Effect of refractive errors/axial length on peripapillary retinal nerve fibre layer thickness (RNFL) measured by Topcon SD-OCT

被引:0
|
作者
Kausar, Ayisha [1 ]
Akhtar, Nadia [3 ]
Afzal, Farooq [2 ]
Ali, Khalid [1 ]
机构
[1] Shifa Coll Med, Islamabad, Pakistan
[2] Shifa Int Hosp, Islamabad, Pakistan
[3] Fed Gen Hosp, Fed Med & Dent Coll, Islamabad, Pakistan
关键词
Optical coherence tomography; Refractive errors; Axial length; Glaucoma; Retinal ganglion cells; OPTICAL COHERENCE TOMOGRAPHY; CIRRUS-HD-OCT; AXIAL LENGTH; STRATUS OCT; GLAUCOMA; RTVUE; SIZE; CHILDREN; FUNDUS; MYOPIA;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To evaluate the effect of refractive error and axial length on peripapillary retinal nerve fibre layer thickness in myopic, hypermetropic and emmetropic eyes by Topcon spectral domain optical coherence tomography. Methods: This cross-sectional study was conducted at the ophthalmology clinic of Shifa Foundation Falahee Clinic, Islamabad, Pakistan, from January to December 2016, and comprised eye patients including emmetropes, hypermetropes and myopes. All participants underwent detailed ophthalmic examination including axial lengths measurements, auto refraction andretinal nerve fibre layer thickness analysis. Retinal nerve fibre layer thickness was obtained from the peripapillary quadrants: temporal, superior, nasal and inferior and 12 sub-quadrants using Topcon spectral domain optical coherence tomography. Pearson correlation coefficients (r) were calculated to evaluate relationships between the retinal nerve fibre layer thickness and axial length before and after adjustment for ocular magnification by using Littmann's formula. Results: Of the total 93 eyes of as many patients, 46(49.5%) were right eyes and 47(51.5%) left eyes. There were 35(37.6%) myopes, 29(31.2%) hypermetropes and 29(31.2%) emmetropes. Mean age was 30.45 +/- 7.86years. Mean axial length was 23.40 +/- 1.25mm. Mean retinal nerve fibre layer thickness after correction of magnification effect was 100.59 +/- 9.25 mu m. Correlation analyses showed that the average retinal nerve fibre layer thickness and mean thickness of major superior and nasal quadrants and also in nasal, upper nasal, superonasal, inferior and inferonasal sub-quadrants had negative correlation with axial length. However, correction of the magnification effect by applying Littmann's formula eliminated the relationship between the two. Conclusions: Retinal nerve fibre layer thickness measurements were found to vary with refractive status and axial length of the eye. Ocular magnification significantly affected the retinal nerve fibre layer thickness, and it should be considered in diagnosing glaucoma.
引用
收藏
页码:1054 / 1059
页数:6
相关论文
共 50 条
  • [1] Peripapillary Retinal Nerve Fiber Layer (RNFL) Thickness Measurements by Topcon SD-OCT in Myopic Patients
    Akhtar, Nadia
    Kausar, Ayisha
    Afzal, Farooq
    Ali, Syed Khalid
    Hamid, Nida
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2018, 28 (01): : 26 - 30
  • [2] Effect of Refractive Status and Axial Length on Peripapillary Retinal Nerve Fibre Layer Thickness: An Analysis Using 3D OCT
    Sowmya, V.
    Venkataramanan, V. R.
    Prasad, Vishnu
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (09) : NC1 - NC4
  • [3] Effect of Weiss ring on peripapillary retinal nerve fiber layer thickness measurements using SD-OCT
    Kim, Min-Su
    Nam, Ki-Yup
    Hwang, Young Hoon
    Lee, Min-Woo
    Lee, Woo-Hyuk
    Lim, Hyung-Bin
    Kim, Jung-Yeul
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [4] Effect of Weiss ring on peripapillary retinal nerve fiber layer thickness measurements using SD-OCT
    Min-Su Kim
    Ki-Yup Nam
    Young Hoon Hwang
    Min-Woo Lee
    Woo-Hyuk Lee
    Hyung-Bin Lim
    Jung-Yeul Kim
    Scientific Reports, 12
  • [5] Peripapillary retinal nerve fibre layer thickness measurement with SD-OCT in normal and glaucomatous eyes:distribution and correlation with age
    George Kampougeris
    Dimitrios Spyropoulos
    Adrianna Mitropoulou
    Aggeliki Zografou
    Pericles Kosmides
    International Journal of Ophthalmology, 2013, (05) : 662 - 665
  • [6] Peripapillary retinal nerve fibre layer thickness measurement with SD-OCT in normal and glaucomatous eyes: distribution and correlation with age
    Kampougeris, George
    Spyropoulos, Dimitrios
    Mitropoulou, Adrianna
    Zografou, Aggeliki
    Kosmides, Pericles
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (05) : 662 - 665
  • [7] Accommodation induced variations of ocular axial length and retinal thickness measured with SD-OCT
    Zhou, Chuanqing
    Fan, Shanhui
    Chen, Zhe
    Chai, Xinyu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [8] Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study
    Wu, Jian
    Du, Yifan
    Lin, Caixia
    Zhu, Yingting
    Chen, Wei
    Pan, Qing
    Zhuo, Yehong
    Wang, Ningli
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2023, 107 (08) : 1156 - 1164
  • [9] Effect of Axial Length on the Difference Between SS-OCT and SD-OCT Retinal Nerve Fiber Layer Thickness Measurements in Highly Myopic Eyes
    Loh, Isabella
    Chong, Rachel S.
    Tan, Bingyao
    Yu, Daryle Jason
    Wong, Qiu Ying
    Dan, Yee Shan
    Wong, Chee Wai
    Hoang, Quan V.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [10] Adjustment of the Retinal Angle in SD-OCT of Glaucomatous Eyes Provides Better Intervisit Reproducibility of Peripapillary RNFL Thickness
    Lee, Kyungmoo
    Sonka, Milan
    Kwon, Young H.
    Garvin, Mona K.
    Abramoff, Michael D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) : 4808 - 4812