Experimental verification of seismic vibration control of high-rise buildings with friction-type multiple tuned mass dampers

被引:2
|
作者
Lin, Ging-Long [1 ]
Lin, Chi-Chang [2 ,3 ]
Yang, Tsung-Han [2 ]
Lung, Hao-Yu [2 ]
机构
[1] Natl Kaohsiung Univ Sci & Technol, Kaohsiung, Taiwan
[2] Natl Chung Hsing Univ, Taichung, Taiwan
[3] Chaoyang Univ Technol, Taichung, Taiwan
关键词
Multiple tuned mass dampers; Shaking table test; Optimal design; Friction; Fail-safe device; DYNAMIC CHARACTERISTICS; OPTIMUM DESIGN; PERFORMANCE; OPTIMIZATION; MODEL;
D O I
10.1016/j.engstruct.2023.117401
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent decades, tuned mass damper (TMD) devices have been implemented in numerous high-rise buildings in the world. The vibration of tall buildings caused by natural or man-made dynamic loading poses a challenge. In this study, to ensure structural safety and resident comfort, a friction-type multiple TMD (FT-MTMD) system was investigated and its ability to reduce the seismic response of high-rise buildings was evaluated. The proposed FTMTMD system comprises multiple TMD units in a parallel arrangement and has a greater frequency bandwidth than a conventional TMD system. To address practical issues, a prototype FT-MTMD system was designed and fabricated to control a scale-down test model which has similar fundamental modal properties to a real 36-story building. Because of the nonlinearity of friction, the parameters of the FT-MTMD system were determined using a proposed optimal design method. First, a component test was conducted to ensure that the parameters of the FTMTMD agreed with the designed values. Then, the FT-MTMD was installed on the long-period test model and its control performance was experimentally evaluated. Shaking table test results indicated that the FT-MTMD system favorably reduced the seismic response in the test model, indicating that the proposed optimal design method is reliable. A theoretical structure-MTMD model was also developed to simulate the system response with unsynchronized stick-slip motion of the FT-MTMD system. The predicted system response agreed well with the measured response. In addition, to avoid damage to the FT-MTMD system during a severe earthquake, a failsafe device was employed to lock the TMD when its stroke reached the maximum allowable value.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Seismic response control of base-isolated buildings using multiple tuned mass dampers
    Stanikzai, Mohammad Hamayoun
    Elias, Said
    Matsagar, Vasant A.
    Jain, Arvind K.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2019, 28 (03):
  • [42] Hybrid seismic control of buildings using tuned mass and magnetorheological dampers
    Bhaiya, Vishisht
    Bharti, Shiv Dayal
    Shrimali, Mahendra Kumar
    Datta, Tushar Kanti
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2020, 173 (07) : 471 - 487
  • [43] Rapid algorithm and its application of wind-induced vibration response of super high-rise building under the control of multiple tuned mass dampers
    Li, Xiao-Kang
    Xie, Zhuang-Ning
    Wang, Zhan
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2012, 40 (04): : 118 - 124
  • [44] Optimum study on wind-induced vibration control of high-rise buildings with viscous dampers
    Zhou, Yun
    Wang, DaYang
    Deng, XueSong
    WIND AND STRUCTURES, 2008, 11 (06) : 497 - 512
  • [45] Experimental verification of electromagnetic multiple tuned mass dampers for energy harvesting and structural control
    Lin, Ging-Long
    Lin, Chi-Chang
    Chen, Yu-Jing
    Hung, Ta-Chih
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2021, 50 (13): : 3483 - 3504
  • [46] Application of tuned liquid dampers in controlling the torsional vibration of high rise buildings
    Ross, Andrew S.
    El Damatty, Ashraf A.
    El Ansary, Ayman M.
    WIND AND STRUCTURES, 2015, 21 (05) : 537 - 564
  • [47] Application of tuned liquid dampers in controlling the torsional vibration of high rise buildings
    Ross, Andrew S.
    El Damatty, Ashraf A.
    El Ansary, Ayman M.
    Wind and Structures, An International Journal, 2015, 21 (05): : 537 - 564
  • [48] Passive control of super high-rise buildings using hysteric tuned mass damper
    Kaneko K.
    Kaneko, Kensaku, 2016, Architectural Institute of Japan (81): : 459 - 469
  • [49] Wind vibration control analysis of a supper high-rise structure installed with friction pendulum typed tuned mass damper
    Wu J.
    Zhou Z.
    Liang Q.
    Fu J.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2018, 37 (06): : 142 - 148
  • [50] Review of Vibration Control Strategies of High-Rise Buildings
    El Ouni, Mohamed Hechmi
    Abdeddaim, Mahdi
    Elias, Said
    Ben Kahla, Nabil
    SENSORS, 2022, 22 (21)