Simultaneous Determination of Cortisol and 6β-Hydroxycortisol in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry

被引:0
|
作者
Sun, Lu-Ning [1 ,2 ]
Shen, Ye [1 ]
Yang, Yu-Qing [1 ]
Chen, Xiang-Long [1 ]
Huang, Feng-Ru [1 ]
Wang, Dun-Jian [1 ]
Zhang, Ye [3 ]
Wang, Da-Wei [4 ]
Wang, Yong-Qing [1 ,2 ]
机构
[1] Nanjing Med Univ, Affiliated Hosp 1, Res Div Clin Pharmacol, Nanjing 210029, Peoples R China
[2] Nanjing Med Univ, Sch Pharm, Nanjing 210029, Peoples R China
[3] Nanjing Jinling Hosp, Dept Pharm, Nanjing 211166, Peoples R China
[4] Nanjing Univ Chinese Med, Affiliated Hosp Integrated Tradit Chinese & Weste, Nanjing 210028, Peoples R China
关键词
ERYTHROMYCIN BREATH TEST; CYP3A ACTIVITY; MIDAZOLAM MICRODOSE; ORAL MIDAZOLAM; MARKERS; INHIBITION; CLEARANCE; ENZYMES; PROBES; URINE;
D O I
10.1093/chromsci/bmac038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The feasibility of taking the ratio of 6 beta-hydroxycortisol (6 beta-OHCOR) to cortisol (COR) in plasma as a biomarker to reflect CYP3A4 activity needs to be verified, but the low concentration of 6 beta-OHCOR which is an endogenous substance in plasma presents a challenge for determination. In this study, a Liquid chromatography with tandem mass spectrometry (LC-MS/MS) method was established to simultaneously quantify the COR and 6 beta-OHCOR in plasma with COR-d4 and 6 beta-OHCOR-d4 as internal standards (ISs). Plasma samples were treated by protein precipitation using acetonitrile. Separation with a gradient elution within 5 min was achieved on C-18(+) column utilizing 5 mM ammonium formate and methanol. An API 4,000 MS in multiple reaction monitoring mode with transitions of 407.1 -> 361.1 and 423.1 -> 347.1 was utilized. Albumin solution was used as a surrogate matrix, with good linearities over the concentration of 1.20-300 ng/mL for COR and 0.0400-10.0 ng/mL for 6 beta-OHCOR. The precisions for intrarun and interrun were < 6.8%, and the accuracy was fell in the interval of -5.2 to 3.5%. Matrix effect was not found. Recovery was close to 100.0%. Stability was confirmed under the storage and processing conditions. The validated method was applied to evaluate the inhibitory effect of voriconazole to CYP3A by the ratio of 6 beta-OHCOR to COR.
引用
收藏
页码:130 / 139
页数:10
相关论文
共 50 条
  • [41] Simultaneous determination of plasma total homocysteine and methionine by liquid chromatography-tandem mass spectrometry
    Jiang, Yi
    Mistretta, Brandon
    Elsea, Sarah
    Sun, Qin
    CLINICA CHIMICA ACTA, 2017, 464 : 93 - 97
  • [42] Determination of Cefotiam in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry
    Du Ping
    Li Peng-Fei
    Liu Hong-Chuan
    Yu Wei-Yue
    Liu Li-Hong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (06) : 876 - 881
  • [43] Determination of picamilon concentration in human plasma by liquid chromatography-tandem mass spectrometry
    Cui, Wenqi
    Chen, Xiaoyan
    Zhan, Yan
    Zhang, Zhenzhong
    Zhang, Yifan
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (15-16): : 1181 - 1184
  • [44] Determination of cinacalcet hydrochloride in human plasma by liquid chromatography-tandem mass spectrometry
    Yang, Fen
    Wang, Hongyun
    Zhao, Qian
    Liu, Hongzhong
    Hu, Pei
    Jiang, Ji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 61 : 237 - 241
  • [45] Determination of tandospirone in human plasma by a liquid chromatography-tandem mass spectrometry method
    Jin, Fengdan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) : 2881 - 2887
  • [46] Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Trimetazidine in Human Plasma
    Zou, Jianjun
    Dai, Li
    Wang, Guang Ji
    Zhu, Yubing
    Fan, Hongwei
    Xiao, Da Wei
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2008, 58 (09): : 429 - 434
  • [47] Determination of mildronate in human plasma and urine by liquid chromatography-tandem mass spectrometry
    Lv, Yun-Feng
    Hu, Xin
    Bi, Kai-Shun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 35 - 39
  • [48] Determination of arotinoid acid in human plasma by liquid chromatography-tandem mass spectrometry
    Deng, Pan
    Chen, Xiaoyan
    Tang, Yunbiao
    Wang, Yongqing
    Zhang, Hongwen
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (27): : 2983 - 2988
  • [49] Determination of loperamide in human plasma and saliva by liquid chromatography-tandem mass spectrometry
    Arafat, Tawfiq
    Arafat, Basil
    Awad, Riad
    Abu Awwad, Ahmad
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 972 : 81 - 88
  • [50] Determination of faropenem in human plasma and urine by liquid chromatography-tandem mass spectrometry
    Gao, Shouhong
    Chen, Wansheng
    Tao, Xia
    Miao, Haijun
    Yang, Shaolin
    Wu, Rong
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (01) : 5 - 12