One of the most interesting problems in fire detection system design is the problem referred to as detector position on a 'honeycomb ceiling', because beams and joists affect stratification of smoke and, consequently, smoke detector response time. The aim of this paper is to determine optimal smoke detector placement - on the underside of beams or on the structural slab in the cells. On the basis of rules of standards for smoke detector location, the large eddy simulation method of fire dynamics simulator software package was employed to investigate the effects of 'honeycomb'density on smoke detector response time. The simulation results show that the columns, beams, joists and similar structural elements affect stratification of smoke and, consequently, smoke detector response time. In the case when the honeycomb cells are small, the detectors on the underside of the beams react faster because the smoke does not enter the cells in sufficient quantity to activate the optical smoke detector located on the structural plate in the cells that form the beams. On the basis of the obtained results, a satisfactory solution for most possible situations that could occur in practice has been proposed.
引用
收藏
页码:2489 / 2500
页数:12
相关论文
共 50 条
  • [31] Numerical research on the smoke spread process of thin-tall atrium space under various ceiling height
    Xu, Lei
    Wang, Yongyu
    Song, Liwei
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 25
  • [32] NUMERICAL STUDY OF STRATIFICATION OF A SMOKE LAYER IN A CORRIDOR
    BOS, WG
    VANDENELSEN, T
    HOOGENDOORN, CJ
    TEST, FL
    COMBUSTION SCIENCE AND TECHNOLOGY, 1984, 38 (5-6) : 227 - 243
  • [33] A first approximation method for smoke detector placement based on design fire size critical velocity, and detector aerosol entry lag time
    Brozovsky, E
    Motevalli, V
    Custer, RLP
    FIRE TECHNOLOGY, 1995, 31 (04) : 336 - 354
  • [34] Numerical Study of Discharge Coefficients for Side-Damaged Compartments
    Tian, Siwen
    Peng, Fei
    Wang, Zhanzhi
    Li, Jingda
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2024, 12 (09)
  • [35] THE study of aspirating smoke detector system with fire dynamics simulator
    Cheng, Shao-Tsai
    Gong, Chau-Yu
    Journal of Technology, 2015, 30 (02): : 73 - 82
  • [36] Study on calibration method of filter for linear beam smoke detector
    Yao, Yao
    Tian Yuyu
    Peng, Cheng
    AOPC 2022: OPTOELECTRONICS AND NANOPHOTONICS, 2022, 12556
  • [37] Smoke detector response and the use of antistatic materials: An empirical study
    Qualey, JR
    Penney, S
    FIRE TECHNOLOGY, 2005, 41 (04) : 215 - 234
  • [38] Smoke Detector Response and the Use of Antistatic Materials: An Empirical Study
    J. R. Qualey
    S. Penney
    Fire Technology, 2005, 41 : 215 - 234
  • [39] Numerical Study of a Ventilated Room: Effect of Heating Floor and Cooling Ceiling
    Khattari, Youness
    Benghoulam, Mahjoub
    Arid, Ahmed
    Elrhafiki, Tank
    PROCEEDINGS OF 2017 INTERNATIONAL RENEWABLE & SUSTAINABLE ENERGY CONFERENCE (IRSEC' 17), 2017, : 974 - 979
  • [40] Buoyancy-driven flow through a ceiling aperture in a corridor: A study on smoke propagation and prevention
    Zhang, Bosi
    Zhang, Jiaqing
    Lu, Shouxiang
    Li, Changhai
    BUILDING SIMULATION, 2015, 8 (06) : 701 - 709