Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study

被引:10
|
作者
Wu, Jian [1 ,2 ]
Du, Yifan [1 ]
Lin, Caixia [1 ]
Zhu, Yingting [3 ]
Chen, Wei [2 ]
Pan, Qing [4 ,5 ]
Zhuo, Yehong [3 ]
Wang, Ningli [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Eye Ctr,Beijing Inst Ophthalmol, Beijing, Peoples R China
[2] Stanford Univ, Sch Med, Dept Ophthalmol, Palo Alto, CA 94304 USA
[3] Sun Yat Sen Univ, State Key Lab Ophthalmol, Zhongshan Ophthalm Ctr, Guangzhou, Peoples R China
[4] Sichuan Univ, West China Sch Publ Hlth, Dept Epidemiol & Biostat, Chengdu, Sichuan, Peoples R China
[5] Sichuan Univ, West China Hosp 4, Chengdu, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
retina; epidemiology; optic nerve; OPTICAL COHERENCE TOMOGRAPHY; SYSTEMIC PARAMETERS; GLAUCOMA; AGE; DETERMINANTS; ASSOCIATION; CHILDREN; CHINESE; NEURODEGENERATION; CLASSIFICATION;
D O I
10.1136/bjophthalmol-2021-320618
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To examine the normative profile of retinal nerve fibre layer (RNFL) thickness and ocular parameters based on spectral-domain optical coherence tomography (SD-OCT) and its associations with related parameters among the Chinese population. Methods This population-based cohort Handan Eye Study (HES) recruited participants aged >= 30 years. All subjects underwent a standardised ophthalmic examination. Peripapillary RNFL thickness was obtained using SD-OCT. Mixed linear models were adopted to evaluate the correlation of RNFL thickness with ocular parameters as well as systemic factors. R V.3.6.1 software was used for statistical analysis. Results 3509 subjects (7024 eyes) with the average age of 55.54 +/- 10.37 were collected in this analysis. Overall mean RNFL thickness measured was 113.46 +/- 10.90 mu m, and the thickest quadrant of parapapillary RNFL was the inferior quadrant, followed by the superior quadrant, the nasal quadrant and the temporal quadrant. In the multivariate linear regression model, thinner RNFL thickness was remarkable association with male (p<0.001), older age (p<0.001), increased body mass index (>30, p=0.018), absence of diabetes (p=0.009), history of cataract surgery (p=0.001), higher intraocular pressure (p=0.007), lower spherical equivalent (p<0.001) and increased axial length (p=0.048). Conclusions In non-glaucoma individuals, this difference of RNFL thickness in Chinese population should be noted in making disease diagnoses. Meanwhile, multiple ocular and systemic factors are closely related to the thickness of RNFL. Our findings further emphasise the need to demonstrate ethnic differences in RNFL thickness and the specificity of associated ocular and systemic factors, as well as to develop better normative databases worldwide.
引用
收藏
页码:1156 / 1164
页数:9
相关论文
共 50 条
  • [1] Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study of French elderly subjects: the Alienor study
    Rougier, Marie-Benedicte
    Korobelnik, Jean-Francois
    Malet, Florence
    Schweitzer, Cedric
    Delyfer, Marie-Noelle
    Dartigues, Jean-Francois
    Delcourt, Cecile
    Helmer, Catherine
    ACTA OPHTHALMOLOGICA, 2015, 93 (06) : 539 - 545
  • [2] Effect of refractive errors/axial length on peripapillary retinal nerve fibre layer thickness (RNFL) measured by Topcon SD-OCT
    Kausar, Ayisha
    Akhtar, Nadia
    Afzal, Farooq
    Ali, Khalid
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2018, 68 (07) : 1054 - 1059
  • [3] German Diabetes Study - Baseline data of retinal layer thickness measured by SD-OCT in early diabetes mellitus
    Schroeder, Katharina
    Szendroedi, Julia
    Benthin, Anna
    Gontscharuk, Veronika
    Ackermann, Philipp
    Voelker, Magdalena
    Steingrube, Nadine
    Nowotny, Bettina
    Ziegler, Dan
    Muessig, Karsten
    Geerling, Gerd
    Kuss, Oliver
    Roden, Michael
    Guthoff, Rainer
    ACTA OPHTHALMOLOGICA, 2019, 97 (02) : E303 - E307
  • [4] Comparing retinal nerve fiber layer thickness between SD-OCT and AO-OCT
    King, Brett
    Swanson, William H.
    Kurokawa, Kazuhiro
    Miller, Donald Thomas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [5] Serum vitamins and retinal nerve fiber layer changes on SD-OCT: the Alienor study
    Merle, Benedicte Mj
    Rougier, Marie-Benedicte
    Feart, Catherine
    Le Goff, Melanie
    Gayraud, Laure
    Delyfer, Marie-Noelle
    Schweitzer, Cedric
    Delcourt, Cecile
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [6] Peripapillary retinal nerve fibre layer thickness measurement with SD-OCT in normal and glaucomatous eyes:distribution and correlation with age
    George Kampougeris
    Dimitrios Spyropoulos
    Adrianna Mitropoulou
    Aggeliki Zografou
    Pericles Kosmides
    International Journal of Ophthalmology, 2013, (05) : 662 - 665
  • [7] Peripapillary retinal nerve fibre layer thickness measurement with SD-OCT in normal and glaucomatous eyes: distribution and correlation with age
    Kampougeris, George
    Spyropoulos, Dimitrios
    Mitropoulou, Adrianna
    Zografou, Aggeliki
    Kosmides, Pericles
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (05) : 662 - 665
  • [8] Association of retinal fibre layer thickness with cognition in a population-based study
    Rauscher, Franziska G.
    Girbardt, Johanna
    Luck, Tobias
    Kynast, Jana
    Rodriguez, Francisca S.
    Witte, A. Veronica
    Wang, Mengyu
    Engel, Christoph
    Loeffler, Markus
    Villringer, Arno
    Riedel-Heller, Steffi G.
    Schroeter, Matthias L.
    Elze, Tobias
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [9] Retinal thickness in a diabetic population measured with iVue SD-OCT compared to iVue Normative Database
    Cuadros, Jorge
    Zhou, Qienyuan
    Litvin, Taras V.
    Ozawa, Glen Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [10] Retinal layer thickness measurement using automated retinal segmentation with SD-OCT
    Soubrane, Gisele
    Aknin, Isabelle
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)