanti [1 ,2 ,3 ]
Sharma, Jibon [2 ,3 ]
Kashyap, Manash Pratim [4 ]
机构
[1] Assam downtown Univ, Dept Radiol, Gauhati, Assam, India
[2] Down Town Hosp, Gauhati, Assam, India
[3] Gauhati Med Coll, State Canc Inst, Gauhati, Assam, India
[4] Assam Down Town Univ, Dept Stat, Gauhati, Assam, India
关键词
Radiation; Computed Tomography; Effective Dose; Angiography; Monte Carlo Simulation; COMPUTED-TOMOGRAPHY EXAMINATIONS; DIAGNOSTIC REFERENCE LEVELS; MULTISLICE;
D O I
10.22376/ijlpr.2023.13.2.L194-L201
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Computed tomography (CT) scans of Coronary Angiography have significantly aided in the diagnosis of disorders of the coronary artery. In contrast to other radiological examinations, the patient's radiation exposure is notably higher. This study aimed to optimize the radiation dose and estimate the adequate amount in computed tomography (CT) for coronary angiography. A total of 380 patients were referred to the Primus Diagnostic Centre and Heath City Hospital, Guwahati Assam, during the study with coronary artery disturbances. Data on the technical parameters used in CT procedures were taken in 2022. The aim and study's objective was Organ and surface dose to specific radiosensitive organs (Chest) estimation using software imPACT 1.0.4 from National Radiological Protection Board (NRPB) SR250 Monte Carlo dataset. The study population (n = 380) comprised 190 men and 190 women with an average age of 29 to 75 years. The Mean +/- SD of BMI and ED are 22.42 +/- 1.06 and 21.57 +/- 4.27 respectively. The mean DLP is 854.67, and the mean ED is 21.57. The effective doses for males (13-27) mSv were in females (13-29) mSv. This study was a pioneer in presenting actual amounts of CT examinations in Assam because other countries have already started with more advanced CT procedures, such as dosages for paediatrics, coronary angiography and CT fluoroscopy. With this study, there may be more opportunities to create complex new studies or enhance the data from related studies that may be done in future work. The high precision with minimum risk, the current study can be considered as the need of the hour.
引用
收藏
页码:L194 / L201
页数:8
相关论文
共 50 条
  • [31] Estimation of Characteristics for Dose Distribution in Polymer Gel by Means of Monte Carlo Simulation
    Park, M.
    Bong, J.
    Kwon, S.
    Park, S.
    Kim, K.
    Ji, Y.
    Shin, D.
    Jung, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [32] Basic Study on the Estimation of Medical Exposure Dose Using Monte Carlo Simulation
    Yamaguchi, Yoichi
    Sasaki, Takashi
    Onishi, Seiki
    Baba, Mamoru
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 191 - 193
  • [33] Combined Organ Dose for Digital Subtraction Angiography and Computed Tomography Using Monte Carlo Simulation
    Sakabe, D.
    Ohno, T.
    Araki, F.
    Hashida, M.
    Funama, Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3777 - 3777
  • [34] MONTE-CARLO ESTIMATION OF DOSE AT A POINT
    WILLIAMSON, JF
    CHANG, HM
    MEDICAL PHYSICS, 1985, 12 (04) : 516 - 516
  • [35] Patient-specific Effective Dose Estimation from Dose-Length Product in Lung Computed Tomography Using Monte Carlo Simulation
    Fallahmohammadi, Gholamreza
    Nodeh, Zeinab Kordzini
    Mahdavi, Mohammad
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2024, 14 (04):
  • [36] Evaluation of effective dose with chest digital tomosynthesis system using Monte Carlo simulation
    Kim, Dohyeon
    Jo, Byungdu
    Lee, Youngjin
    Park, Su-Jin
    Lee, Dong-Hoon
    Kim, Hee-Joung
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [37] Monte Carlo simulation of dose distribution of radiotherapy
    Liu, YM
    Xue, DY
    Xu, XH
    Chen, Z
    System Simulation and Scientific Computing, Vols 1 and 2, Proceedings, 2005, : 422 - 426
  • [38] The Monte Carlo simulation of the absorbed dose in quartz
    Chen, Shaowen
    Liu, Xiaowei
    Zhang, Chunxiang
    Tang, Qiang
    RADIATION MEASUREMENTS, 2009, 44 (5-6) : 626 - 628
  • [39] Improvement and Benchmarking of the new shutdown dose estimation method by Monte Carlo code
    Petrizzi, L
    Iida, H
    Valenza, D
    Batistoni, P
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 865 - 870
  • [40] Monte Carlo CT Dose Calculation: A Comparison Between Experiment and Simulation Using ARCHER-CT
    Liu, T.
    Du, X.
    Su, L.
    Gao, Y.
    Ji, W.
    Zhang, D.
    Shi, J.
    Liu, B.
    Kalra, M.
    Xu, X.