Transosseous Repair With Nice Knot Augmentation Versus Knotless Suture Anchor Repair With Suture Tape for Quadriceps Tendon Rupturer A Cadaveric Study

被引:0
|
作者
Duell, Bryan [1 ,3 ]
Long, Mitchell K. [1 ]
Divella, Michael [1 ]
Fogel, Joshua [2 ]
Ruotolo, Charles [1 ]
机构
[1] Nassau Univ, Med Ctr, Dept Orthoped, East Meadow, NY USA
[2] Brooklyn Coll, Dept Business Management, Brooklyn, NY USA
[3] Nassau Univ, Med Ctr, Dept Orthoped, 2201 Hempstead Turnpike, East Meadow, NY 11554 USA
关键词
FOLLOW-UP; OUTCOMES; FIXATION;
D O I
10.3928/01477447-20221207-02
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Quadriceps tendon rupture is typically repaired using either transosseous tunnels or suture anchors. Recent literature has suggested that suture an- chor repair is biomechanically superior to the use of transosseous tunnels. Augmentation of the transosseous technique with Nice knots may result in improved biomechanical properties as compared with a suture anchor construct. To compare biomechanical properties of a novel transosseous quadriceps tendon repair technique with Nice knot augmentation to those of knotless suture anchor repair, an artificial quadriceps tendon rupture was created in 10 matched pairs of cadaveric knees (n=20). Each cadaver was subjected to biomechanical testing to calculate the average ultimate load to failure, repair site gapping after early and late cyclic loading, and stiffness. Transosseous repair augmented with Nice knots as compared with knotless suture anchor repair had greater load to failure (mean +/- SD, 1489.5 +/- 297.6 N vs 717.7 +/- 191.4 N, P<.001), decreased gapping after early and late cyclic loading (cycles 1-20: mean +/- SD, 0.59 +/- 0.4 mm vs 2.1 +/- 1.2 mm, P=.008; cycles 21-250: mean +/- SD, 1.2 +/- 0.7 mm vs 3.9 +/- 1.7 mm, P=.002), and greater con- struct stiffness (mean +/- SD, 80.7 +/- 15.7 N/mm vs 44.4 +/- 13.4 N/mm, P=.001). The transosseous quadriceps tendon repair technique with Nice knot aug- mentation is biomechanically better than knotless suture anchor repair with regard to ultimate load to failure, gap formation after cyclic loading, and con- struct stiffness in cadaveric specimens.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
  • [41] A Knotless Suture Anchor: Technique for use in arthroscopic Bankart repair
    Thal, R
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2001, 17 (02): : 213 - 218
  • [42] Lateral Epicondylitis Debridement and Repair Using Knotless Suture Anchor
    Donaldson, Christopher T.
    Finley, Zachary J.
    O'Brien, Michael J.
    ARTHROSCOPY TECHNIQUES, 2019, 8 (07): : E775 - E779
  • [43] Suture Bridge Transosseous Quadriceps Tendon Repair for Spontaneous Quadriceps Tendon Rupture in Patients With End-Stage Renal Disease
    Srimongkolpitak, Surasak
    Chernchujit, Bancha
    Apivatgaroon, Adinun
    Taweekitikul, Pariwat
    ARTHROSCOPY TECHNIQUES, 2022, 11 (11): : E2073 - E2080
  • [44] Clinical and biomechanical outcomes following patellar tendon repair with suture tape augmentation
    Maximilian Hinz
    Stephanie Geyer
    Felix Winden
    Alexander Braunsperger
    Florian Kreuzpointner
    Markus Irger
    Andreas B. Imhoff
    Julian Mehl
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 3569 - 3576
  • [45] Clinical and biomechanical outcomes following patellar tendon repair with suture tape augmentation
    Hinz, Maximilian
    Geyer, Stephanie
    Winden, Felix
    Braunsperger, Alexander
    Kreuzpointner, Florian
    Irger, Markus
    Imhoff, Andreas B.
    Mehl, Julian
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (08): : 3569 - 3576
  • [46] Arthroscopic Anterior Cruciate Ligament Primary Repair With Synthetic Augmentation and Fixation With the Knotless Suture Anchor
    Itthipanichpong, Thun
    Tangboonnitiwong, Napol
    Limskul, Danaithep
    Tanpowpong, Thanathep
    Kuptniratsaikul, Somsak
    Thamrongskulsiri, Napatpong
    ARTHROSCOPY TECHNIQUES, 2023, 12 (07): : E1009 - E1013
  • [47] Thumb Metacarpophalangeal Joint Ulnar Collateral Ligament: Early Outcomes of Suture Anchor Repair with Suture Tape Augmentation
    Patel, Shaan S.
    Hachadorian, Michael
    Gordon, Amber
    Nydick, Jason
    Garcia, Michael
    JOURNAL OF HAND AND MICROSURGERY, 2022, 14 (01) : 25 - 30
  • [48] Suture anchor repair yields better biomechanical properties than transosseous sutures in ruptured quadriceps tendons
    Petri, M.
    Dratzidis, A.
    Brand, S.
    Calliess, T.
    Hurschler, C.
    Krettek, C.
    Jagodzinski, M.
    Ettinger, M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (04) : 1039 - 1045
  • [49] Suture anchor repair yields better biomechanical properties than transosseous sutures in ruptured quadriceps tendons
    M. Petri
    A. Dratzidis
    S. Brand
    T. Calliess
    C. Hurschler
    C. Krettek
    M. Jagodzinski
    M. Ettinger
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 1039 - 1045
  • [50] Suture Tape Augmentation for Scapholunate Ligament Repair: A Biomechanical Study
    Thompson, R. Gil
    Dustin, Joel A.
    Roper, D. Keith
    Kane, Steven M.
    Lourie, Gary M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2021, 46 (01): : 36 - 42