TiO2/MWCNT/Nafion-Modified Glassy Carbon Electrode as a Sensitive Voltammetric Sensor for the Determination of Hydrogen Peroxide

被引:9
|
作者
de Oliveira, Rafael Henrique [1 ]
Goncalves, Daniel A. [2 ]
dos Reis, Diogo Duarte [1 ]
机构
[1] Fed Univ Mato Grosso Sul UFMS, Inst Phys, BR-79070900 Campo Grande, MS, Brazil
[2] Fed Univ Grande Dourados, Fac Exact Sci & Technol, BR-79804970 Dourados, MS, Brazil
关键词
hydrogen peroxide; electrochemical sensor; nanocomposite; cyclic voltammetry; TiO2; MWCNTs; TIO2; NANOPARTICLES; CYCLIC VOLTAMMETRY; NANOTUBE ARRAYS; NANOCOMPOSITES; NANOMATERIALS; H2O2; PERFORMANCE; REACTIVITY; GRAPHENE; MWCNTS;
D O I
10.3390/s23187732
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work we describe a straightforward approach for creating a nanocomposite comprising multiwalled carbon nanotubes (MWCNTs) and titanium dioxide (TiO2) using the hydrothermal technique, which is then characterized by scanning electron microscope (SEM), energy-dispersive X-ray spectrometer (EDS), X-ray diffraction analysis (XRD), Fourier transform infrared spectroscopy (FTIR), and thermal gravimetric analysis (TGA) to assess its properties. Nafion is employed as a reticular agent for the nanocomposite on the glassy carbon electrode (GCE), creating the MWCNT/TiO2/Nafion/GCE system. The electrochemical behavior of the system was evaluated using cyclic voltammetry, revealing its remarkable electrocatalytic activity for detecting hydrogen peroxide in water. The developed sensor showcased a broad linear response range of 14.00 to 120.00 mu M, with a low detection limit of 4.00 mu M. This electrochemical sensor provides a simple and highly sensitive method for detecting hydrogen peroxide in aqueous solutions and shows promising potential for various real-world applications, particularly in H2O2 monitoring.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Zhao, Fangyuan
    Wang, Fei
    Zhao, Weining
    Zhou, Jing
    Liu, Yang
    Zou, Lina
    Ye, Baoxian
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 383 - 390
  • [22] A glassy carbon electrode modified with FeS nanosheets as a highly sensitive amperometric sensor for hydrogen peroxide
    Jin, Jiayi
    Wu, Wenqin
    Min, Hui
    Wu, Huimin
    Wang, Shengfu
    Ding, Yu
    Yang, Shuijin
    MICROCHIMICA ACTA, 2017, 184 (05) : 1389 - 1396
  • [23] A glassy carbon electrode modified with FeS nanosheets as a highly sensitive amperometric sensor for hydrogen peroxide
    Jiayi Jin
    Wenqin Wu
    Hui Min
    Huimin Wu
    Shengfu Wang
    Yu Ding
    Shuijin Yang
    Microchimica Acta, 2017, 184 : 1389 - 1396
  • [24] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Li, Yamin
    Wu, Shufang
    Luo, Peili
    Liu, Jie
    Song, Ge
    Zhang, Kai
    Ye, Baoxian
    ANALYTICAL SCIENCES, 2012, 28 (05) : 497 - 502
  • [25] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Yamin Li
    Shufang Wu
    Peili Luo
    Jie Liu
    Ge Song
    Kai Zhang
    Baoxian Ye
    Analytical Sciences, 2012, 28 : 497 - 502
  • [26] Electrochemical sensor for formaldehyde based on Pt-Pd nanoparticles and a Nafion-modified glassy carbon electrode
    Zhou, Zhong-Liang
    Kang, Tian-Fang
    Zhang, Yan
    Cheng, Shui-Yuan
    MICROCHIMICA ACTA, 2009, 164 (1-2) : 133 - 138
  • [27] Sensitive Electrochemical Determination of Oxcarbazepine using MWCNT Modified Glassy Carbon Electrode
    Ershad, Sohrab
    Sani, Mahnaz Akbari
    Hosseinzadeh, Mehdi
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (08): : 637 - 649
  • [28] MWCNT-CTAB modified glassy carbon electrode as a sensor for the determination of paracetamol
    Gowda, Jayant I.
    Gunjiganvi, Danavva G.
    Sunagar, Nagaveni B.
    Bhat, Manjushree N.
    Nandibewoor, Sharanappa T.
    RSC ADVANCES, 2015, 5 (61): : 49045 - 49053
  • [29] Electrochemical Sensor Based on TiO2 Nanoparticles/Nafion Biocompatible Film Modified Glassy Carbon Electrode for Carbamazepine Determination in Pharmaceutical and Urine Samples
    Tarahomi, Somayeh
    Rounaghi, Gholam Hossein
    Zavar, Mohammad Hossein Arbab
    Daneshvar, Leili
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (16) : B946 - B952
  • [30] Highly sensitive determination of epinephrine by a MnO2/Nafion modified glassy carbon electrode
    Liu, Xiaojuan
    Ye, Daixin
    Luo, Liqiang
    Ding, Yaping
    Wang, Yulong
    Chu, Yuliang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 665 : 1 - 5