Uncertainty of Quantitative X-ray Fluorescence Micro-Analysis of Metallic Artifacts Caused by Their Curved Shapes

被引:6
|
作者
Trojek, Tomas [1 ]
Trojkova, Darina [1 ]
机构
[1] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Dept Dosimetry & Applicat Ionizing Radiat, Brehova 7, Prague 11519, Czech Republic
关键词
X-ray fluorescence; quantitative analysis; metal; Monte Carlo method; NONDESTRUCTIVE ANALYSIS; ART; SPECTROMETRY; PAINTINGS; XRF;
D O I
10.3390/ma16031133
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper summarizes the effects of irregular shape on the results of a quantitative X-ray fluorescence (XRF) micro-analysis. These effects become relevant when an XRF analysis is performed directly on an investigated material. A typical example is XRF analyses of valuable and historical objects whose measurements should be performed non-destructively and non-invasively, without taking samples. Several measurements and computer simulations were performed for selected metallic materials and shapes to evaluate the accuracy and precision of XRF. The described experiments and the corresponding Monte Carlo simulations were related to the XRF device designed and utilized at the Czech Technical University. It was found that the relative uncertainty was typically about 5-10% or even higher in quantitative analyses of minor elements due to irregular shapes of surfaces. This must be considered in cases of the interpretation of XRF results, especially in the cultural heritage sciences. The conclusions also contain several recommendations on how to measure objects under hard-to-define geometric conditions with respect to reduction in the surface effect in quantitative or semi-quantitative XRF analyses.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Research in quantitative microscopic X-ray fluorescence analysis
    Lankosz, M
    Szczerbowska-Boruchowska, M
    Chwiej, J
    Ostachowicz, J
    Simionovici, A
    Bohic, S
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (10-11) : 1517 - 1521
  • [32] Polychromatic and Microfocused X-ray Radiation for Traceable Quantitative X-ray Fluorescence Analysis
    Kayser, Yves
    Unterumsberger, Rainer
    Waehlisch, Andre
    Bzheumikhova, Karina
    Hoenicke, Philipp
    Zech, Claudia
    Beckhoff, Burkhard
    SPECTROSCOPY, 2021, 36 : 13 - 16
  • [33] Quantitative x-ray micro-analysis of choroidal lymph in chick during recovery from form-deprivation myopia
    Junghans, BM
    Wadley, RB
    Liang, H
    Crewther, SG
    Crewther, DP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S451 - S451
  • [35] Distribution analysis of carbonyl groups in a polymer by derivatization/electron probe X-ray micro-analysis
    Sugiura, M
    Tsuji, M
    Murase, A
    Mitsuoka, T
    BUNSEKI KAGAKU, 1999, 48 (11) : 983 - 988
  • [36] Distribution analysis of carboxyl groups in polymer by a derivatization/electron probe X-ray micro-analysis
    Murase, A
    Mitsuoka, T
    Sugiura, M
    Araga, T
    BUNSEKI KAGAKU, 1997, 46 (01) : 37 - 43
  • [37] Fundamental characteristics of hybrid X-ray focusing optics for micro X-ray fluorescence analysis
    Komatani, Shintaro
    Nakamachi, Kazuo
    Nakano, Kazuhiko
    Ohzawa, Sumito
    Uchihara, Hiroshi
    Bando, Atsushi
    Tsuji, Kouichi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 309 : 260 - 263
  • [38] X-ray micro-analysis of a cirripede adapted to life in hydrothermal vents in the West Pacific
    Klepal, W
    Weidinger, M
    Tufar, W
    EUROPEAN JOURNAL OF CELL BIOLOGY, 1997, 74 : 100 - 100
  • [39] Micro total reflection x-ray fluorescence (μ-TXRF) analysis
    Tsuji, Kouichi
    Kawamata, Masaya
    Nishida, Yousuke
    Nakano, Kazuhiko
    Sasaki, Ken-ichi
    X-RAY SPECTROMETRY, 2006, 35 (06) : 375 - 378
  • [40] AN EVALUATION OF X-RAY TUBE SPECTRA FOR QUANTITATIVE X-RAY-FLUORESCENCE ANALYSIS
    MURATA, M
    SHIBAHARA, H
    X-RAY SPECTROMETRY, 1981, 10 (01) : 41 - 45