Noninvasive blood pressure measurement in patients with continuous-flow left ventricular assist devices

被引:1
|
作者
Tanaka, Aiko [1 ]
Kiriyama, Yuki [2 ]
Kubo, Naoko [1 ]
Sakaguchi, Ryota [1 ]
Uchiyama, Akinori [1 ]
Fujino, Yuji [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Anesthesiol & Intens Care Med, 2-15 Yamadaoka, Suita, Osaka 5650871, Japan
[2] Natl Org Osaka Natl Hosp, Div Anesthesiol, Chuo Ku, 2-1-14 Hoenzaka, Osaka 5400006, Japan
关键词
Blood pressure; Noninvasive measurement; Left ventricular assist device; Doppler ultrasound;
D O I
10.1007/s10047-022-01349-w
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Oscillatory blood pressure (OBP) with a slow cuff-deflation system has been proposed as noninvasive measurement of mean arterial pressure (MAP) in patients with continuous-flow left ventricular assist devices (LVADs). However, the challenge is that the measurement is not obtainable in certain patients. We hypothesized that the combined use of color Doppler imaging during OBP measurement (CDBP) could derive MAP accurately. We conducted a prospective observational study in critically ill patients (30 patients with continuous-flow LVADs and 30 control patients without LVADs). Triplicate OBP and CDBP measurements were performed and invasive blood pressure (IBP) was recorded. The overall success rate of OBP was 63.3% in the LVAD group and 98.9% in the control group. The CDBP was successfully obtained in 100% of all study patients. The CDBP in the LVAD group was closest to the MAP of measured IBP, while that in the control group was closest to the systolic IBP. The mean absolute differences in OBP and CDBP from the closest IBP were similar in both the control and LVAD groups. In nonpulsatile LVAD patients with a pulse pressure IBP < 10 mmHg, the success rate of OBP measurement was only 10.0%, and CDBP showed significantly reduced error in MAP measurement (mean absolute difference: OBP 23.2 +/- 8.7 vs CDBP 5.2 +/- 3.6 mmHg, p < 0.001). The validity of OBP measurement with a slow cuff-deflation system limited particularly in nonpulsatile LVAD patients. The concurrent use of color Doppler imaging is encouraged for more accurate measurement of MAP in patients with continuous-flow LVADs.
引用
收藏
页码:160 / 164
页数:5
相关论文
共 50 条
  • [31] Intravenous Iron Repletion in Patients With Continuous-Flow Left Ventricular Assist Devices
    Bernier, Thomas D.
    Stern, Gretchen
    Buckley, Leo F.
    Vieira, Jefferson L.
    Siddiqi, Hasan K.
    Mehra, Mandeep R.
    ASAIO JOURNAL, 2023, 69 (03) : E115 - E117
  • [32] Benefits of Neurohormonal Therapy in Patients With Continuous-Flow Left Ventricular Assist Devices
    Yousefzai, Rayan
    Brambatti, Michela
    Tran, Hao A.
    Pedersen, Rachel
    Braun, Oscar O.
    Baykaner, Tina
    Ghashghaei, Roxana
    Sulemanjee, Nasir Z.
    Cheema, Omar M.
    Rappelt, Matthew
    Baeza, Carmela
    Alkhayyat, Abdulaziz
    Shi, Yang
    Pretorius, Victor
    Greenberg, Barry
    Adler, Eric
    Thohan, Vinay
    ASAIO JOURNAL, 2020, 66 (04) : 409 - 414
  • [33] Hematologic disorders and continuous-flow left ventricular assist devices
    Connors, Jean M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (11): : 1114 - 1116
  • [34] Factor Xa inhibitors in patients with continuous-flow left ventricular assist devices
    Vishal Y. Parikh
    Umang M. Parikh
    Angel Moctezuma-Ramirez
    Harveen K. Lamba
    Joggy K. George
    Savitri Fedson
    Ajith P. Nair
    O. H.  Frazier
    Reynolds M. Delgado
    General Thoracic and Cardiovascular Surgery, 2020, 68 : 1278 - 1284
  • [35] Transmission of Pulsatility Into the Brain of Patients with Continuous-Flow Left Ventricular Assist Devices
    Stohr, E. J.
    Castagna, F.
    Pinsino, A.
    Cockcroft, J. R.
    Yuzefpolskaya, M.
    Garan, A. R.
    Topkara, V. K.
    Takayama, H.
    Takeda, K.
    Naka, Y.
    Colombo, P. C.
    Willey, J. Z.
    McDonnell, B. J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S284 - S284
  • [36] Continuous-flow left ventricular assist devices induce Left ventricular reverse remodeling
    Jacobs, Steven
    Geens, Jef
    Rega, Filip
    Burkhoff, Daniel
    Meyns, Bart
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : 466 - 468
  • [37] Pulse assessment is important with blood pressure measurement in individuals with continuous flow left ventricular assist devices
    Marcos-Abdala, Hernan G.
    Cruz-Solbes, Ana S.
    Hussain, Imad
    Trachtenberg, Barry
    Ashrith, Guha
    Torre-Amione, Guillermo
    Bruckner, Brian
    Suarez, Erik E.
    Estep, Jerry D.
    Bhimaraj, Arvind
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2021, 44 (02): : 124 - 129
  • [38] Ventricular arrhythmias do not affect prognosis in patients with continuous-flow left ventricular assist devices
    Koenig, T.
    Heimeshoff, J.
    Duncker, D.
    Schmitto, J.
    Veltmann, C.
    EUROPEAN HEART JOURNAL, 2017, 38 : 234 - 234
  • [39] Ventricular reconditioning and pump explantation in patients supported by continuous-flow left ventricular assist devices
    Frazier, O. H.
    Baldwin, Andrew C. W.
    Demirozu, Zumrut T.
    Segura, Ana Maria
    Hernandez, Ruben
    Taegtmeyer, Heinrich
    Mallidi, Hari
    Cohn, William E.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (06): : 766 - 772
  • [40] Catheter Ablation for Ventricular Tachyarrhythmias in Patients Supported by Continuous-Flow Left Ventricular Assist Devices
    Garan, Arthur R.
    Iyer, Vivek
    Whang, William
    Mody, Kanika P.
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Te-Frey, Rosie
    Takayama, Hiroo
    Naka, Yoshifumi
    Garan, Hasan
    Jorde, Ulrich P.
    Uriel, Nir
    ASAIO JOURNAL, 2014, 60 (03) : 311 - 316