Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study

被引:10
|
作者
Wu, Jian [1 ,2 ]
Du, Yifan [1 ]
Lin, Caixia [1 ]
Zhu, Yingting [3 ]
Chen, Wei [2 ]
Pan, Qing [4 ,5 ]
Zhuo, Yehong [3 ]
Wang, Ningli [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Eye Ctr,Beijing Inst Ophthalmol, Beijing, Peoples R China
[2] Stanford Univ, Sch Med, Dept Ophthalmol, Palo Alto, CA 94304 USA
[3] Sun Yat Sen Univ, State Key Lab Ophthalmol, Zhongshan Ophthalm Ctr, Guangzhou, Peoples R China
[4] Sichuan Univ, West China Sch Publ Hlth, Dept Epidemiol & Biostat, Chengdu, Sichuan, Peoples R China
[5] Sichuan Univ, West China Hosp 4, Chengdu, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
retina; epidemiology; optic nerve; OPTICAL COHERENCE TOMOGRAPHY; SYSTEMIC PARAMETERS; GLAUCOMA; AGE; DETERMINANTS; ASSOCIATION; CHILDREN; CHINESE; NEURODEGENERATION; CLASSIFICATION;
D O I
10.1136/bjophthalmol-2021-320618
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To examine the normative profile of retinal nerve fibre layer (RNFL) thickness and ocular parameters based on spectral-domain optical coherence tomography (SD-OCT) and its associations with related parameters among the Chinese population. Methods This population-based cohort Handan Eye Study (HES) recruited participants aged >= 30 years. All subjects underwent a standardised ophthalmic examination. Peripapillary RNFL thickness was obtained using SD-OCT. Mixed linear models were adopted to evaluate the correlation of RNFL thickness with ocular parameters as well as systemic factors. R V.3.6.1 software was used for statistical analysis. Results 3509 subjects (7024 eyes) with the average age of 55.54 +/- 10.37 were collected in this analysis. Overall mean RNFL thickness measured was 113.46 +/- 10.90 mu m, and the thickest quadrant of parapapillary RNFL was the inferior quadrant, followed by the superior quadrant, the nasal quadrant and the temporal quadrant. In the multivariate linear regression model, thinner RNFL thickness was remarkable association with male (p<0.001), older age (p<0.001), increased body mass index (>30, p=0.018), absence of diabetes (p=0.009), history of cataract surgery (p=0.001), higher intraocular pressure (p=0.007), lower spherical equivalent (p<0.001) and increased axial length (p=0.048). Conclusions In non-glaucoma individuals, this difference of RNFL thickness in Chinese population should be noted in making disease diagnoses. Meanwhile, multiple ocular and systemic factors are closely related to the thickness of RNFL. Our findings further emphasise the need to demonstrate ethnic differences in RNFL thickness and the specificity of associated ocular and systemic factors, as well as to develop better normative databases worldwide.
引用
收藏
页码:1156 / 1164
页数:9
相关论文
共 50 条
  • [21] The African Descent and Glaucoma Evaluation Study (ADAGES): Racial differences in rate of change of SD-OCT measured minimum rim width and retinal nerve fiber layer thickness
    Bowd, Christopher
    Zangwill, Linda M.
    Girkin, Christopher A.
    Liebmann, Jeffrey M.
    Weinreb, Robert N.
    Belghith, Akram
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [22] Comparative data on SD-OCT for the retinal nerve fiber layer and retinal macular thickness in a large cohort with Marfan syndrome
    Xu, WanWan
    Kurup, Sudhi P.
    Fawzi, Amani A.
    Durbin, Mary K.
    Maumenee, Irene H.
    Mets, Marilyn B.
    OPHTHALMIC GENETICS, 2017, 38 (01) : 34 - 38
  • [23] Reading cognition from the eyes: association of retinal nerve fibre layer thickness with cognitive performance in a population-based study
    Girbardt, Johanna
    Luck, Tobias
    Kynast, Jana
    Rodriguez, Francisca S.
    Wicklein, Barbara
    Wirkner, Kerstin
    Engel, Christoph
    Girbardt, Christian
    Wang, Mengyu
    Polyakova, Maryna
    Witte, A. Veronica
    Loeffler, Markus
    Villringer, Arno
    Riedel-Heller, Steffi G.
    Schroeter, Matthias L.
    Elze, Tobias
    Rauscher, Franziska G.
    BRAIN COMMUNICATIONS, 2021, 3 (04)
  • [24] A STUDY OF RETINAL NERVE FIBRE LAYER THICKNESS IN MYOPIA
    Thomas, Varsha
    Joseph, Liby
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (28): : 2264 - 2269
  • [25] Accommodation induced variations of ocular axial length and retinal thickness measured with SD-OCT
    Zhou, Chuanqing
    Fan, Shanhui
    Chen, Zhe
    Chai, Xinyu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [26] Correction to: Relationship between changes in retinal nerve fiber layer thickness measured by SD-OCT and changes in visual field parameters in birdshot chorioretinopathy
    Aurélia Gave
    Lucile Cotella
    José Labarere
    Florent Aptel
    Christophe Chiquet
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 2393 - 2393
  • [27] Retinal nerve fiber layer thickness in children measured with OCT
    Salchow, DJ
    Chiang, MF
    Tsai, J
    Langton, K
    Al-Aswad, LA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [28] Relationship between the Peripapillary Choroidal Thickness and Retinal Nerve Fiber Layer Thickness: A Population-based Study
    Gupta, Preeti
    Tian, Jing
    Marziliano, Pina
    Cheung, Carol Yim-Lui
    Mani, Baskaran
    Lamoureux, Ecosse Luc
    Cheung, Gemmy
    Aung, Tin
    Wong, Tien Yin
    Cheng, Ching-Yu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [29] Automated segmentation of nine retinal layers with layer thickness information on SD-OCT images
    Liu, Xiaoming
    Wang, Jia
    Yang, Zhou
    Hu, Wei
    EIGHTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2016), 2016, 10033
  • [30] Retinal nerve fibre layer thickness measured by Spectralis spectral-domain optical coherence tomography: The Beijing Eye Study
    Zhao, Liang
    Wang, Yaxing
    Chen, Chang X.
    Xu, Liang
    Jonas, Jost B.
    ACTA OPHTHALMOLOGICA, 2014, 92 (01) : E35 - E41