A Multi-Laboratory Evaluation of Commercial Monkeypox Virus Molecular Tests

被引:2
|
作者
Erster, Oran [1 ]
Levy, Itzchak [2 ]
Kabat, Areej [1 ]
Mannasse, Batya [1 ]
Levy, Virginia [1 ]
Assraf, Hadar [1 ]
Azar, Roberto [1 ]
Ben-Zvi, Haim [3 ]
Bradenstein, Ritta [4 ]
Bunder, Olga [5 ]
Fadeela, Ayman [6 ]
Keren-Naus, Ayelet [7 ]
Peretz, Avi [8 ,9 ]
Roif-Kaminsky, Diana [10 ]
Saleh, Lolu [3 ]
Schreiber, Licita [11 ]
Schwartz, Orna [12 ]
Shaked-Mishan, Pninit [13 ]
Sorek, Nadav [14 ]
Strauss, Merav [15 ]
Steinberg, Rachel [7 ]
Treygerman, Orit [16 ]
Zisman-Rozen, Simona [17 ]
Yishai, Ruth [18 ]
Tejman-Yarden, Noa [18 ]
Mendelson, Ella [1 ,19 ]
Sofer, Danit [1 ]
机构
[1] Chaim Sheba Med Ctr, Cent Virol Lab, Publ Hlth Serv, Minist Hlth, Ramat Gan, Israel
[2] Chaim Sheba Med Ctr, Infect Dis Unit, Ramat Gan, Israel
[3] Beilinson Rabin Med Ctr, Petah Tiqwa, Israel
[4] Kaplan Med Ctr, Rehovot, Israel
[5] Shamir Med Ctr, Beer Yaacov Zerifin, Israel
[6] Meir Med Ctr, Kefar Sava, Israel
[7] Soroka Med Ctr, Beer Sheva, Israel
[8] Baruch Padeh Med Ctr, Tiberias, Israel
[9] Bar Ilan Univ, Azrieli Fac Med, Safed, Israel
[10] Barzilai Govt Hosp, Ashqelon, Israel
[11] Maccabi HealthCare Cent Lab, Rehovot, Israel
[12] Wolfson Med Ctr, Holon, Israel
[13] Carmel Hosp, Haifa, Israel
[14] Assuta Ashdod Univ Hosp, Ashdod, Israel
[15] Emek Med Ctr, Afula, Israel
[16] Meuchedet HealthCare Cent Lab, Lod, Israel
[17] Galilee Med Ctr, Nahariyya, Israel
[18] Minist Hlth, Dept Labs, Publ Hlth Serv, Jerusalem, Israel
[19] Tel Aviv Univ, Sch Publ Hlth, Sackler Fac Med, Tel Aviv, Israel
关键词
monkeypox; real-time PCR; detection kit; comparative analysis; molecular diagnostics; PCR; commercial kit; validation; DIFFERENTIATION; ASSAYS;
D O I
10.1128/spectrum.00225-23
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
In this report, we describe the first national scale multi-laboratory evaluation of monkeypox virus (MPXV) DNA commercial PCR kits. The objective of this study was to evaluate 2 kits by different diagnostic laboratories across Israel. Ten standardized samples were tested simultaneously using the Novaplex (15 laboratories) and Bio-Speedy (seven laboratories) kits. An in-house assay based on previously published reactions was used as reference. Comparison of the results showed high intra-assay agreement between laboratories, with small variations for most samples. The in-house assay had an analytical detection limit of less than 10 copies per reaction. While the 2 commercial kits were able to detect specimens with low viral loads similarly to the in-house assay, significant differences were observed, in the Cq values and relative fluorescence (RF), between the assays. The RF signal of the in-house and Bio-Speedy assays ranged between 5,000 and 10,000 RFU, while the signal in the Novaplex assay was less than 600 RFU. Due to the kit measurement protocol, the Cq values of the Bio-Speedy kit were 5 to 7.5 cycles lower than those of the in-house assay. On the contrary, the Cq values of the Novaplex kit were significantly higher than those of the in-house assay, with differences of 3 to 5 cycles per sample. Our results suggest that while all assays were similar in their overall sensitivity, direct comparison of Cq values between them may be misleading. To our knowledge, this is the first methodical evaluation of commercial MPX test kits. We therefore anticipate that this study would help diagnostic laboratories in choosing a specific MPX detection assay. IMPORTANCE To the best of our knowledge, this study is the first methodical evaluation of commercial kits designed for Monkeypox virus detection. This was done by performing the same tests using the same sample set in multiple laboratories, simultaneously, on a national scale. It therefore provides important and unique information on the performance of such kits and provides a guideline for choosing the assay of choice for monkeypox virus diagnosis in a standard diagnostic laboratory. It also demonstrates potential complications when trying to compare the results of different assays, even when testing exactly the same samples, under identical conditions.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Evaluation of a ddPCR Commercial Assay for the Absolute Quantification of the Monkeypox Virus West Africa in Clinical Samples
    Pomari, Elena
    Mori, Antonio
    Accordini, Silvia
    Donini, Annalisa
    Cordioli, Maddalena
    Tacconelli, Evelina
    Castilletti, Concetta
    DIAGNOSTICS, 2023, 13 (07)
  • [42] A multi-laboratory evaluation of a clinically-validated incurred quality control material for analysis of allergens in food
    Johnson, Phil E.
    Rigby, Neil M.
    Dainty, Jack R.
    Mackie, Alan R.
    Immer, Ulrike U.
    Rogers, Adrian
    Titchener, Pauline
    Shoji, Masahiro
    Ryan, Anne
    Mata, Luis
    Brown, Helen
    Holzhauser, Thomas
    Dumont, Valery
    Wykes, Jill A.
    Walker, Michael
    Griffin, Jon
    White, Jane
    Taylor, Glenn
    Popping, Bert
    Crevel, Rene
    Miguel, Sonia
    Lutter, Petra
    Gaskin, Ferdelie
    Koerner, Terry B.
    Clarke, Dean
    Sherlock, Robin
    Flanagan, Andrew
    Chan, Chun-Han
    Mills, E. N. Clare
    FOOD CHEMISTRY, 2014, 148 : 30 - 36
  • [43] A multi-laboratory evaluation of an enzyme-linked immunoassay quantitating human antibodies to Streptococcus pneumoniae polysaccharides
    Quataert, S
    Martin, D
    Anderson, P
    Giebink, GS
    Henrichsen, J
    Leinonen, M
    Granoff, DM
    Russell, H
    Siber, G
    Faden, H
    Barnes, D
    Madore, DV
    IMMUNOLOGICAL INVESTIGATIONS, 2001, 30 (03) : 191 - 207
  • [44] In vitro digestibility of β-casein and β-lactoglobulin under simulated human gastric and duodenal conditions: A multi-laboratory evaluation
    Mandalari, G.
    Adel-Patient, K.
    Barkholt, V.
    Baro, C.
    Bennett, L.
    Bublin, M.
    Gaier, S.
    Graser, G.
    Ladics, G. S.
    Mierzejewska, D.
    Vassilopoulou, E.
    Vissers, Y. M.
    Zuidmeer, L.
    Rigby, N. M.
    Salt, L. J.
    Defernez, M.
    Mulholland, F.
    Mackie, A. R.
    Wickham, M. S. J.
    Mills, E. N. C.
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2009, 55 (03) : 372 - 381
  • [45] Monkeypox virus: insights into pathogenesis and laboratory testing methods
    Kumar, Anoop
    Singh, Neeraj
    Anvikar, Anupkumar R.
    Misra, Gauri
    3 BIOTECH, 2024, 14 (03)
  • [46] Monkeypox virus: insights into pathogenesis and laboratory testing methods
    Anoop Kumar
    Neeraj Singh
    Anupkumar R. Anvikar
    Gauri Misra
    3 Biotech, 2024, 14
  • [47] Evaluation of the diagnostic performance of a commercial molecular assay for the screening of suspected monkeypox cases in Sri Lanka
    Harshani, H. B. C.
    Liyanage, G. A.
    Ruwan, D. V. R. G.
    Samaraweera, U. K. I. U.
    Abeynayake, J. I.
    INFECTIOUS MEDICINE, 2023, 2 (02): : 136 - 142
  • [48] Three years of multi-laboratory external quality control for the molecular detection of Toxoplasma gondii in amniotic fluid in France
    Bastien, P.
    Jumas-Bilak, E.
    Varlet-Marie, E.
    Marty, P.
    CLINICAL MICROBIOLOGY AND INFECTION, 2007, 13 (04) : 430 - 433
  • [49] Accuracy of Molecular Diagnostic Tests for Monkeypox: Different Tests and Clinical Samples
    Sriwijitalai, Won
    Wiwanitkit, Viroj
    CLINICAL LABORATORY, 2023, 69 (05) : 1050 - 1051
  • [50] Lane Change Test: Preliminary Results of a Multi-Laboratory Calibration Study
    Bengler, Klaus
    Mattes, Stefan
    Hamm, Otmar
    Hensel, Martin
    PERFORMANCE METRICS FOR ASSESSING DRIVER DISTRACTION: THE QUEST FOR IMPROVED ROAD SAFETY, 2010, : 243 - 253