Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review

被引:9
|
作者
Costa, J. A. [1 ]
Mendes, J. M. [2 ]
Salazar, F. [2 ]
Pacheco, J. J. [2 ]
Rompante, P. [2 ]
Camara, M. I. [1 ]
机构
[1] CESPU, Univ Inst Hlth Sci IUCS, Med & Oral Surg Dept, P-4585116 Gandra, Portugal
[2] CESPU, Univ Inst Hlth Sci IUCS, UNIPRO Oral Pathol & Rehabil Res Unit, P-4585116 Gandra, Portugal
关键词
CBCT; Cone-beam computed tomography; Dental implant; Peri-implant; Bone loss; PERIAPICAL RADIOGRAPHY; BUCCAL BONE; ACCURACY;
D O I
10.1007/s11282-023-00683-w
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The objective of this work was to perform an integrative review of the inspection of peri-implant bone defects using cone beam computed tomography (CBCT). An electronic search was performed in the PubMed database using the following scientific terms: CBCT or Cone Beam computed tomography; dental implant; peri-implant; bone loss; defects. The survey identified 267 studies, of which 18 were considered relevant to this study. These studies provided important data taking into account the accuracy of cone beam computed tomography in the detection and measurement of peri-implant bone defects such as fenestrations, dehiscence and intraosseous circumferential defects. The effectiveness of CBCT in aiding in geometric bone calculations and in the diagnosis of peri-implant defects was influenced by factors such as artefacts, defect size, bone wall thickness, implant material, adjustment of acquisition parameters and observer experience. A not insignificant number of studies compared intraoral radiography to CBCT in the detection of peri-implant bone loss. CBCT was clearly superior to intraoral radiography in the detection of all peri-implant bone defects, except for defects located in the interproximal zone. In general, studies have shown that peri-implant bone measurements adjacent to the implant surface can be correctly determined, as well as the diagnosis of peri-implant bone defects with an average discrepancy of less than 1 mm from the actual measurement of the defect.
引用
收藏
页码:455 / 466
页数:12
相关论文
共 50 条
  • [31] Higher Resolution in Cone Beam Computed Tomography Is Accompanied by Improved Bone Detection in Peri-implant Bone Despite Metal Artifact Presence
    Kerkfeld, Valentin
    Meyer, Ulrich
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1331 - 1338
  • [32] Quantitative measurement of peri-implant bone defects using optical coherence tomography
    Kim, Sulhee
    Kang, Se-Ryong
    Park, Hee-Jung
    Kim, Bome
    Kim, Tae-Il
    Yi, Won-Jin
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2018, 48 (02): : 84 - 91
  • [33] Comprehensive peri-implant tissue evaluation with ultrasonography and cone-beam computed tomography: A pilot study
    Siqueira, Rafael
    Sinjab, Khaled
    Pan, Ying-Chun
    Soki, Fabiana
    Chan, Hsun-Liang
    Kripfgans, Oliver
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (07) : 777 - 785
  • [34] Effectiveness of Periapical Radiography Versus Cone Beam Computed Tomography with Different Kilovoltage Settings in the Detection of Chemically Created Peri-implant Bone Defects: An In Vitro Study
    Pinheiro, Lucas Rodrigues
    Scarfe, William C.
    de Oliveira Sales, Marcelo Augusto
    Gaia, Bruno Felipe
    Gonzalez Cortes, Arthur Rodriguez
    Paraiso Cavalcanti, Marcelo Gusmao
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 741 - 750
  • [35] Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study
    Zhang, Chu-Nan
    Zhu, Yu
    Fan, Lin-Feng
    Zhang, Xiao
    Jiang, Yin-Hua
    Gu, Ying-Xin
    JOURNAL OF DENTAL SCIENCES, 2021, 16 (03) : 948 - 956
  • [36] Influence of Peri-implant Artifacts on Bone Morphometric Analysis with Micro-computed Tomography
    Song, Jin Wook
    Cha, Jung Yul
    Bechtold, Till Edward
    Park, Young Chel
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 519 - 525
  • [37] Measurement of Peri-Implant Bone Width with and without Metal Artifact Reduction Algorithm Using Two Cone-Beam Computed Tomography Software Programs
    Hedayatipanah, Morad
    Salemi, Fatemeh
    Kamyari, Naser
    Yalpanian, Ashkan
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2021, 21
  • [38] Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
    Magat, Guldane
    Oncu, Elif
    Ozcan, Sevgi
    Orhan, Kaan
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2022, 48 (01) : 41 - 49
  • [39] Evaluation of peri-implant buccal bone by computed tomography: an experimental study
    Gonzalez-Martin, Oscar
    Oteo, Carlos
    Ortega, Ricardo
    Alandez, Javier
    Sanz, Mariano
    Veltri, Mario
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (08) : 950 - 955
  • [40] Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study
    Silveira-Neto, Nicolau
    Flores, Mateus Ericson
    De Carli, Joao Paulo
    Costa, Max Doria
    Matos, Felipe de Souza
    Paranhos, Luiz Renato
    Sandini Linden, Maria Salete
    CLINICS, 2017, 72 (11) : 708 - 713