Uncertainty of Quantitative X-ray Fluorescence Micro-Analysis of Metallic Artifacts Caused by Their Curved Shapes

被引:6
|
作者
Trojek, Tomas [1 ]
Trojkova, Darina [1 ]
机构
[1] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Dept Dosimetry & Applicat Ionizing Radiat, Brehova 7, Prague 11519, Czech Republic
关键词
X-ray fluorescence; quantitative analysis; metal; Monte Carlo method; NONDESTRUCTIVE ANALYSIS; ART; SPECTROMETRY; PAINTINGS; XRF;
D O I
10.3390/ma16031133
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper summarizes the effects of irregular shape on the results of a quantitative X-ray fluorescence (XRF) micro-analysis. These effects become relevant when an XRF analysis is performed directly on an investigated material. A typical example is XRF analyses of valuable and historical objects whose measurements should be performed non-destructively and non-invasively, without taking samples. Several measurements and computer simulations were performed for selected metallic materials and shapes to evaluate the accuracy and precision of XRF. The described experiments and the corresponding Monte Carlo simulations were related to the XRF device designed and utilized at the Czech Technical University. It was found that the relative uncertainty was typically about 5-10% or even higher in quantitative analyses of minor elements due to irregular shapes of surfaces. This must be considered in cases of the interpretation of XRF results, especially in the cultural heritage sciences. The conclusions also contain several recommendations on how to measure objects under hard-to-define geometric conditions with respect to reduction in the surface effect in quantitative or semi-quantitative XRF analyses.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] X-ray fluorescence imaging of ancient artifacts
    Thorne, Robert E.
    Geil, Ethan C.
    Hudson, Kathryn
    Clinton, Kevin
    Crowther, Charles
    Dale, Darren
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2011, 67 : C762 - C762
  • [22] Analysis of metallic archaeological artifacts by x-ray computed microtomography technique
    Machado, A. S.
    Silva, A. S. S.
    Campos, G. N.
    Gomes, C. S.
    Oliveira, D. F.
    Lopes, R. T.
    APPLIED RADIATION AND ISOTOPES, 2019, 151 : 274 - 279
  • [23] Statistical artifacts: Critical approaches to the analysis of obsidian artifacts by portable X-ray fluorescence
    Stroth, Luke
    Otto, Raquel
    Daniels, James T., Jr.
    Braswell, Geoffrey E.
    JOURNAL OF ARCHAEOLOGICAL SCIENCE-REPORTS, 2019, 24 : 738 - 747
  • [24] HIGH-SPEED X-RAY MICRO-ANALYSIS USING IMAGE ANALYSIS TECHNIQUES
    JEFFREY, J
    COWHAM, MJ
    MICROSCOPE, 1972, 20 (03): : 298 - &
  • [25] Shedding Electrons on Cenospheres: Advancing Characterization Through X-ray Micro-Analysis
    Kanesalingam, Brinthan
    Fernando, W. Ashane M.
    Jayawardena, Chulantha
    Attygalle, Dinesh
    Amarasinghe, D. A. S.
    Rabbani, Arash
    Panda, Sandeep
    CHEMISTRYSELECT, 2025, 10 (01):
  • [26] Quantification procedures in micro X-ray fluorescence analysis
    Kanngiesser, B
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (04) : 609 - 614
  • [27] Capillary optics for micro x-ray fluorescence analysis
    Bjeoumikhov, A
    Langhoff, N
    Bjeoumikhova, S
    Wedell, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (06):
  • [28] X-ray tube spectral measurement method for quantitative analysis of X-ray fluorescence analysis
    Sasaki, Nobuharu
    Okada, Kennji
    Kawai, Jun
    X-RAY SPECTROMETRY, 2010, 39 (05) : 328 - 331
  • [29] Artifacts in Qualititative and Quantitative X-Ray Mapping
    Wuhrer, Richard
    Moran, Ken
    MICROSCOPY AND MICROANALYSIS, 2009, 15 : 30 - 31
  • [30] QUANTITATIVE FLUORINE DETERMINATION BY X-RAY FLUORESCENCE ANALYSIS
    JECHT, U
    CHEMIKER-ZEITUNG, 1972, 96 (02): : 104 - &