SMOKE DETECTOR PLACEMENT IN COMPARTMENTS WITH HONEYCOMB CEILING A Numerical Study

被引:0
|
作者
Zigar, Darko N. [1 ]
Blagojevic, Milan Dj. [1 ]
Pesic, Dusica J. [1 ]
Bozilov, Aca V. [2 ]
Nikolic, Vlastimir D. [2 ]
机构
[1] Univ Nis, Fac Occupat Safety, Nish, Serbia
[2] Univ Nis, Fac Mech Engn, Nish, Serbia
来源
THERMAL SCIENCE | 2023年 / 27卷 / 3B期
关键词
honeycomb ceiling; fire detection; fire dynamics dimulator; simulation; smoke detector location;
D O I
10.2298/TSCI220819205Z
中图分类号
O414.1 [热力学];
学科分类号
摘要
One of the most interesting problems in fire detection system design is the problem referred to as detector position on a 'honeycomb ceiling', because beams and joists affect stratification of smoke and, consequently, smoke detector response time. The aim of this paper is to determine optimal smoke detector placement - on the underside of beams or on the structural slab in the cells. On the basis of rules of standards for smoke detector location, the large eddy simulation method of fire dynamics simulator software package was employed to investigate the effects of 'honeycomb'density on smoke detector response time. The simulation results show that the columns, beams, joists and similar structural elements affect stratification of smoke and, consequently, smoke detector response time. In the case when the honeycomb cells are small, the detectors on the underside of the beams react faster because the smoke does not enter the cells in sufficient quantity to activate the optical smoke detector located on the structural plate in the cells that form the beams. On the basis of the obtained results, a satisfactory solution for most possible situations that could occur in practice has been proposed.
引用
收藏
页码:2489 / 2500
页数:12
相关论文
共 50 条
  • [41] STUDY ON DESIGN OPTIMIZATION OF FIRE SMOKE CONTROL MODES FOR SUBWAY TRANSFER CHANNEL WITH CEILING BEAMS
    Tian, Xiangliang
    Liu, Chang
    Zhong, Maohua
    PROCEEDINGS OF THE ASME 2020 HEAT TRANSFER SUMMER CONFERENCE (HT2020), 2020,
  • [42] Numerical simulation and test study on honeycomb structure with embedded stringers
    Yang, Yanzhi
    Song, Linyu
    Wang, Ruifeng
    Wang, Yong
    Jin, Yulong
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2014, 31 (04): : 1072 - 1076
  • [43] Numerical study on lateral-torsional buckling of honeycomb beam
    Gunawan, Danny
    Suryoatmono, Bambang
    3RD INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS - SUSTAINABLE STRUCTURES FOR FUTURE GENERATIONS, 2017, 171 : 140 - 146
  • [44] Flexural Damage of Honeycomb Paperboard-A Numerical and Experimental Study
    Czechowski, Leszek
    Smiechowicz, Wojciech
    Kmita-Fudalej, Gabriela
    Szewczyk, Wlodzimierz
    MATERIALS, 2020, 13 (11)
  • [45] Experimental study on ceiling smoke temperature distributions in near field of pool fires in the subway train
    Peng, Min
    Cheng, Xudong
    He, Kun
    Cong, Wei
    Shi, Long
    Yuen, Richard
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2020, 199
  • [46] Buoyancy-driven flow through a ceiling aperture in a corridor: A study on smoke propagation and prevention
    Bosi Zhang
    Jiaqing Zhang
    Shouxiang Lu
    Changhai Li
    Building Simulation, 2015, 8 : 701 - 709
  • [47] NUMERICAL STUDY OF CURRENTS AND FIELDS IN A PHOTOCONDUCTIVE DETECTOR
    PETERSON, RL
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1987, 23 (07) : 1185 - 1192
  • [48] Numerical study on the influence of steam condensation on hydrogen distribution in local compartments
    Wang, D.
    Tong, L.
    Cao, X.
    ANNALS OF NUCLEAR ENERGY, 2018, 121 : 468 - 478
  • [49] Numerical Simulation Study of Smoke Exhaust Efficiency in an Atrium
    Zhou, Dechuang
    Wang, Jian
    He, Yaping
    JOURNAL OF FIRE PROTECTION ENGINEERING, 2010, 20 (02) : 117 - 142
  • [50] Experimental and numerical study on the smoke movement and smoke control strategy in a hub station fire
    Liu, Fang
    Liu, Yongqiang
    Xiong, Kang
    Weng, Miaocheng
    Wang, Jun
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 96