TiO2/MWCNT/Nafion-Modified Glassy Carbon Electrode as a Sensitive Voltammetric Sensor for the Determination of Hydrogen Peroxide

被引:9
|
作者
de Oliveira, Rafael Henrique [1 ]
Goncalves, Daniel A. [2 ]
dos Reis, Diogo Duarte [1 ]
机构
[1] Fed Univ Mato Grosso Sul UFMS, Inst Phys, BR-79070900 Campo Grande, MS, Brazil
[2] Fed Univ Grande Dourados, Fac Exact Sci & Technol, BR-79804970 Dourados, MS, Brazil
关键词
hydrogen peroxide; electrochemical sensor; nanocomposite; cyclic voltammetry; TiO2; MWCNTs; TIO2; NANOPARTICLES; CYCLIC VOLTAMMETRY; NANOTUBE ARRAYS; NANOCOMPOSITES; NANOMATERIALS; H2O2; PERFORMANCE; REACTIVITY; GRAPHENE; MWCNTS;
D O I
10.3390/s23187732
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work we describe a straightforward approach for creating a nanocomposite comprising multiwalled carbon nanotubes (MWCNTs) and titanium dioxide (TiO2) using the hydrothermal technique, which is then characterized by scanning electron microscope (SEM), energy-dispersive X-ray spectrometer (EDS), X-ray diffraction analysis (XRD), Fourier transform infrared spectroscopy (FTIR), and thermal gravimetric analysis (TGA) to assess its properties. Nafion is employed as a reticular agent for the nanocomposite on the glassy carbon electrode (GCE), creating the MWCNT/TiO2/Nafion/GCE system. The electrochemical behavior of the system was evaluated using cyclic voltammetry, revealing its remarkable electrocatalytic activity for detecting hydrogen peroxide in water. The developed sensor showcased a broad linear response range of 14.00 to 120.00 mu M, with a low detection limit of 4.00 mu M. This electrochemical sensor provides a simple and highly sensitive method for detecting hydrogen peroxide in aqueous solutions and shows promising potential for various real-world applications, particularly in H2O2 monitoring.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] A biocompatible nano TiO2/nafion composite modified glassy carbon electrode for the detection of fenitrothion
    Kumaravel, A.
    Chandrasekaran, M.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 650 (02) : 163 - 170
  • [32] Voltammetric determination of hydrogen peroxide using MoS2 modified glassy carbon electrodes
    Haritha, V. S.
    Vijayan, Athira
    Kumar, S. R. Sarath
    Rakhi, R. B.
    MATERIALS LETTERS, 2021, 301
  • [33] Use of a Nafion-modified electrode for the voltammetric determination and speciation of lead in human whole blood
    Ibanez, JCV
    Lorente, MMF
    Suarez, JRC
    QUIMICA ANALITICA, 1998, 17 (02): : 95 - 103
  • [34] Fabrication of MWCNT-nickel MOF modified glassy carbon electrode for voltammetric determination of levofloxacin
    Fouladgar, Masoud
    Samimi, Reza
    Fathy, Zohre
    Hassanpour, Parham
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2025, 29 (01) : 341 - 349
  • [35] Pulse anodic stripping voltammetric determination of copper with an amoxicillin–nafion modified glassy carbon electrode
    A. A. Ramadan
    H. Mandil
    M. A. Saleh
    Journal of Applied Electrochemistry, 2008, 38 : 1715 - 1720
  • [36] Differential-pulse voltammetric determination of clenbuterol in bovine urine using a nafion-modified carbon paste electrode
    Moane, S
    Smyth, MR
    OKeeffe, M
    ANALYST, 1996, 121 (06) : 779 - 784
  • [37] Adsorption stripping voltammetry of phenol at Nafion-modified glassy carbon electrode in the presence of surfactants
    Yi, HC
    Wu, KB
    Hu, SS
    Cui, DF
    TALANTA, 2001, 55 (06) : 1205 - 1210
  • [38] Highly Sensitive and Selective Voltammetric Sensor Fullerene Modified Glassy Carbon Electrode for Determination of Cefitizoxime in Solubilized System
    Jain, Rajeev
    Rather, Jahangir Ahmad
    Dwivedi, Ashish
    Vikas
    ELECTROANALYSIS, 2010, 22 (21) : 2600 - 2606
  • [39] A Sensitive Chlorpromazine Voltammetric Sensor Based on Graphene Oxide Modified Glassy Carbon Electrode
    Tajik, Somayeh
    Beitollahi, Hadi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2019, 6 (01): : 171 - 182
  • [40] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051