Experimental verification of seismic vibration control of high-rise buildings with friction-type multiple tuned mass dampers

被引:2
|
作者
Lin, Ging-Long [1 ]
Lin, Chi-Chang [2 ,3 ]
Yang, Tsung-Han [2 ]
Lung, Hao-Yu [2 ]
机构
[1] Natl Kaohsiung Univ Sci & Technol, Kaohsiung, Taiwan
[2] Natl Chung Hsing Univ, Taichung, Taiwan
[3] Chaoyang Univ Technol, Taichung, Taiwan
关键词
Multiple tuned mass dampers; Shaking table test; Optimal design; Friction; Fail-safe device; DYNAMIC CHARACTERISTICS; OPTIMUM DESIGN; PERFORMANCE; OPTIMIZATION; MODEL;
D O I
10.1016/j.engstruct.2023.117401
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent decades, tuned mass damper (TMD) devices have been implemented in numerous high-rise buildings in the world. The vibration of tall buildings caused by natural or man-made dynamic loading poses a challenge. In this study, to ensure structural safety and resident comfort, a friction-type multiple TMD (FT-MTMD) system was investigated and its ability to reduce the seismic response of high-rise buildings was evaluated. The proposed FTMTMD system comprises multiple TMD units in a parallel arrangement and has a greater frequency bandwidth than a conventional TMD system. To address practical issues, a prototype FT-MTMD system was designed and fabricated to control a scale-down test model which has similar fundamental modal properties to a real 36-story building. Because of the nonlinearity of friction, the parameters of the FT-MTMD system were determined using a proposed optimal design method. First, a component test was conducted to ensure that the parameters of the FTMTMD agreed with the designed values. Then, the FT-MTMD was installed on the long-period test model and its control performance was experimentally evaluated. Shaking table test results indicated that the FT-MTMD system favorably reduced the seismic response in the test model, indicating that the proposed optimal design method is reliable. A theoretical structure-MTMD model was also developed to simulate the system response with unsynchronized stick-slip motion of the FT-MTMD system. The predicted system response agreed well with the measured response. In addition, to avoid damage to the FT-MTMD system during a severe earthquake, a failsafe device was employed to lock the TMD when its stroke reached the maximum allowable value.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Seismic nonlinear vibration control algorithm for high-rise buildings
    Liu, Qian
    Zhang, Weikang
    Bhatt, Mohammed Wasim
    Kumar, Ajit
    NONLINEAR ENGINEERING - MODELING AND APPLICATION, 2021, 10 (01): : 574 - 582
  • [22] Vibration control of high-rise buildings for wind: a robust passive and active tuned mass damper
    Aly, Aly Mousaad
    SMART STRUCTURES AND SYSTEMS, 2014, 13 (03) : 473 - 500
  • [23] Seismic Control of Tall Buildings Using Distributed Multiple Tuned Mass Dampers
    Rahmani, Hamid Radmard
    Koenke, Carsten
    ADVANCES IN CIVIL ENGINEERING, 2019, 2019
  • [24] Vibration control in buildings under seismic excitation using optimized tuned mass dampers
    Brandao, Francisco da Silva
    Fadel Miguel, Leticia Fleck
    FRATTURA ED INTEGRITA STRUTTURALE, 2020, 14 (54): : 66 - 87
  • [25] Intelligent wind vibration control of high-rise buildings using MR dampers
    Yan, Shi
    Zheng, Wei
    Song, Gangbing
    SMART STRUCTURES AND MATERIALS 2006: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL , AND AEROSPACE SYSTEMS, PTS 1 AND 2, 2006, 6174
  • [26] A Seismic vibration and damage control of high-rise structures with the implementation of a pendulum-type nontraditional tuned mass damper
    Xiang, Ping
    Nishitani, Akira
    Wu, Minger
    STRUCTURAL CONTROL & HEALTH MONITORING, 2017, 24 (12):
  • [27] ROBUST OPTIMUM DESIGN OF TUNED MASS DAMPERS FOR HIGH-RISE BUILDINGS UNDER MODERATE EARTHQUAKES
    Marano, Giuseppe Carlo
    Greco, Rita
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2009, 18 (08): : 823 - 838
  • [28] Experimental verification of seismic vibration control using a semi-active friction tuned mass damper
    Lin, Ging-Long
    Lin, Chi-Chang
    Lu, Lyan-Ywan
    Ho, Yu-Bo
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (04): : 813 - 830
  • [29] Seismic control of tall buildings using vertically distributed multiple tuned mass dampers
    Pasand, Ali Akhlagh
    Zahrai, Seyed Mehdi
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2024, 33 (14):
  • [30] Optimum placement and design of multiple tuned mass dampers for vibration control of asymmetric buildings
    Wang, Jer-Fu
    Lin, Ging-Long
    Lin, Chi-Chang
    Jian, Jie-Yong
    JOURNAL OF VIBRATION AND CONTROL, 2022, 28 (23-24) : 3875 - 3889