The application of a dual-lead locking screw could enhance the reduction and fixation stability of the proximal humerus fractures: a biomechanical evaluation

被引:1
|
作者
Lee, Eunju [1 ]
Jeong, Hyeon Jang [2 ]
Lee, Yeon Soo [1 ]
Oh, Joo Han [2 ]
机构
[1] Daegu Catholic Univ, Sch BioMed Sci, Dept BioMed Engn, Gyungbuk, South Korea
[2] Seoul Natl Univ, Coll Med, Bundang Hosp, Dept Orthopaed Surg, Seoul, South Korea
来源
FRONTIERS IN SURGERY | 2024年 / 11卷
关键词
proximal humerus; locked plating; dual-lead; lead ratio; compression; bone crush; insertion torque; stability; PLATE; BONE; STRENGTH;
D O I
10.3389/fsurg.2024.1333670
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Bicortical screw fixation, which penetrates and fixes the near and far cortex of bone, has been conventionally used to achieve compressive fixation for fracture using screws. Open reduction and internal fixation using the locking plate are widely used for treating proximal humerus fractures. However, minimal contact between the bone and the locking plate can lead to an insufficient reduction. Theoretically, a dual-lead locking screw with different leads for the screw head and body could enhance the reduction and fixation stability of fragments in proximal humeral fractures without bicortical fixation, and achieve additional compression at the bone-plate-screw interface. This study assessed the insertion mechanics of the lead ratio of the dual-lead locking screw and its effect on the fixation stability of the proximal humerus fracture. Methods: A Multi-Fix (R) locking plating system composed of & empty;& empty; 3.5 mm locking screws and a locking plate was used to make a locked plating for Sawbone bone blocks and fourth-generation composite humeri. Two different types of Sawbone bone blocks were used to simulate the osteoporotic (10 PCF) and normal cancellous (20 PCF) bones. The lead of the screw head thread (L-head) was 0.8 mm, and that of the screw body (L-body) was 0.8, 1.25, 1.6, 2.0, and 2.4 mm, whose lead ratios (Rlead=L-body/L-head) were 1.0, 1.56, 2.0, 2.5, and 3.0, respectively. Results: The dual-lead locking screw elevated the compression between the locking plate and the bone. The elevation in the compression due to the dual-lead thread became weaker for the cancellous bone when the lead of the screw body was more than twice that of the screw head. The plate/humerus compression with strong bone quality withstood higher dual-lead-driven compression. Discussion: A dual-lead locking screw of L-body=1.25mm (R-lead=1.56) is recommended for maximum rotational stability for the locked humerus plating. The screws with over L-body=1.6mm (R-lead=2) have no advantage in terms of the failure torque and maximum torsional deformation. Any locking dual-lead screw with a body thread lead of <1.6 mm (R-lead=2) can be used without the risk of bone crush when surgeons require additional compression to the locked cancellous bone plating.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Locked plate fixation and intramedullary nailing for proximal humerus fractures: A biomechanical evaluation
    Hessmann, MH
    Hansen, WSM
    Krummenauer, F
    Pol, TF
    Rommens, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 58 (06): : 1194 - 1201
  • [12] Anatomical and biomechanical evaluation of an intramedullary nail for fractures of proximal humerus fractures based on tuberosity fixation
    Clavert, Ph.
    Hatzidalds, A.
    Boileau, P.
    CLINICAL BIOMECHANICS, 2016, 32 : 108 - 112
  • [13] Biomechanical evaluation of a new gliding screw concept for the fixation of proximal humeral fractures
    Acklin, Y. P.
    Zderic, I
    Inzana, J. A.
    Grechenig, S.
    Schwyn, R.
    Richards, R. G.
    Gueorguiev, B.
    BONE & JOINT RESEARCH, 2018, 7 (06): : 422 - 429
  • [14] Enhancing fixation stability in proximal humerus fractures: screw orientation optimization in PHILOS plates through finite element analysis and biomechanical testing
    Liu, Jichao
    Zhang, Ziyan
    Li, Peng
    Piao, Chengdong
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [15] Biomechanical evaluation of novel intra- and extramedullary assembly fixation for proximal humerus fractures in the elderly
    Zhu, Zhengguo
    Chang, Zuhao
    Zhang, Wei
    Qi, Hongzhe
    Guo, Hao
    Li, JiaQi
    Qi, Lin
    Nie, Shaobo
    Tang, Peifu
    Liang, Yonghui
    Wei, Xing
    Chen, Hua
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [16] Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model
    Walsh, Stephen
    Reindl, Rudy
    Harvey, Edward
    Berry, Gregory
    Beckman, Lorne
    Steffen, Thomas
    CLINICAL BIOMECHANICS, 2006, 21 (10) : 1027 - 1031
  • [17] Dual Plate Screw Fixation for Distal Humerus Fractures Based on Stability and Interfragmentary Relative Motion
    Abrishamiyan, Mohammad
    Kiani, Rozhan
    Nourani, Amir
    Farahmand, Farzam
    2023 30TH NATIONAL AND 8TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2023, : 39 - 46
  • [18] The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus
    Bae, J. -H.
    Oh, J. -K.
    Chon, C. -S.
    Oh, C. -W.
    Hwang, J. -H.
    Yoon, Y. -C.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (07): : 937 - 941
  • [19] Comparison of effective factors in loss of reduction after locking plate-screw treatment in humerus proximal fractures
    Adiyeke, Levent
    Gecer, Ali
    Bulut, Oguzhan
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2022, 28 (07): : 1008 - 1015
  • [20] Biomechanical Evaluation of Locking Plate Fixation of Proximal Humeral Fractures Augmented With Calcium Phosphate Cement
    Gradl, Gertraud
    Knobe, Matthias
    Stoffel, Marcus
    Prescher, Andreas
    Dirrichs, Timm
    Pape, Hans-Christoph