Simultaneous Determination of Cortisol and 6β-Hydroxycortisol in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry

被引:0
|
作者
Sun, Lu-Ning [1 ,2 ]
Shen, Ye [1 ]
Yang, Yu-Qing [1 ]
Chen, Xiang-Long [1 ]
Huang, Feng-Ru [1 ]
Wang, Dun-Jian [1 ]
Zhang, Ye [3 ]
Wang, Da-Wei [4 ]
Wang, Yong-Qing [1 ,2 ]
机构
[1] Nanjing Med Univ, Affiliated Hosp 1, Res Div Clin Pharmacol, Nanjing 210029, Peoples R China
[2] Nanjing Med Univ, Sch Pharm, Nanjing 210029, Peoples R China
[3] Nanjing Jinling Hosp, Dept Pharm, Nanjing 211166, Peoples R China
[4] Nanjing Univ Chinese Med, Affiliated Hosp Integrated Tradit Chinese & Weste, Nanjing 210028, Peoples R China
关键词
ERYTHROMYCIN BREATH TEST; CYP3A ACTIVITY; MIDAZOLAM MICRODOSE; ORAL MIDAZOLAM; MARKERS; INHIBITION; CLEARANCE; ENZYMES; PROBES; URINE;
D O I
10.1093/chromsci/bmac038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The feasibility of taking the ratio of 6 beta-hydroxycortisol (6 beta-OHCOR) to cortisol (COR) in plasma as a biomarker to reflect CYP3A4 activity needs to be verified, but the low concentration of 6 beta-OHCOR which is an endogenous substance in plasma presents a challenge for determination. In this study, a Liquid chromatography with tandem mass spectrometry (LC-MS/MS) method was established to simultaneously quantify the COR and 6 beta-OHCOR in plasma with COR-d4 and 6 beta-OHCOR-d4 as internal standards (ISs). Plasma samples were treated by protein precipitation using acetonitrile. Separation with a gradient elution within 5 min was achieved on C-18(+) column utilizing 5 mM ammonium formate and methanol. An API 4,000 MS in multiple reaction monitoring mode with transitions of 407.1 -> 361.1 and 423.1 -> 347.1 was utilized. Albumin solution was used as a surrogate matrix, with good linearities over the concentration of 1.20-300 ng/mL for COR and 0.0400-10.0 ng/mL for 6 beta-OHCOR. The precisions for intrarun and interrun were < 6.8%, and the accuracy was fell in the interval of -5.2 to 3.5%. Matrix effect was not found. Recovery was close to 100.0%. Stability was confirmed under the storage and processing conditions. The validated method was applied to evaluate the inhibitory effect of voriconazole to CYP3A by the ratio of 6 beta-OHCOR to COR.
引用
收藏
页码:130 / 139
页数:10
相关论文
共 50 条
  • [11] Determination of salivary cortisol by liquid chromatography-tandem mass spectrometry
    Turpeinen, Ursula
    Valimaki, Matti Juhani
    Hamalainen, Esa
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2009, 69 (05): : 592 - 597
  • [12] Simultaneous determination of triazolam and its metabolites in human plasma by liquid chromatography-tandem mass spectrometry
    Pan, Ryh-Nan
    Lin, Chang-Ching
    Huang, Pei-Wei
    Hsiong, Cheng-Huei
    Pao, Li-Heng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 872 (1-2): : 58 - 62
  • [13] Simultaneous determination of hydrochlorothiazide, quinapril and quinaprilat in human plasma by liquid chromatography-tandem mass spectrometry
    Parekh, Sagar A.
    Pudage, Ashutosh
    Joshi, Santosh S.
    Vaidya, Vikas V.
    Gomes, Noel A.
    Kamat, Sudhir S.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 873 (01): : 59 - 69
  • [14] Determination of tiropramide in human plasma by liquid chromatography-tandem mass spectrometry
    Lee, HW
    Ji, HY
    Kim, HH
    Cho, HY
    Lee, YB
    Lee, HS
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (02): : 395 - 400
  • [15] Determination of silodosin in human plasma by liquid chromatography-tandem mass spectrometry
    Zhao, Xia
    Liu, Yuwang
    Xu, Junyu
    Zhang, Dan
    Zhou, Ying
    Gu, Jingkai
    Cui, Yimin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29): : 3724 - 3728
  • [16] Simultaneous determination of ivabradine and its metabolites in human plasma by liquid chromatography-tandem mass spectrometry
    François-Bouchard, M
    Simonin, G
    Bossant, MJ
    Boursier-Neyret, C
    JOURNAL OF CHROMATOGRAPHY B, 2000, 745 (02): : 261 - 269
  • [17] Determination of Mebudipine in Human Plasma by Liquid Chromatography-tandem Mass Spectrometry
    Asgari, Arezoo
    Kobarfard, Farzad
    Keyhanfar, Fariborz
    Mohebbi, Shohreh
    Noubarani, Maryam
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2015, 14 (03): : 739 - 746
  • [18] Determination of nicousamide in human plasma by liquid chromatography-tandem mass spectrometry
    Qi, Wenyuan
    Zhao, Qian
    Liu, Hongzhong
    Jiang, Ji
    Chen, Xiaoguang
    Hu, Pei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 77 : 158 - 162
  • [19] Determination of solifenacin in human plasma by liquid chromatography-tandem mass spectrometry
    Macek, Jan
    Ptacek, Pavel
    Klima, Josef
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (31): : 3327 - 3330
  • [20] Determination of captopril in human plasma by liquid chromatography-tandem mass spectrometry
    Zhao Limei
    Hu Ligang
    Jiang Yao
    Wang Jiang
    Wang Ling
    Gu Jingkai
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (11) : 1599 - 1602