Transosseous Repair With Nice Knot Augmentation Versus Knotless Suture Anchor Repair With Suture Tape for Quadriceps Tendon Rupturer A Cadaveric Study

被引:0
|
作者
Duell, Bryan [1 ,3 ]
Long, Mitchell K. [1 ]
Divella, Michael [1 ]
Fogel, Joshua [2 ]
Ruotolo, Charles [1 ]
机构
[1] Nassau Univ, Med Ctr, Dept Orthoped, East Meadow, NY USA
[2] Brooklyn Coll, Dept Business Management, Brooklyn, NY USA
[3] Nassau Univ, Med Ctr, Dept Orthoped, 2201 Hempstead Turnpike, East Meadow, NY 11554 USA
关键词
FOLLOW-UP; OUTCOMES; FIXATION;
D O I
10.3928/01477447-20221207-02
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Quadriceps tendon rupture is typically repaired using either transosseous tunnels or suture anchors. Recent literature has suggested that suture an- chor repair is biomechanically superior to the use of transosseous tunnels. Augmentation of the transosseous technique with Nice knots may result in improved biomechanical properties as compared with a suture anchor construct. To compare biomechanical properties of a novel transosseous quadriceps tendon repair technique with Nice knot augmentation to those of knotless suture anchor repair, an artificial quadriceps tendon rupture was created in 10 matched pairs of cadaveric knees (n=20). Each cadaver was subjected to biomechanical testing to calculate the average ultimate load to failure, repair site gapping after early and late cyclic loading, and stiffness. Transosseous repair augmented with Nice knots as compared with knotless suture anchor repair had greater load to failure (mean +/- SD, 1489.5 +/- 297.6 N vs 717.7 +/- 191.4 N, P<.001), decreased gapping after early and late cyclic loading (cycles 1-20: mean +/- SD, 0.59 +/- 0.4 mm vs 2.1 +/- 1.2 mm, P=.008; cycles 21-250: mean +/- SD, 1.2 +/- 0.7 mm vs 3.9 +/- 1.7 mm, P=.002), and greater con- struct stiffness (mean +/- SD, 80.7 +/- 15.7 N/mm vs 44.4 +/- 13.4 N/mm, P=.001). The transosseous quadriceps tendon repair technique with Nice knot aug- mentation is biomechanically better than knotless suture anchor repair with regard to ultimate load to failure, gap formation after cyclic loading, and con- struct stiffness in cadaveric specimens.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
  • [31] Knot-Tying versus Knotless Suture Anchors for Arthroscopic Bankart Repair: A Comparative Study
    Shim, Jae Woo
    Jung, Tae Wan
    Kim, Il Su
    Yoo, Jae Chul
    YONSEI MEDICAL JOURNAL, 2021, 62 (08) : 743 - 749
  • [32] Flexor Tendon Repair With a Knotless Barbed Suture: A Comparative Biomechanical Study
    Marrero-Amadeo, Ian C.
    Chauhan, Aakash
    Warden, Stuart J.
    Merrell, Gregory A.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (07): : 1204 - 1208
  • [33] Suture anchor versus suture through tunnel fixation for quadriceps tendon rupture: A biomechanical study
    Lighthart, William A.
    Cohen, David A.
    Levine, Richard G.
    Parks, Brent G.
    Boucher, Henry R.
    ORTHOPEDICS, 2008, 31 (05) : 441 - 441
  • [34] Flexor tendon repair: a comparative study between a knotless barbed suture repair and a traditional four-strand monofilament suture repair
    Joyce, C. W.
    Whately, K. E.
    Chan, J. C.
    Murphy, M.
    O'Brien, F. J.
    Carroll, S. M.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2014, 39 (01) : 40 - 45
  • [35] Anterolateral Ligament Repair With Suture Tape Augmentation
    Heusdens, Christiaan H. W.
    Hopper, Graeme P.
    Dossche, Lieven
    Mackay, Gordon M.
    ARTHROSCOPY TECHNIQUES, 2018, 7 (12): : E1311 - E1314
  • [36] Suture anchor offers knotless fixation in rotator cuff repair
    不详
    ADVANCED MATERIALS & PROCESSES, 2013, 171 (09): : 6 - 6
  • [37] Posterolateral Corner Repair With Suture Tape Augmentation
    Hopper, Graeme P.
    Heusdens, Christiaan H. W.
    Dossche, Lieven
    Mackay, Gordon M.
    ARTHROSCOPY TECHNIQUES, 2018, 7 (12): : E1299 - E1303
  • [38] Arthroscopic Hip Labral Repair With Knotless FiberTak Suture Anchor
    Nasra, Matthew
    Vasavada, Kinjal
    Yao, Kaisen
    Sugarman, Etan
    ARTHROSCOPY TECHNIQUES, 2024, 13 (07):
  • [39] Biomechanical Comparison of a Knotless Suture Anchor With Standard Suture Anchor in the Repair of Type II SLAP Tears
    Sileo, Michael J.
    Lee, Steven J.
    Kremenic, Ian J.
    Orishimo, Karl
    Ben-Avi, Simon
    McHugh, Malachy
    Nicholas, Stephen J.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (04): : 348 - 354
  • [40] Biomechanical Comparison of Knotless Anchor Repair Versus Simple Suture Repair for Type II SLAP Lesions
    Uggen, Christopher
    Wei, Anthony
    Glousman, Ronald E.
    ElAttrache, Neal
    Tibone, James E.
    McGarry, Michelle H.
    Lee, Thay Q.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (10): : 1085 - 1092