A nonconvex model-based combined geometric calibration scheme for micro cone-beam CT with irregular trajectories

被引:5
|
作者
Li, Guang [1 ]
Chen, Xue [1 ]
You, Chenyu [2 ]
Huang, Xinhai [1 ]
Deng, Zhenhao [1 ]
Luo, Shouhua [1 ]
机构
[1] Southeast Univ, Dept Biomed Engn, Jiangsu Key Lab Biomat & Devices, Nanjing, Peoples R China
[2] Yale Univ, Image Proc & Anal Grp IPAG, New Haven, CT USA
基金
中国国家自然科学基金;
关键词
cone-beam CT; geometric calibration; irregular trajectory; MISALIGNMENT CORRECTION; SELF-CALIBRATION; PARAMETERS; RECONSTRUCTION; OPTIMIZATION; ALIGNMENT; DETECTOR; SYSTEMS;
D O I
10.1002/mp.16257
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundMany dedicated cone-beam CT (CBCT) systems have irregular scanning trajectories. Compared with the standard CBCT calibration, accurate calibration for CBCT systems with irregular trajectories is a more complex task, since the geometric parameters for each scanning view are variable. Most of the existing calibration methods assume that the intrinsic geometric relationship of the fiducials in the phantom is precisely known, and rarely delve deeper into the issue of whether the phantom accuracy is adapted to the calibration model. PurposeA high-precision phantom and a highly robust calibration model are interdependent and mutually supportive, and they are both important for calibration accuracy, especially for the high-resolution CBCT. Therefore, we propose a calibration scheme that considers both accurate phantom measurement and robust geometric calibration. MethodsOur proposed scheme consists of two parts: (1) introducing a measurement model to acquire the accurate intrinsic geometric relationship of the fiducials in the phantom; (2) developing a highly noise-robust nonconvex model-based calibration method. The measurement model in the first part is achieved by extending our previous high-precision geometric calibration model suitable for CBCT with circular trajectories. In the second part, a novel iterative method with optimization constraints based on a back-projection model is developed to solve the geometric parameters of each view. ResultsThe simulations and real experiments show that the measurement errors of the fiducial ball bearings (BBs) are within the subpixel level. With the help of the geometric relationship of the BBs obtained by our measurement method, the classic calibration method can achieve good calibration based on far fewer BBs. All metrics obtained in simulated experiments as well as in real experiments on Micro CT systems with resolutions of 9 and 4.5 mu m show that the proposed calibration method has higher calibration accuracy than the competing classic method. It is particularly worth noting that although our measurement model proves to be very accurate, the classic calibration method based on this measurement model can only achieve good calibration results when the resolution of the measurement system is close to that of the system to be calibrated, but our calibration scheme enables high-accuracy calibration even when the resolution of the system to be calibrated is twice that of the measurement system. ConclusionsThe proposed combined geometrical calibration scheme does not rely on a phantom with an intricate pattern of fiducials, so it is applicable in Micro CT with high resolution. The two parts of the scheme, the "measurement model" and the "calibration model," prove to be of high accuracy. The combination of these two models can effectively improve the calibration accuracy, especially in some extreme cases.
引用
收藏
页码:2759 / 2774
页数:16
相关论文
共 50 条
  • [41] Implementation & evaluation of the half-scan scheme based on CBCT (cone-beam CT) system
    Dong, Y
    Ning, RL
    Yu, Y
    Conover, D
    Lu, XH
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 542 - 551
  • [42] Self-Geometric Calibration of Circular Cone Beam CT Based On Epipolar Geometry Consistency
    Zheng, Liang
    Luo, Shouhua
    Chen, Lujie
    Luo, Shuang
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [43] Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT
    Zbijewski, Wojciech
    Beekman, Freek J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) : 817 - 827
  • [44] GPU-based 3D cone-beam CT image reconstruction: application to micro CT
    Zhao, Xing
    Bian, Junguo
    Sidky, Emil Y.
    Cho, Seungryong
    Zhang, Peng
    Pan, Xiaochuan
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3922 - +
  • [45] A Parameter Division Based Method for the Geometrical Calibration of X-Ray Industrial Cone-Beam CT
    Xiao, Kai
    Han, Yu
    Xi, Xiaoqi
    Yan, Bin
    Bu, Haibing
    Li, Lei
    IEEE ACCESS, 2018, 6 : 48970 - 48977
  • [46] Fully automatic online geometric calibration for non-circular cone-beam CT orbits using fiducials with unknown placement
    Ma, Yiqun Q.
    Reynolds, Tess
    Ehtiati, Tina
    Weiss, Clifford
    Hong, Kelvin
    Theodore, Nicholas
    Gang, Grace J.
    Stayman, J. Webster
    MEDICAL PHYSICS, 2024, 51 (05) : 3245 - 3264
  • [47] An empirical method for geometric calibration of a photon counting detector-based cone beam CT system
    Ghani, Muhammad Usman
    Makeev, Andrey
    Manus, Joseph A.
    Glick, Stephen J.
    Ghammraoui, Bahaa
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (05) : 865 - 877
  • [48] Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise
    Tilley, Steven, II
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01): : 296 - 319
  • [49] Is model-based dose calculation based on cone-beam computed tomography suitable for adaptive treatment planning in brachytherapy?
    Karius, Andre
    Shariff, Maya
    Schaller, Sabrina
    Lotter, Michael
    Strnad, Vratislav
    Lackner, Niklas
    Fietkau, Rainer
    Bert, Christoph
    Merten, Ricarda
    Schweizer, Claudia
    STRAHLENTHERAPIE UND ONKOLOGIE, 2025, 201 (01) : 57 - 70
  • [50] Cyclegan Based Synthetic CT Model from Cone-Beam CT Images of Pelvic Patients for Adaptive Radiotherapy
    Anbumani, S.
    Paulson, E. S.
    Xu, J.
    Pan, A.
    Thill, D.
    O'Connell, N.
    Shukla, M. E.
    Omari, E. A.
    MEDICAL PHYSICS, 2024, 51 (10) : 7777 - 7778