Numerical study on the airflow characteristics and smoke control condition in stair area of subway stations

被引:2
|
作者
Chen, Junfeng [1 ]
Li, Guoqin [2 ]
Pan, Rongliang [1 ]
Long, Zeng [1 ]
Zhong, Maohua [1 ,3 ]
机构
[1] Tsinghua Univ, Inst Publ Safety Res, Dept Engn Phys, Beijing 100084, Peoples R China
[2] Beijing Urban Construct Design & Dev Grp Co Ltd, Beijing 100034, Peoples R China
[3] Tsinghua Univ, Ltd Joint Res Ctr Urban Disaster Prevent & Safety, Dept Engn Phys, Beijing Urban Construct Design & Dev Grp Co, Beijing 100084, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Subway station; Stair; Fire smoke; Airflow; Mechanical ventilation; VENTILATION MODE; VIRTUAL ORIGINS; SMALL OPENINGS; FIRE; PLATFORM; OPTIMIZATION; TEMPERATURE; EMERGENCY; TRAIN;
D O I
10.1016/j.jobe.2024.108577
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As the key facility connecting different floors in subway stations, the smoke control in the stair area has been one of the most important goals of fire protection design. But the detailed airflow field and smoke spread process are rarely discussed. With numerical simulation, this work investigated the airflow velocity distribution and critical condition for smoke control in two critical openings of the stair area, which include the opening beneath the ceiling screen and the opening on the top of the stair. The results indicate that (1) In spatial dimension, the airflow velocity distribution shows a nonuniformity within each opening and a difference between two openings. (2) In the temporal dimension, the airflow velocity shows a normal distribution characteristic. The strong turbulence leads to a dynamic airflow field with an unstable smoke spread process. (3) For the critical opening beneath the ceiling screen, the airflow velocity is dominated by thermal buoyancy or inertia force in different areas. The practical smoke control criterion is to ensure the smoke layer is higher than the edge of the ceiling screen. (4) For the critical opening on the top of the stair, airflow velocity shows an exponential decay distribution. The critical condition could be predicted with a virtual fire source within the stair. This work hopes to present the necessity of dynamic and microscopic modeling of the airflow - smoke flow interaction for an accurate prediction of the smoke control condition in the stair area of subway stations.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] NUMERICAL STUDY OF SMOKE PROPAGATION IN A SIMULATED FIRE IN A WAGON WITHIN A SUBWAY TUNNEL
    Vittori, Felipe
    Rojas-Solorzano, Luis
    Blanco, Armando J.
    Urbina, Rafael
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER CONFERENCE -2008, VOL 1, PT A AND B, 2009, : 1017 - 1024
  • [22] Numerical study on the optimisation of smoke ventilation mode for interchange subway station fire
    Zhao, Dong
    Jiang, Juncheng
    Zhou, Ru
    Tong, Yan
    Wu, Fan
    Shi, Langjun
    INTERNATIONAL JOURNAL OF VENTILATION, 2016, 15 (01) : 79 - 93
  • [23] Numerical study of the characteristics of smoke spread in tunnel fires during construction and method for improvement of smoke control
    Yao, Yongzheng
    Wang, Rui
    Xia, Ziyang
    Ren, Fei
    Zhao, Jinlong
    Zhu, Hongqing
    Cheng, Xudong
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 34
  • [24] Case study of train-induced airflow inside underground subway stations with simplified field test methods
    Yang, Le
    Zhang, Yichi
    Xia, Jianjun
    SUSTAINABLE CITIES AND SOCIETY, 2018, 37 : 275 - 287
  • [25] Shaking-table tests and numerical simulations study of subway stations in loess region
    Xiong, Ergang
    Gao, Yuan
    Cao, Tao
    Wang, Wenxiang
    STRUCTURES, 2024, 69
  • [26] Numerical study on the optimization of smoke ventilation mode at the conjunction area between tunnel track and platform in emergency of a train fire at subway station
    Meng, Na
    Hu, Longhua
    Wu, Long
    Yang, Lizhong
    Zhu, Shi
    Chen, Longfei
    Tang, Wei
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2014, 40 : 151 - 159
  • [27] Study on the critical velocity for smoke control in a subway tunnel cross-passage
    Feng, Shan
    Li, Yanfeng
    Hou, Yusheng
    Li, Junmei
    Huang, Youbo
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 97
  • [28] Scale modeling and numerical simulation of smoke control for rescue stations in long railway tunnels
    Li, Ying Zhen
    Lei, Bo
    Ingason, Haukur
    JOURNAL OF FIRE PROTECTION ENGINEERING, 2012, 22 (02) : 101 - 131
  • [29] Experimental and numerical study of space station airflow distribution under microgravity condition
    Wang, Congcong
    Liu, Junjie
    Shang, Wenjin
    Sun, Hejiang
    Li, Jiayu
    Fan, Fenghua
    BUILDING AND ENVIRONMENT, 2018, 144 : 268 - 280
  • [30] Experimental study on the characteristics of vibration energy propagation in the subway turnout area
    Gao, Xin
    Yi, Qiang
    Lei, Jiaxin
    Wang, Ping
    Zhao, Caiyou
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 409